November 15, 2026 · R25–R29 working issue
Measured design review and current full 3D
Current corrections are available for review. No new design image/native render, owner approval or construction authorization was created. The bathroom boundary discrepancy, source/detail and operation gaps remain open. Oriel is preferred pending Nada; Option C is a separate fallback. The larger upholstered chair/floated loveseat and default alcohol bar remain the starting preference.
Download the 26-page draft measurement book · Download frozen sampling, observations and reproducible observers · Draft coordination questions
Actual geometry checked
In every state: 35 tagged frame envelopes, 38 glazing/view apertures, 14 furniture instances and 11 typed room chains pass their declared checks. Forty-one reported-defect/steel/chair/CW controls pass; five controls in that observer remain unverifiable. All five building shells are identical. These scoped results do not establish whole-space source or operation qualification.
460 frozen T1/T2/T3/T9 diagnostics cover 23 room scopes in five states. All remain held. The original W104 source-observer failure and corrected same-draw receipts are both retained. No statistical whole-house claim is made. Image stages T4–T6 remain unrun; browser/export T7 and property-registration T8 need separate evidence.
Go through each area
Bedroom 1 · Chris
Source/model qualification: HELD. No new image authorized.
Primary context: A102 p85, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).
- Architectural Bedroom1 is Chris; Meghan concept Bedroom2. Manufacturer/fixture positions are design studies; bedroom gas decision remains open.
Room evidence JSON
{
"id": "bedroom1",
"title": "Bedroom 1 · Chris",
"level": "main",
"source_aliases": [
"Chris bedroom",
"Meghan concept Bedroom2"
],
"primary_plan_context": [
{
"sheet": "A102",
"page": 85
},
{
"sheet": "A103",
"page": 86
},
{
"sheet": "A200",
"page": 87
},
{
"sheet": "A201",
"page": 88
},
{
"sheet": "A300",
"page": 89
},
{
"sheet": "S103",
"page": 95
},
{
"sheet": "S200",
"page": 96
},
{
"sheet": "S301",
"page": 98
}
],
"primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
"Meghan_concept_pages": [
8
],
"Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
"current_opening_units": [
"W105",
"W106",
"E100",
"TW100",
"TW101",
"TW102"
],
"adjoining_wall_inventory": [
"bed-east",
"bed1-south-partition",
"bed-north",
"hall-west",
"nook-south"
],
"wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
"ceiling_controls": [
{
"id": "bedroom1.main-ceiling",
"room": "bedroom1",
"level": "main",
"plane_world_z_equals_ax_by_c": [
0.08333333333333333,
0,
267.511666666667
],
"quantity_type": "finished ceiling underside",
"basis": "Shared source-registered A103/A300bedroom-wing R2slope; independent132.125/151.375in source stations and1:12pitch.",
"source_class": "Primary source registered nominal plane",
"not_room_boundary": false,
"additional_regions": null
}
],
"later_changes_and_reconciliation": [
"Architectural Bedroom1 is Chris; Meghan concept Bedroom2. Manufacturer/fixture positions are design studies; bedroom gas decision remains open."
],
"model_census_by_state": {
"alcohol": {
"faces": 2088,
"object_records": 16
},
"espresso": {
"faces": 2088,
"object_records": 16
},
"espresso-open": {
"faces": 2088,
"object_records": 16
},
"alcohol-open": {
"faces": 2088,
"object_records": 16
},
"espresso-operating": {
"faces": 2088,
"object_records": 16
}
},
"source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
"transitions": {
"T1": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T2": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T3": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T4": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T5": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T6": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T7": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T8": {
"status": "held",
"reason": "Property transform/field levels unmeasured"
},
"T9": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
}
},
"whole_space_qualified": false,
"image_generation_allowed": false,
"owner_approval": null
}Bedroom 2 · Michelle
Source/model qualification: HELD. No new image authorized.
Primary context: A102 p85, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).
- Architectural Bedroom2 is Michelle; Meghan concept Bedroom1. Current nominal finished219.875x156in replaces the oversized old core-only room.
Room evidence JSON
{
"id": "bedroom2",
"title": "Bedroom 2 · Michelle",
"level": "main",
"source_aliases": [
"Michelle bedroom",
"Meghan concept Bedroom1"
],
"primary_plan_context": [
{
"sheet": "A102",
"page": 85
},
{
"sheet": "A103",
"page": 86
},
{
"sheet": "A200",
"page": 87
},
{
"sheet": "A201",
"page": 88
},
{
"sheet": "A300",
"page": 89
},
{
"sheet": "S103",
"page": 95
},
{
"sheet": "S200",
"page": 96
},
{
"sheet": "S301",
"page": 98
}
],
"primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
"Meghan_concept_pages": [
7
],
"Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
"current_opening_units": [
"W100",
"W101",
"W102"
],
"adjoining_wall_inventory": [
"bed-east",
"bed-south",
"bed2-west",
"bed2-south-partition",
"hall-west",
"powder-boot-south"
],
"wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
"ceiling_controls": [
{
"id": "bedroom2.main-ceiling",
"room": "bedroom2",
"level": "main",
"plane_world_z_equals_ax_by_c": [
0.08333333333333333,
0,
267.511666666667
],
"quantity_type": "finished ceiling underside",
"basis": "Shared source-registered A103/A300bedroom-wing R2slope; independent132.125/151.375in source stations and1:12pitch.",
"source_class": "Primary source registered nominal plane",
"not_room_boundary": false,
"additional_regions": null
}
],
"later_changes_and_reconciliation": [
"Architectural Bedroom2 is Michelle; Meghan concept Bedroom1. Current nominal finished219.875x156in replaces the oversized old core-only room."
],
"model_census_by_state": {
"alcohol": {
"faces": 1518,
"object_records": 13
},
"espresso": {
"faces": 1518,
"object_records": 13
},
"espresso-open": {
"faces": 1518,
"object_records": 13
},
"alcohol-open": {
"faces": 1518,
"object_records": 13
},
"espresso-operating": {
"faces": 1518,
"object_records": 13
}
},
"source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
"transitions": {
"T1": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T2": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T3": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T4": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T5": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T6": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T7": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T8": {
"status": "held",
"reason": "Property transform/field levels unmeasured"
},
"T9": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
}
},
"whole_space_qualified": false,
"image_generation_allowed": false,
"owner_approval": null
}Primary bathroom
Source/model qualification: HELD. No new image authorized.
Primary context: A102 p85, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).
- November3 I104supersedes earlier wet/WC layouts;149.5x138in clear room, registered without scaling. Source42.875in is glass-face clearance;40.75in is half-wall floor clearance.
- Common sloped wing ceiling replaces unsupported108.4536in flat proxy. Lower wet enclosure retained.
- FAIL/coordination: I104south finishY332.35 versus earlier shellY332.47;0.12in offset remains explicit. Final tile/backing registration must reconcile; no arbitrary fixture rescale.
Room evidence JSON
{
"id": "primary-bathroom",
"title": "Primary bathroom",
"level": "main",
"source_aliases": [],
"primary_plan_context": [
{
"sheet": "A102",
"page": 85
},
{
"sheet": "A103",
"page": 86
},
{
"sheet": "A200",
"page": 87
},
{
"sheet": "A201",
"page": 88
},
{
"sheet": "A300",
"page": 89
},
{
"sheet": "S103",
"page": 95
},
{
"sheet": "S200",
"page": 96
},
{
"sheet": "S301",
"page": 98
}
],
"primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
"Meghan_concept_pages": [
6
],
"Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
"current_opening_units": [
"W103",
"W104"
],
"adjoining_wall_inventory": [
"bed-east",
"bed2-south-partition",
"bed1-south-partition",
"bath-hall-nov03",
"primary-WC-west",
"primary-WC-front"
],
"wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
"ceiling_controls": [
{
"id": "primary-bathroom.main-ceiling",
"room": "primary-bathroom",
"level": "main",
"plane_world_z_equals_ax_by_c": [
0.08333333333333333,
0,
267.511666666667
],
"quantity_type": "finished ceiling underside",
"basis": "Shared source-registered A103/A300bedroom-wing R2slope; independent132.125/151.375in source stations and1:12pitch.",
"source_class": "Primary source registered nominal plane",
"not_room_boundary": false,
"additional_regions": "GreatRoomalso has centralR1approach/side ceilings; primary bath has lower wet enclosure. Read scoped controls, not a single-room height."
}
],
"later_changes_and_reconciliation": [
"November3 I104supersedes earlier wet/WC layouts;149.5x138in clear room, registered without scaling. Source42.875in is glass-face clearance;40.75in is half-wall floor clearance.",
"Common sloped wing ceiling replaces unsupported108.4536in flat proxy. Lower wet enclosure retained.",
"FAIL/coordination: I104south finishY332.35 versus earlier shellY332.47;0.12in offset remains explicit. Final tile/backing registration must reconcile; no arbitrary fixture rescale."
],
"model_census_by_state": {
"alcohol": {
"faces": 5348,
"object_records": 113
},
"espresso": {
"faces": 5348,
"object_records": 113
},
"espresso-open": {
"faces": 5348,
"object_records": 113
},
"alcohol-open": {
"faces": 5348,
"object_records": 113
},
"espresso-operating": {
"faces": 5348,
"object_records": 113
}
},
"source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
"transitions": {
"T1": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T2": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T3": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T4": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T5": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T6": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T7": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T8": {
"status": "held",
"reason": "Property transform/field levels unmeasured"
},
"T9": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
}
},
"whole_space_qualified": false,
"image_generation_allowed": false,
"owner_approval": null
}Main hall & bedroom thresholds
Source/model qualification: HELD. No new image authorized.
Primary context: A102 p85, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).
- Later I104hall partition registration retained. Door heads/leaf/hardware fit and whole finished-floor build-up remain unconfirmed.
Room evidence JSON
{
"id": "main-hall",
"title": "Main hall & bedroom thresholds",
"level": "main",
"source_aliases": [],
"primary_plan_context": [
{
"sheet": "A102",
"page": 85
},
{
"sheet": "A103",
"page": 86
},
{
"sheet": "A200",
"page": 87
},
{
"sheet": "A201",
"page": 88
},
{
"sheet": "A300",
"page": 89
},
{
"sheet": "S103",
"page": 95
},
{
"sheet": "S200",
"page": 96
},
{
"sheet": "S301",
"page": 98
}
],
"primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
"Meghan_concept_pages": [],
"Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
"current_opening_units": [],
"adjoining_wall_inventory": [
"bed2-south-partition",
"bed1-south-partition",
"hall-west",
"powder-north",
"bath-hall-nov03"
],
"wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
"ceiling_controls": [
{
"id": "main-hall.main-ceiling",
"room": "main-hall",
"level": "main",
"plane_world_z_equals_ax_by_c": [
0.08333333333333333,
0,
267.511666666667
],
"quantity_type": "finished ceiling underside",
"basis": "Shared source-registered A103/A300bedroom-wing R2slope; independent132.125/151.375in source stations and1:12pitch.",
"source_class": "Primary source registered nominal plane",
"not_room_boundary": false,
"additional_regions": null
}
],
"later_changes_and_reconciliation": [
"Later I104hall partition registration retained. Door heads/leaf/hardware fit and whole finished-floor build-up remain unconfirmed."
],
"model_census_by_state": {
"alcohol": {
"faces": 8,
"object_records": 1
},
"espresso": {
"faces": 8,
"object_records": 1
},
"espresso-open": {
"faces": 8,
"object_records": 1
},
"alcohol-open": {
"faces": 8,
"object_records": 1
},
"espresso-operating": {
"faces": 8,
"object_records": 1
}
},
"source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
"transitions": {
"T1": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T2": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T3": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T4": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T5": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T6": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T7": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T8": {
"status": "held",
"reason": "Property transform/field levels unmeasured"
},
"T9": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
}
},
"whole_space_qualified": false,
"image_generation_allowed": false,
"owner_approval": null
}Powder room
Source/model qualification: HELD. No new image authorized.
Primary context: A102 p85, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).
- Nominal finished assemblies reconciled; vanity rigidly moved0.51in to fit. Plumbing selection and installed clearances remain open.
Room evidence JSON
{
"id": "powder-room",
"title": "Powder room",
"level": "main",
"source_aliases": [],
"primary_plan_context": [
{
"sheet": "A102",
"page": 85
},
{
"sheet": "A103",
"page": 86
},
{
"sheet": "A200",
"page": 87
},
{
"sheet": "A201",
"page": 88
},
{
"sheet": "A300",
"page": 89
},
{
"sheet": "S103",
"page": 95
},
{
"sheet": "S200",
"page": 96
},
{
"sheet": "S301",
"page": 98
}
],
"primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
"Meghan_concept_pages": [
5
],
"Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
"current_opening_units": [
"W111"
],
"adjoining_wall_inventory": [
"bed2-west",
"bed2-south-partition",
"hall-west",
"powder-boot-south",
"powder-boot",
"powder-north"
],
"wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
"ceiling_controls": [
{
"id": "powder-room.main-ceiling",
"room": "powder-room",
"level": "main",
"plane_world_z_equals_ax_by_c": [
0,
0,
256.125
],
"quantity_type": "finished ceiling underside",
"basis": "A300centralR1finished-ceiling118.125in; Muskoka underside beam is separately108.5in above main.",
"source_class": "Primary source registered nominal plane",
"not_room_boundary": false,
"additional_regions": null
}
],
"later_changes_and_reconciliation": [
"Nominal finished assemblies reconciled; vanity rigidly moved0.51in to fit. Plumbing selection and installed clearances remain open."
],
"model_census_by_state": {
"alcohol": {
"faces": 442,
"object_records": 3
},
"espresso": {
"faces": 442,
"object_records": 3
},
"espresso-open": {
"faces": 442,
"object_records": 3
},
"alcohol-open": {
"faces": 442,
"object_records": 3
},
"espresso-operating": {
"faces": 442,
"object_records": 3
}
},
"source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
"transitions": {
"T1": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T2": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T3": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T4": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T5": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T6": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T7": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T8": {
"status": "held",
"reason": "Property transform/field levels unmeasured"
},
"T9": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
}
},
"whole_space_qualified": false,
"image_generation_allowed": false,
"owner_approval": null
}Boot room / mudroom storage
Source/model qualification: HELD. No new image authorized.
Primary context: A102 p85, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).
- Stone entry finish continues through muddy-boot removal area under owner direction. E5east envelope/outward side corrected; actual printed61in clear control passes. Cabinetry is custom proposed fit.
Room evidence JSON
{
"id": "boot-room",
"title": "Boot room / mudroom storage",
"level": "main",
"source_aliases": [],
"primary_plan_context": [
{
"sheet": "A102",
"page": 85
},
{
"sheet": "A103",
"page": 86
},
{
"sheet": "A200",
"page": 87
},
{
"sheet": "A201",
"page": 88
},
{
"sheet": "A300",
"page": 89
},
{
"sheet": "S103",
"page": 95
},
{
"sheet": "S200",
"page": 96
},
{
"sheet": "S301",
"page": 98
}
],
"primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
"Meghan_concept_pages": [
3
],
"Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
"current_opening_units": [
"W110"
],
"adjoining_wall_inventory": [
"powder-boot-south",
"powder-boot",
"powder-north",
"entry-south",
"entry-porch-east"
],
"wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
"ceiling_controls": [
{
"id": "boot-room.main-ceiling",
"room": "boot-room",
"level": "main",
"plane_world_z_equals_ax_by_c": [
0,
0,
256.125
],
"quantity_type": "finished ceiling underside",
"basis": "A300centralR1finished-ceiling118.125in; Muskoka underside beam is separately108.5in above main.",
"source_class": "Primary source registered nominal plane",
"not_room_boundary": false,
"additional_regions": null
}
],
"later_changes_and_reconciliation": [
"Stone entry finish continues through muddy-boot removal area under owner direction. E5east envelope/outward side corrected; actual printed61in clear control passes. Cabinetry is custom proposed fit."
],
"model_census_by_state": {
"alcohol": {
"faces": 3512,
"object_records": 3
},
"espresso": {
"faces": 3512,
"object_records": 3
},
"espresso-open": {
"faces": 3512,
"object_records": 3
},
"alcohol-open": {
"faces": 3512,
"object_records": 3
},
"espresso-operating": {
"faces": 3512,
"object_records": 3
}
},
"source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
"transitions": {
"T1": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T2": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T3": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T4": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T5": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T6": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T7": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T8": {
"status": "held",
"reason": "Property transform/field levels unmeasured"
},
"T9": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
}
},
"whole_space_qualified": false,
"image_generation_allowed": false,
"owner_approval": null
}Main entry
Source/model qualification: HELD. No new image authorized.
Primary context: A102 p85, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).
- Intentional flush ceiling at proposedSB104underside113.39in above nominal main; structure/finish/services junction needs Nada/Alyssa.
- Fluted glass with amber/olive insert retained as appearance direction. Support, stability, attachment and entrance visibility remain design/engineering checks.
Room evidence JSON
{
"id": "entry",
"title": "Main entry",
"level": "main",
"source_aliases": [],
"primary_plan_context": [
{
"sheet": "A102",
"page": 85
},
{
"sheet": "A103",
"page": 86
},
{
"sheet": "A200",
"page": 87
},
{
"sheet": "A201",
"page": 88
},
{
"sheet": "A300",
"page": 89
},
{
"sheet": "S103",
"page": 95
},
{
"sheet": "S200",
"page": 96
},
{
"sheet": "S301",
"page": 98
}
],
"primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
"Meghan_concept_pages": [
3
],
"Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
"current_opening_units": [],
"adjoining_wall_inventory": [
"bed2-south-partition",
"hall-west",
"powder-boot",
"powder-north",
"entry-south",
"entry-porch-east",
"entry-porch-west"
],
"wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
"ceiling_controls": [
{
"id": "entry.main-ceiling",
"room": "entry",
"level": "main",
"plane_world_z_equals_ax_by_c": [
0,
0,
251.39
],
"quantity_type": "finished ceiling underside",
"basis": "Explicit proposed full/flush treatment at correctedSB104underside; owner intent plus131.5in steel top minus source18.11in profile. Services/lining/anchorage remain open.",
"source_class": "Explicit proposed coordination plane",
"not_room_boundary": false,
"additional_regions": null
}
],
"later_changes_and_reconciliation": [
"Intentional flush ceiling at proposedSB104underside113.39in above nominal main; structure/finish/services junction needs Nada/Alyssa.",
"Fluted glass with amber/olive insert retained as appearance direction. Support, stability, attachment and entrance visibility remain design/engineering checks."
],
"model_census_by_state": {
"alcohol": {
"faces": 99,
"object_records": 1
},
"espresso": {
"faces": 99,
"object_records": 1
},
"espresso-open": {
"faces": 99,
"object_records": 1
},
"alcohol-open": {
"faces": 99,
"object_records": 1
},
"espresso-operating": {
"faces": 99,
"object_records": 1
}
},
"source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
"transitions": {
"T1": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T2": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T3": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T4": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T5": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T6": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T7": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T8": {
"status": "held",
"reason": "Property transform/field levels unmeasured"
},
"T9": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
}
},
"whole_space_qualified": false,
"image_generation_allowed": false,
"owner_approval": null
}Kitchen
Source/model qualification: HELD. No new image authorized.
Primary context: A102 p85, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).
- Black tapware direction retained; source E1outward side corrected without shrinking pantry. Existing island/stool programme remains a design proposal, not a millwork shop drawing.
- Source-sized stools corrected. Appliance/counter-fridge selections and operating/service clearances remain open.
Room evidence JSON
{
"id": "kitchen",
"title": "Kitchen",
"level": "main",
"source_aliases": [],
"primary_plan_context": [
{
"sheet": "A102",
"page": 85
},
{
"sheet": "A103",
"page": 86
},
{
"sheet": "A200",
"page": 87
},
{
"sheet": "A201",
"page": 88
},
{
"sheet": "A300",
"page": 89
},
{
"sheet": "S103",
"page": 95
},
{
"sheet": "S200",
"page": 96
},
{
"sheet": "S301",
"page": 98
}
],
"primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
"Meghan_concept_pages": [
2
],
"Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
"current_opening_units": [
"W112"
],
"adjoining_wall_inventory": [
"entry-south",
"entry-porch-west",
"registered-west-E1",
"registered-kitchen-south-E1"
],
"wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
"ceiling_controls": [
{
"id": "kitchen.main-ceiling",
"room": "kitchen",
"level": "main",
"plane_world_z_equals_ax_by_c": [
0,
0,
251.39
],
"quantity_type": "finished ceiling underside",
"basis": "Explicit proposed full/flush treatment at correctedSB104underside; owner intent plus131.5in steel top minus source18.11in profile. Services/lining/anchorage remain open.",
"source_class": "Explicit proposed coordination plane",
"not_room_boundary": false,
"additional_regions": null
}
],
"later_changes_and_reconciliation": [
"Black tapware direction retained; source E1outward side corrected without shrinking pantry. Existing island/stool programme remains a design proposal, not a millwork shop drawing.",
"Source-sized stools corrected. Appliance/counter-fridge selections and operating/service clearances remain open."
],
"model_census_by_state": {
"alcohol": {
"faces": 2253,
"object_records": 518
},
"espresso": {
"faces": 2253,
"object_records": 518
},
"espresso-open": {
"faces": 2253,
"object_records": 518
},
"alcohol-open": {
"faces": 2253,
"object_records": 518
},
"espresso-operating": {
"faces": 2253,
"object_records": 518
}
},
"source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
"transitions": {
"T1": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T2": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T3": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T4": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T5": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T6": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T7": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T8": {
"status": "held",
"reason": "Property transform/field levels unmeasured"
},
"T9": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
}
},
"whole_space_qualified": false,
"image_generation_allowed": false,
"owner_approval": null
}Great room · living, dining & cozy nook
Source/model qualification: HELD. No new image authorized.
Primary context: A102 p85, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).
- Current full model has sloped R2living ceiling, corrected scheduled SB103/SB104,589mm horizontal curtain-bank gap and63.5mm vertical gap.
- Larger Swoon/floated loveseat preference retained. Real143x67cm Mikado table is parallel to sofa; owned matching JH501pair remain parked overflow.
- Alcohol is default. Five complete bar states retained; full conversion/loaded runners/electrical/steam/heat and cabinet support still require actual operation checks.
- Nook preferred small Oriel72x72/20in projection remains pending Nada; quote side/centre/depth reconciliation unresolved. OptionCis separate fallback. Rumford configuration unchanged.
- Bookcase colours/materials remain on hold in later November12record; do not promote earlier appearance to final material selection.
Room evidence JSON
{
"id": "greatroom",
"title": "Great room · living, dining & cozy nook",
"level": "main",
"source_aliases": [],
"primary_plan_context": [
{
"sheet": "A102",
"page": 85
},
{
"sheet": "A103",
"page": 86
},
{
"sheet": "A200",
"page": 87
},
{
"sheet": "A201",
"page": 88
},
{
"sheet": "A300",
"page": 89
},
{
"sheet": "S103",
"page": 95
},
{
"sheet": "S200",
"page": 96
},
{
"sheet": "S301",
"page": 98
}
],
"primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
"Meghan_concept_pages": [
4
],
"Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
"current_opening_units": [
"W109",
"TW106",
"TW107",
"TW105",
"TW104",
"TW103",
"CW-west-lower",
"CW-west-upper",
"CW-east-lower",
"CW-east-upper",
"W108"
],
"adjoining_wall_inventory": [
"hall-west",
"nook-south",
"nook-west",
"registered-west-E1",
"registered-lake-E1"
],
"wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
"ceiling_controls": [
{
"id": "greatroom.main-ceiling",
"room": "greatroom",
"level": "main",
"plane_world_z_equals_ax_by_c": [
-0.08333333333333333,
0,
346.206666666667
],
"quantity_type": "finished ceiling underside",
"basis": "A103/A300R2main living slope, independently reconciled148.5/176.125in finished-ceiling stations; source precision retained.",
"source_class": "Primary source registered nominal plane",
"not_room_boundary": true,
"additional_regions": "GreatRoomalso has centralR1approach/side ceilings; primary bath has lower wet enclosure. Read scoped controls, not a single-room height."
}
],
"later_changes_and_reconciliation": [
"Current full model has sloped R2living ceiling, corrected scheduled SB103/SB104,589mm horizontal curtain-bank gap and63.5mm vertical gap.",
"Larger Swoon/floated loveseat preference retained. Real143x67cm Mikado table is parallel to sofa; owned matching JH501pair remain parked overflow.",
"Alcohol is default. Five complete bar states retained; full conversion/loaded runners/electrical/steam/heat and cabinet support still require actual operation checks.",
"Nook preferred small Oriel72x72/20in projection remains pending Nada; quote side/centre/depth reconciliation unresolved. OptionCis separate fallback. Rumford configuration unchanged.",
"Bookcase colours/materials remain on hold in later November12record; do not promote earlier appearance to final material selection."
],
"model_census_by_state": {
"alcohol": {
"faces": 38927,
"object_records": 602
},
"espresso": {
"faces": 38915,
"object_records": 602
},
"espresso-open": {
"faces": 38932,
"object_records": 603
},
"alcohol-open": {
"faces": 38944,
"object_records": 603
},
"espresso-operating": {
"faces": 38915,
"object_records": 602
}
},
"source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
"transitions": {
"T1": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T2": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T3": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T4": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T5": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T6": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T7": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T8": {
"status": "held",
"reason": "Property transform/field levels unmeasured"
},
"T9": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
}
},
"whole_space_qualified": false,
"image_generation_allowed": false,
"owner_approval": null
}Three-season Muskoka room
Source/model qualification: HELD. No new image authorized.
Primary context: A102 p85, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).
- E101actual rough width131.75in, same main floor and north/lake fold direction. Exact head/sill/track/support and stack-jamb tolerance pending.
- E102single outswing pushed toward kitchen is a November11suggestion explicitly not ordered; preserve existing double/screen study.
Room evidence JSON
{
"id": "muskoka-room",
"title": "Three-season Muskoka room",
"level": "main",
"source_aliases": [],
"primary_plan_context": [
{
"sheet": "A102",
"page": 85
},
{
"sheet": "A103",
"page": 86
},
{
"sheet": "A200",
"page": 87
},
{
"sheet": "A201",
"page": 88
},
{
"sheet": "A300",
"page": 89
},
{
"sheet": "S103",
"page": 95
},
{
"sheet": "S200",
"page": 96
},
{
"sheet": "S301",
"page": 98
}
],
"primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
"Meghan_concept_pages": [],
"Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
"current_opening_units": [],
"adjoining_wall_inventory": [
"registered-west-E1"
],
"wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
"ceiling_controls": [
{
"id": "muskoka-room.main-ceiling",
"room": "muskoka-room",
"level": "main",
"plane_world_z_equals_ax_by_c": [
0,
0,
256.125
],
"quantity_type": "finished ceiling underside",
"basis": "A300centralR1finished-ceiling118.125in; Muskoka underside beam is separately108.5in above main.",
"source_class": "Primary source registered nominal plane",
"not_room_boundary": false,
"additional_regions": null
}
],
"later_changes_and_reconciliation": [
"E101actual rough width131.75in, same main floor and north/lake fold direction. Exact head/sill/track/support and stack-jamb tolerance pending.",
"E102single outswing pushed toward kitchen is a November11suggestion explicitly not ordered; preserve existing double/screen study."
],
"model_census_by_state": {
"alcohol": {
"faces": 1326,
"object_records": 8
},
"espresso": {
"faces": 1326,
"object_records": 8
},
"espresso-open": {
"faces": 1326,
"object_records": 8
},
"alcohol-open": {
"faces": 1326,
"object_records": 8
},
"espresso-operating": {
"faces": 1326,
"object_records": 8
}
},
"source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
"transitions": {
"T1": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T2": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T3": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T4": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T5": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T6": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T7": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T8": {
"status": "held",
"reason": "Property transform/field levels unmeasured"
},
"T9": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
}
},
"whole_space_qualified": false,
"image_generation_allowed": false,
"owner_approval": null
}Mechanical room
Source/model qualification: HELD. No new image authorized.
Primary context: A101 p84, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).
- A101113.375in substrate chain minus separate2in B1gives111.375in occupied clear; do not conflate quantities.
- 15in combined printed chain versus F2+B1nominal15.25in remains a source conflict. Mechanical systems/service clearances unselected.
Room evidence JSON
{
"id": "mechanical-room",
"title": "Mechanical room",
"level": "basement",
"source_aliases": [],
"primary_plan_context": [
{
"sheet": "A101",
"page": 84
},
{
"sheet": "A103",
"page": 86
},
{
"sheet": "A200",
"page": 87
},
{
"sheet": "A201",
"page": 88
},
{
"sheet": "A300",
"page": 89
},
{
"sheet": "S103",
"page": 95
},
{
"sheet": "S200",
"page": 96
},
{
"sheet": "S301",
"page": 98
}
],
"primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
"Meghan_concept_pages": [],
"Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
"current_opening_units": [],
"adjoining_wall_inventory": [
"foundation-east",
"foundation-south",
"foundation-mech-west",
"mech-bed4",
"mech-hall",
"bath-east",
"hall-bath-north",
"wing-east-B1-lining",
"mech-south-B1-lining"
],
"wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
"ceiling_controls": [
{
"id": "mechanical-room.main-ceiling",
"room": "mechanical-room",
"level": "basement",
"plane_world_z_equals_ax_by_c": [
0,
0,
108.0
],
"quantity_type": "finished ceiling underside",
"basis": "A300printed9ft finished basement ceiling; room uses that shared dropped-ceiling plane.",
"source_class": "Primary source registered nominal plane",
"not_room_boundary": false,
"additional_regions": null
}
],
"later_changes_and_reconciliation": [
"A101113.375in substrate chain minus separate2in B1gives111.375in occupied clear; do not conflate quantities.",
"15in combined printed chain versus F2+B1nominal15.25in remains a source conflict. Mechanical systems/service clearances unselected."
],
"model_census_by_state": {
"alcohol": {
"faces": 26,
"object_records": 1
},
"espresso": {
"faces": 26,
"object_records": 1
},
"espresso-open": {
"faces": 26,
"object_records": 1
},
"alcohol-open": {
"faces": 26,
"object_records": 1
},
"espresso-operating": {
"faces": 26,
"object_records": 1
}
},
"source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
"transitions": {
"T1": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T2": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T3": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T4": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T5": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T6": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T7": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T8": {
"status": "held",
"reason": "Property transform/field levels unmeasured"
},
"T9": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
}
},
"whole_space_qualified": false,
"image_generation_allowed": false,
"owner_approval": null
}Bedroom 4
Source/model qualification: HELD. No new image authorized.
Primary context: A101 p84, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).
- Source I2hall/alcove and4.5in bed/ensuite partition assignments reconciled. No newly ordered Harper window belongs here. Wardrobe is custom site-fit proposal.
Room evidence JSON
{
"id": "bedroom4",
"title": "Bedroom 4",
"level": "basement",
"source_aliases": [],
"primary_plan_context": [
{
"sheet": "A101",
"page": 84
},
{
"sheet": "A103",
"page": 86
},
{
"sheet": "A200",
"page": 87
},
{
"sheet": "A201",
"page": 88
},
{
"sheet": "A300",
"page": 89
},
{
"sheet": "S103",
"page": 95
},
{
"sheet": "S200",
"page": 96
},
{
"sheet": "S301",
"page": 98
}
],
"primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
"Meghan_concept_pages": [],
"Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
"current_opening_units": [
"W001"
],
"adjoining_wall_inventory": [
"foundation-east",
"mech-bed4",
"mech-hall",
"bed4-hall",
"bed4-alcove",
"bed4-storage",
"bed4-ensuite",
"wing-east-B1-lining"
],
"wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
"ceiling_controls": [
{
"id": "bedroom4.main-ceiling",
"room": "bedroom4",
"level": "basement",
"plane_world_z_equals_ax_by_c": [
0,
0,
108.0
],
"quantity_type": "finished ceiling underside",
"basis": "A300printed9ft finished basement ceiling; room uses that shared dropped-ceiling plane.",
"source_class": "Primary source registered nominal plane",
"not_room_boundary": false,
"additional_regions": null
}
],
"later_changes_and_reconciliation": [
"Source I2hall/alcove and4.5in bed/ensuite partition assignments reconciled. No newly ordered Harper window belongs here. Wardrobe is custom site-fit proposal."
],
"model_census_by_state": {
"alcohol": {
"faces": 1171,
"object_records": 9
},
"espresso": {
"faces": 1171,
"object_records": 9
},
"espresso-open": {
"faces": 1171,
"object_records": 9
},
"alcohol-open": {
"faces": 1171,
"object_records": 9
},
"espresso-operating": {
"faces": 1171,
"object_records": 9
}
},
"source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
"transitions": {
"T1": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T2": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T3": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T4": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T5": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T6": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T7": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T8": {
"status": "held",
"reason": "Property transform/field levels unmeasured"
},
"T9": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
}
},
"whole_space_qualified": false,
"image_generation_allowed": false,
"owner_approval": null
}Basement hall
Source/model qualification: HELD. No new image authorized.
Primary context: A101 p84, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).
- I2/I2.1source type arrows and adjoining bathroom/bedroom finish planes reconciled. Hall travel/door swing/threshold sweep still needs full operation acceptance.
Room evidence JSON
{
"id": "basement-hall",
"title": "Basement hall",
"level": "basement",
"source_aliases": [],
"primary_plan_context": [
{
"sheet": "A101",
"page": 84
},
{
"sheet": "A103",
"page": 86
},
{
"sheet": "A200",
"page": 87
},
{
"sheet": "A201",
"page": 88
},
{
"sheet": "A300",
"page": 89
},
{
"sheet": "S103",
"page": 95
},
{
"sheet": "S200",
"page": 96
},
{
"sheet": "S301",
"page": 98
}
],
"primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
"Meghan_concept_pages": [],
"Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
"current_opening_units": [],
"adjoining_wall_inventory": [
"mech-hall",
"hall-bath-north",
"bed4-hall",
"bed4-storage",
"wing-hall"
],
"wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
"ceiling_controls": [
{
"id": "basement-hall.main-ceiling",
"room": "basement-hall",
"level": "basement",
"plane_world_z_equals_ax_by_c": [
0,
0,
108.0
],
"quantity_type": "finished ceiling underside",
"basis": "A300printed9ft finished basement ceiling; room uses that shared dropped-ceiling plane.",
"source_class": "Primary source registered nominal plane",
"not_room_boundary": false,
"additional_regions": null
}
],
"later_changes_and_reconciliation": [
"I2/I2.1source type arrows and adjoining bathroom/bedroom finish planes reconciled. Hall travel/door swing/threshold sweep still needs full operation acceptance."
],
"model_census_by_state": {
"alcohol": {
"faces": 8,
"object_records": 1
},
"espresso": {
"faces": 8,
"object_records": 1
},
"espresso-open": {
"faces": 8,
"object_records": 1
},
"alcohol-open": {
"faces": 8,
"object_records": 1
},
"espresso-operating": {
"faces": 8,
"object_records": 1
}
},
"source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
"transitions": {
"T1": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T2": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T3": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T4": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T5": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T6": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T7": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T8": {
"status": "held",
"reason": "Property transform/field levels unmeasured"
},
"T9": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
}
},
"whole_space_qualified": false,
"image_generation_allowed": false,
"owner_approval": null
}Basement shared bathroom
Source/model qualification: HELD. No new image authorized.
Primary context: A101 p84, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).
- Missing bath/laundry return restored from A101actual paths. Net area62.892SFagrees with rounded63SFsecondary label.
- South B2particular assignment remains inferred. Tub/vanity moved rigidly to fit; final plumbing/fixture and wet installation not selected.
Room evidence JSON
{
"id": "basement-bathroom",
"title": "Basement shared bathroom",
"level": "basement",
"source_aliases": [],
"primary_plan_context": [
{
"sheet": "A101",
"page": 84
},
{
"sheet": "A103",
"page": 86
},
{
"sheet": "A200",
"page": 87
},
{
"sheet": "A201",
"page": 88
},
{
"sheet": "A300",
"page": 89
},
{
"sheet": "S103",
"page": 95
},
{
"sheet": "S200",
"page": 96
},
{
"sheet": "S301",
"page": 98
}
],
"primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
"Meghan_concept_pages": [
10
],
"Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
"current_opening_units": [],
"adjoining_wall_inventory": [
"foundation-bath-south",
"foundation-entry-east",
"bath-east",
"hall-bath-north",
"bath-south-finish-lining",
"bath-laundry-return"
],
"wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
"ceiling_controls": [
{
"id": "basement-bathroom.main-ceiling",
"room": "basement-bathroom",
"level": "basement",
"plane_world_z_equals_ax_by_c": [
0,
0,
108.0
],
"quantity_type": "finished ceiling underside",
"basis": "A300printed9ft finished basement ceiling; room uses that shared dropped-ceiling plane.",
"source_class": "Primary source registered nominal plane",
"not_room_boundary": false,
"additional_regions": null
}
],
"later_changes_and_reconciliation": [
"Missing bath/laundry return restored from A101actual paths. Net area62.892SFagrees with rounded63SFsecondary label.",
"South B2particular assignment remains inferred. Tub/vanity moved rigidly to fit; final plumbing/fixture and wet installation not selected."
],
"model_census_by_state": {
"alcohol": {
"faces": 802,
"object_records": 5
},
"espresso": {
"faces": 802,
"object_records": 5
},
"espresso-open": {
"faces": 802,
"object_records": 5
},
"alcohol-open": {
"faces": 802,
"object_records": 5
},
"espresso-operating": {
"faces": 802,
"object_records": 5
}
},
"source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
"transitions": {
"T1": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T2": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T3": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T4": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T5": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T6": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T7": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T8": {
"status": "held",
"reason": "Property transform/field levels unmeasured"
},
"T9": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
}
},
"whole_space_qualified": false,
"image_generation_allowed": false,
"owner_approval": null
}Bedroom 3 ensuite
Source/model qualification: HELD. No new image authorized.
Primary context: A101 p84, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).
- A10166in depth control passes;48x24in vanity rigidly moved beyond B1face. Custom shower/storage fitted to source finish bounds; exact products/plumbing/operation remain open.
Room evidence JSON
{
"id": "ensuite3",
"title": "Bedroom 3 ensuite",
"level": "basement",
"source_aliases": [],
"primary_plan_context": [
{
"sheet": "A101",
"page": 84
},
{
"sheet": "A103",
"page": 86
},
{
"sheet": "A200",
"page": 87
},
{
"sheet": "A201",
"page": 88
},
{
"sheet": "A300",
"page": 89
},
{
"sheet": "S103",
"page": 95
},
{
"sheet": "S200",
"page": 96
},
{
"sheet": "S301",
"page": 98
}
],
"primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
"Meghan_concept_pages": [],
"Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
"current_opening_units": [
"W002"
],
"adjoining_wall_inventory": [
"foundation-east",
"bed4-ensuite",
"ensuite-wic",
"ensuite-bedroom3",
"wing-east-B1-lining"
],
"wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
"ceiling_controls": [
{
"id": "ensuite3.main-ceiling",
"room": "ensuite3",
"level": "basement",
"plane_world_z_equals_ax_by_c": [
0,
0,
108.0
],
"quantity_type": "finished ceiling underside",
"basis": "A300printed9ft finished basement ceiling; room uses that shared dropped-ceiling plane.",
"source_class": "Primary source registered nominal plane",
"not_room_boundary": false,
"additional_regions": null
}
],
"later_changes_and_reconciliation": [
"A10166in depth control passes;48x24in vanity rigidly moved beyond B1face. Custom shower/storage fitted to source finish bounds; exact products/plumbing/operation remain open."
],
"model_census_by_state": {
"alcohol": {
"faces": 468,
"object_records": 11
},
"espresso": {
"faces": 468,
"object_records": 11
},
"espresso-open": {
"faces": 468,
"object_records": 11
},
"alcohol-open": {
"faces": 468,
"object_records": 11
},
"espresso-operating": {
"faces": 468,
"object_records": 11
}
},
"source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
"transitions": {
"T1": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T2": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T3": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T4": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T5": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T6": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T7": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T8": {
"status": "held",
"reason": "Property transform/field levels unmeasured"
},
"T9": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
}
},
"whole_space_qualified": false,
"image_generation_allowed": false,
"owner_approval": null
}Basement walk-in storage
Source/model qualification: HELD. No new image authorized.
Primary context: A101 p84, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).
- Primary partition envelope retained; custom shelves/wardrobes fitted to actual finish faces. Internal working/door/loaded storage dimensions remain proposals.
Room evidence JSON
{
"id": "basement-wic",
"title": "Basement walk-in storage",
"level": "basement",
"source_aliases": [],
"primary_plan_context": [
{
"sheet": "A101",
"page": 84
},
{
"sheet": "A103",
"page": 86
},
{
"sheet": "A200",
"page": 87
},
{
"sheet": "A201",
"page": 88
},
{
"sheet": "A300",
"page": 89
},
{
"sheet": "S103",
"page": 95
},
{
"sheet": "S200",
"page": 96
},
{
"sheet": "S301",
"page": 98
}
],
"primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
"Meghan_concept_pages": [],
"Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
"current_opening_units": [],
"adjoining_wall_inventory": [
"bed4-ensuite",
"ensuite-wic",
"ensuite-bedroom3",
"wing-hall"
],
"wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
"ceiling_controls": [
{
"id": "basement-wic.main-ceiling",
"room": "basement-wic",
"level": "basement",
"plane_world_z_equals_ax_by_c": [
0,
0,
108.0
],
"quantity_type": "finished ceiling underside",
"basis": "A300printed9ft finished basement ceiling; room uses that shared dropped-ceiling plane.",
"source_class": "Primary source registered nominal plane",
"not_room_boundary": false,
"additional_regions": null
}
],
"later_changes_and_reconciliation": [
"Primary partition envelope retained; custom shelves/wardrobes fitted to actual finish faces. Internal working/door/loaded storage dimensions remain proposals."
],
"model_census_by_state": {
"alcohol": {
"faces": 122,
"object_records": 1
},
"espresso": {
"faces": 122,
"object_records": 1
},
"espresso-open": {
"faces": 122,
"object_records": 1
},
"alcohol-open": {
"faces": 122,
"object_records": 1
},
"espresso-operating": {
"faces": 122,
"object_records": 1
}
},
"source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
"transitions": {
"T1": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T2": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T3": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T4": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T5": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T6": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T7": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T8": {
"status": "held",
"reason": "Property transform/field levels unmeasured"
},
"T9": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
}
},
"whole_space_qualified": false,
"image_generation_allowed": false,
"owner_approval": null
}Bedroom 3
Source/model qualification: HELD. No new image authorized.
Primary context: A101 p84, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).
- Harper additional woods-facing window: owner authorizes best-information location estimate; centred east wall with proposed matching W002family25x36in/sill48in. Not a tagged order or engineering approval.
- A101213.25in to substrate minus4in B2gives209.25in occupied width;123.25in depth. Approx179.1SFsecondary area agrees with179SFlabel.
Room evidence JSON
{
"id": "bedroom3",
"title": "Bedroom 3",
"level": "basement",
"source_aliases": [
"Harper bedroom"
],
"primary_plan_context": [
{
"sheet": "A101",
"page": 84
},
{
"sheet": "A103",
"page": 86
},
{
"sheet": "A200",
"page": 87
},
{
"sheet": "A201",
"page": 88
},
{
"sheet": "A300",
"page": 89
},
{
"sheet": "S103",
"page": 95
},
{
"sheet": "S200",
"page": 96
},
{
"sheet": "S301",
"page": 98
}
],
"primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
"Meghan_concept_pages": [],
"Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
"current_opening_units": [
"W003",
"EST-B3-WOODS-01"
],
"adjoining_wall_inventory": [
"foundation-east",
"bedroom3-north",
"walkout-north",
"walkout-east",
"ensuite-bedroom3",
"wing-hall",
"wing-east-B1-lining",
"bedroom3-east-B2-lining"
],
"wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
"ceiling_controls": [
{
"id": "bedroom3.main-ceiling",
"room": "bedroom3",
"level": "basement",
"plane_world_z_equals_ax_by_c": [
0,
0,
108.0
],
"quantity_type": "finished ceiling underside",
"basis": "A300printed9ft finished basement ceiling; room uses that shared dropped-ceiling plane.",
"source_class": "Primary source registered nominal plane",
"not_room_boundary": false,
"additional_regions": null
}
],
"later_changes_and_reconciliation": [
"Harper additional woods-facing window: owner authorizes best-information location estimate; centred east wall with proposed matching W002family25x36in/sill48in. Not a tagged order or engineering approval.",
"A101213.25in to substrate minus4in B2gives209.25in occupied width;123.25in depth. Approx179.1SFsecondary area agrees with179SFlabel."
],
"model_census_by_state": {
"alcohol": {
"faces": 1206,
"object_records": 3
},
"espresso": {
"faces": 1206,
"object_records": 3
},
"espresso-open": {
"faces": 1206,
"object_records": 3
},
"alcohol-open": {
"faces": 1206,
"object_records": 3
},
"espresso-operating": {
"faces": 1206,
"object_records": 3
}
},
"source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
"transitions": {
"T1": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T2": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T3": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T4": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T5": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T6": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T7": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T8": {
"status": "held",
"reason": "Property transform/field levels unmeasured"
},
"T9": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
}
},
"whole_space_qualified": false,
"image_generation_allowed": false,
"owner_approval": null
}Lower entry & stair arrival
Source/model qualification: HELD. No new image authorized.
Primary context: A101 p84, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).
- W007owner alias lower-entry-side window is physically the RecRoom recess casement; no extra RecRoomwindow is invented.
- Basement108in ceiling restored over lower stair region per A102opening. Exact threshold/floor build-up and property-grade transform remain open.
Room evidence JSON
{
"id": "lower-entry",
"title": "Lower entry & stair arrival",
"level": "basement",
"source_aliases": [],
"primary_plan_context": [
{
"sheet": "A101",
"page": 84
},
{
"sheet": "A103",
"page": 86
},
{
"sheet": "A200",
"page": 87
},
{
"sheet": "A201",
"page": 88
},
{
"sheet": "A300",
"page": 89
},
{
"sheet": "S103",
"page": 95
},
{
"sheet": "S200",
"page": 96
},
{
"sheet": "S301",
"page": 98
}
],
"primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
"Meghan_concept_pages": [],
"Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
"current_opening_units": [
"E002"
],
"adjoining_wall_inventory": [
"walkout-north",
"hall-bath-north",
"wing-hall",
"hall-laundry",
"rec-hall"
],
"wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
"ceiling_controls": [
{
"id": "lower-entry.main-ceiling",
"room": "lower-entry",
"level": "basement",
"plane_world_z_equals_ax_by_c": [
0,
0,
108.0
],
"quantity_type": "finished ceiling underside",
"basis": "A300printed9ft finished basement ceiling; room uses that shared dropped-ceiling plane.",
"source_class": "Primary source registered nominal plane",
"not_room_boundary": false,
"additional_regions": null
}
],
"later_changes_and_reconciliation": [
"W007owner alias lower-entry-side window is physically the RecRoom recess casement; no extra RecRoomwindow is invented.",
"Basement108in ceiling restored over lower stair region per A102opening. Exact threshold/floor build-up and property-grade transform remain open."
],
"model_census_by_state": {
"alcohol": {
"faces": 57,
"object_records": 1
},
"espresso": {
"faces": 57,
"object_records": 1
},
"espresso-open": {
"faces": 57,
"object_records": 1
},
"alcohol-open": {
"faces": 57,
"object_records": 1
},
"espresso-operating": {
"faces": 57,
"object_records": 1
}
},
"source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
"transitions": {
"T1": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T2": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T3": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T4": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T5": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T6": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T7": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T8": {
"status": "held",
"reason": "Property transform/field levels unmeasured"
},
"T9": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
}
},
"whole_space_qualified": false,
"image_generation_allowed": false,
"owner_approval": null
}Basement laundry
Source/model qualification: HELD. No new image authorized.
Primary context: A101 p84, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).
- Actual source bathroom return and north I1partition reconciled; machines moved rigidly0.2in; custom counter/hanging storage fitted. Appliance/service/door operation remains unselected.
Room evidence JSON
{
"id": "basement-laundry",
"title": "Basement laundry",
"level": "basement",
"source_aliases": [],
"primary_plan_context": [
{
"sheet": "A101",
"page": 84
},
{
"sheet": "A103",
"page": 86
},
{
"sheet": "A200",
"page": 87
},
{
"sheet": "A201",
"page": 88
},
{
"sheet": "A300",
"page": 89
},
{
"sheet": "S103",
"page": 95
},
{
"sheet": "S200",
"page": 96
},
{
"sheet": "S301",
"page": 98
}
],
"primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
"Meghan_concept_pages": [
11
],
"Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
"current_opening_units": [],
"adjoining_wall_inventory": [
"foundation-entry-north",
"hall-bath-north",
"hall-laundry",
"laundry-north",
"laundry-media",
"bath-laundry-return"
],
"wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
"ceiling_controls": [
{
"id": "basement-laundry.main-ceiling",
"room": "basement-laundry",
"level": "basement",
"plane_world_z_equals_ax_by_c": [
0,
0,
108.0
],
"quantity_type": "finished ceiling underside",
"basis": "A300printed9ft finished basement ceiling; room uses that shared dropped-ceiling plane.",
"source_class": "Primary source registered nominal plane",
"not_room_boundary": false,
"additional_regions": null
}
],
"later_changes_and_reconciliation": [
"Actual source bathroom return and north I1partition reconciled; machines moved rigidly0.2in; custom counter/hanging storage fitted. Appliance/service/door operation remains unselected."
],
"model_census_by_state": {
"alcohol": {
"faces": 538,
"object_records": 27
},
"espresso": {
"faces": 538,
"object_records": 27
},
"espresso-open": {
"faces": 538,
"object_records": 27
},
"alcohol-open": {
"faces": 538,
"object_records": 27
},
"espresso-operating": {
"faces": 538,
"object_records": 27
}
},
"source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
"transitions": {
"T1": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T2": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T3": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T4": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T5": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T6": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T7": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T8": {
"status": "held",
"reason": "Property transform/field levels unmeasured"
},
"T9": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
}
},
"whole_space_qualified": false,
"image_generation_allowed": false,
"owner_approval": null
}Golf simulator & media room
Source/model qualification: HELD. No new image authorized.
Primary context: A101 p84, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).
- A101NO DROPPED CEILING: current125in finish study is125.5in framing less inferred0.5in lining. Services/finish thickness open.
- 189.125in width and122.625in substrate depth minus2in B1=120.625in occupied depth. Golf simulator/swing/equipment specifications still need actual-size operational study.
Room evidence JSON
{
"id": "media-room",
"title": "Golf simulator & media room",
"level": "basement",
"source_aliases": [],
"primary_plan_context": [
{
"sheet": "A101",
"page": 84
},
{
"sheet": "A103",
"page": 86
},
{
"sheet": "A200",
"page": 87
},
{
"sheet": "A201",
"page": 88
},
{
"sheet": "A300",
"page": 89
},
{
"sheet": "S103",
"page": 95
},
{
"sheet": "S200",
"page": 96
},
{
"sheet": "S301",
"page": 98
}
],
"primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
"Meghan_concept_pages": [],
"Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
"current_opening_units": [],
"adjoining_wall_inventory": [
"foundation-entry-west",
"foundation-media-south",
"foundation-west",
"laundry-media",
"media-rec",
"media-B1-lining",
"media-south-B1-lining"
],
"wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
"ceiling_controls": [
{
"id": "media-room.main-ceiling",
"room": "media-room",
"level": "basement",
"plane_world_z_equals_ax_by_c": [
0,
0,
125.0
],
"quantity_type": "finished ceiling underside",
"basis": "A101no dropped ceiling; A300125.5in framing less explicitly inferred0.5in finish.",
"source_class": "Explicit proposed coordination plane",
"not_room_boundary": false,
"additional_regions": null
}
],
"later_changes_and_reconciliation": [
"A101NO DROPPED CEILING: current125in finish study is125.5in framing less inferred0.5in lining. Services/finish thickness open.",
"189.125in width and122.625in substrate depth minus2in B1=120.625in occupied depth. Golf simulator/swing/equipment specifications still need actual-size operational study."
],
"model_census_by_state": {
"alcohol": {
"faces": 62,
"object_records": 1
},
"espresso": {
"faces": 62,
"object_records": 1
},
"espresso-open": {
"faces": 62,
"object_records": 1
},
"alcohol-open": {
"faces": 62,
"object_records": 1
},
"espresso-operating": {
"faces": 62,
"object_records": 1
}
},
"source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
"transitions": {
"T1": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T2": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T3": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T4": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T5": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T6": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T7": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T8": {
"status": "held",
"reason": "Property transform/field levels unmeasured"
},
"T9": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
}
},
"whole_space_qualified": false,
"image_generation_allowed": false,
"owner_approval": null
}Rec room, lounge & stowaway guest bunks
Source/model qualification: HELD. No new image authorized.
Primary context: A101 p84, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).
- 333.375in occupied width is335.375in printed substrate span minus2in B1. Depth222.125in retained; approx514.3SFagrees with rounded514SFsecondary label.
- W007baseline24x72in added in November11programme; updated order/profile not supplied. Interior rec-hall wrongly continued across it; corrected to stop at source walkout-north closure.
- Stowaway bunks/guest/TV fixtures remain design proposals requiring actual products, loaded/occupied operation and final clearances.
Room evidence JSON
{
"id": "rec-room",
"title": "Rec room, lounge & stowaway guest bunks",
"level": "basement",
"source_aliases": [],
"primary_plan_context": [
{
"sheet": "A101",
"page": 84
},
{
"sheet": "A103",
"page": 86
},
{
"sheet": "A200",
"page": 87
},
{
"sheet": "A201",
"page": 88
},
{
"sheet": "A300",
"page": 89
},
{
"sheet": "S103",
"page": 95
},
{
"sheet": "S200",
"page": 96
},
{
"sheet": "S301",
"page": 98
}
],
"primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
"Meghan_concept_pages": [],
"Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
"current_opening_units": [
"W004",
"W005",
"W006",
"E004",
"W007"
],
"adjoining_wall_inventory": [
"foundation-west",
"rec-north",
"walkout-north",
"walkout-west",
"hall-laundry",
"laundry-north",
"media-rec",
"rec-hall",
"rec-B1-lining"
],
"wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
"ceiling_controls": [
{
"id": "rec-room.main-ceiling",
"room": "rec-room",
"level": "basement",
"plane_world_z_equals_ax_by_c": [
0,
0,
108.0
],
"quantity_type": "finished ceiling underside",
"basis": "A300printed9ft finished basement ceiling; room uses that shared dropped-ceiling plane.",
"source_class": "Primary source registered nominal plane",
"not_room_boundary": false,
"additional_regions": null
}
],
"later_changes_and_reconciliation": [
"333.375in occupied width is335.375in printed substrate span minus2in B1. Depth222.125in retained; approx514.3SFagrees with rounded514SFsecondary label.",
"W007baseline24x72in added in November11programme; updated order/profile not supplied. Interior rec-hall wrongly continued across it; corrected to stop at source walkout-north closure.",
"Stowaway bunks/guest/TV fixtures remain design proposals requiring actual products, loaded/occupied operation and final clearances."
],
"model_census_by_state": {
"alcohol": {
"faces": 1382,
"object_records": 7
},
"espresso": {
"faces": 1382,
"object_records": 7
},
"espresso-open": {
"faces": 1382,
"object_records": 7
},
"alcohol-open": {
"faces": 1382,
"object_records": 7
},
"espresso-operating": {
"faces": 1382,
"object_records": 7
}
},
"source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
"transitions": {
"T1": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T2": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T3": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T4": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T5": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T6": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T7": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T8": {
"status": "held",
"reason": "Property transform/field levels unmeasured"
},
"T9": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
}
},
"whole_space_qualified": false,
"image_generation_allowed": false,
"owner_approval": null
}Interior stairs & landings
Source/model qualification: HELD. No new image authorized.
Primary context: A101 p84, A102 p85, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).
- 18actual upper tread surfaces;18th is main-floor landing.138/18in nominal riser;10in going;46.48in tread width.
- 270nosing-adjacent/midgoing width probes give minimum77.33333in model clearance. Source1950mmcontrol remains separate; continuous sweep/rails/landing/channel/installation and code certification not established.
Room evidence JSON
{
"id": "stairs",
"title": "Interior stairs & landings",
"level": "both",
"source_aliases": [],
"primary_plan_context": [
{
"sheet": "A101",
"page": 84
},
{
"sheet": "A102",
"page": 85
},
{
"sheet": "A103",
"page": 86
},
{
"sheet": "A200",
"page": 87
},
{
"sheet": "A201",
"page": 88
},
{
"sheet": "A300",
"page": 89
},
{
"sheet": "S103",
"page": 95
},
{
"sheet": "S200",
"page": 96
},
{
"sheet": "S301",
"page": 98
}
],
"primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
"Meghan_concept_pages": [
9
],
"Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
"current_opening_units": [],
"adjoining_wall_inventory": [],
"wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
"ceiling_controls": [],
"later_changes_and_reconciliation": [
"18actual upper tread surfaces;18th is main-floor landing.138/18in nominal riser;10in going;46.48in tread width.",
"270nosing-adjacent/midgoing width probes give minimum77.33333in model clearance. Source1950mmcontrol remains separate; continuous sweep/rails/landing/channel/installation and code certification not established."
],
"model_census_by_state": {
"alcohol": {
"faces": 1008,
"object_records": 0
},
"espresso": {
"faces": 1008,
"object_records": 0
},
"espresso-open": {
"faces": 1008,
"object_records": 0
},
"alcohol-open": {
"faces": 1008,
"object_records": 0
},
"espresso-operating": {
"faces": 1008,
"object_records": 0
}
},
"source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
"transitions": {
"T1": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T2": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T3": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T4": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T5": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T6": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T7": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T8": {
"status": "held",
"reason": "Property transform/field levels unmeasured"
},
"T9": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
}
},
"whole_space_qualified": false,
"image_generation_allowed": false,
"owner_approval": null
}Decks, porches & exterior thresholds
Source/model qualification: HELD. No new image authorized.
Primary context: A102 p85, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).
- Interior coordinate origin is not surveyed property registration. Source thresholds/roof/guards/footprints remain separate from terrain/root/permission evidence.
- Property Studio remains the GEEKOMsingle writer; current curated exterior package is the November13Synology export. No geometry/state copied back or changed.
Room evidence JSON
{
"id": "decks-porches",
"title": "Decks, porches & exterior thresholds",
"level": "exterior",
"source_aliases": [],
"primary_plan_context": [
{
"sheet": "A102",
"page": 85
},
{
"sheet": "A103",
"page": 86
},
{
"sheet": "A200",
"page": 87
},
{
"sheet": "A201",
"page": 88
},
{
"sheet": "A300",
"page": 89
},
{
"sheet": "S103",
"page": 95
},
{
"sheet": "S200",
"page": 96
},
{
"sheet": "S301",
"page": 98
}
],
"primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
"Meghan_concept_pages": [],
"Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
"current_opening_units": [],
"adjoining_wall_inventory": [],
"wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
"ceiling_controls": [],
"later_changes_and_reconciliation": [
"Interior coordinate origin is not surveyed property registration. Source thresholds/roof/guards/footprints remain separate from terrain/root/permission evidence.",
"Property Studio remains the GEEKOMsingle writer; current curated exterior package is the November13Synology export. No geometry/state copied back or changed."
],
"model_census_by_state": {
"alcohol": {
"faces": 3615,
"object_records": 6
},
"espresso": {
"faces": 3615,
"object_records": 6
},
"espresso-open": {
"faces": 3615,
"object_records": 6
},
"alcohol-open": {
"faces": 3615,
"object_records": 6
},
"espresso-operating": {
"faces": 3615,
"object_records": 6
}
},
"source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
"transitions": {
"T1": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T2": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T3": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T4": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T5": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T6": {
"status": "not run / upstream measurement hold",
"reason": "No new native render/design image authorized before model validation"
},
"T7": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
},
"T8": {
"status": "held",
"reason": "Property transform/field levels unmeasured"
},
"T9": {
"status": "held",
"reason": "Complete room source/quantity/operation and current release acceptance required"
}
},
"whole_space_qualified": false,
"image_generation_allowed": false,
"owner_approval": null
}Coordination questions · drafts only, nothing sent
DRAFT ONLY — nothing sent; no owner or engineering approval. Current source findings supersede historical open-question wording. 1. Nada / Alyssa / Meghan — common roof, timber, steel and finish section Scheduled SB103 top 158.5 in andSB104 top 131.5 in are restored. Coordinate rolled profiles, C103 plates/cut, full-width nailer thickness, timber bearing/exposure, services, finish-floor build-up and the intentional fully flush/below kitchen-entry ceiling. Current flush study is 113.39 in above nominal main; it is not an engineered detail. 2. Nada / supplier / Alyssa — current Oriel shop box and support Oriel remains preferred pending viability. Reconcile 72 x 72 in programme,20 in email projection plus 5.5 in jamb, SIDE31.5/CENTER63 quote modules, actual frame/trim envelope, support, operable returns and adjacentW108. Current exact profile is inferred. Option Cis an independent fallback; do not change the Rumford without a separate decision. 3. Alyssa / Matt / Nada — revised tagged window/order and installation section The marked sketch resolves 589 mm horizontal bank gap and 63.5 mm vertical frame separation; those questions are not still unknown. Need current tagged shop/set-out/RSO/sill/head/frame-glass profiles, separator/support/shear-stud detail, W007 addition and proposed Harper window. Retain two 60 x 28.875 in TW106/TW107 units; extra 60 x 30 line was removed. E101 width 131.75 in is explicit, retained 96.5 in head is not final. E00444 in ICF/39 in framed/38 in frame widths are distinct; blockout height/bucks/anchorage remain open. 4. Nada / Meghan / Alyssa — primary bathroom finish registration and basement lining chain Later I104149.5 x 138 in room ends 0.12 in inside the earlier south partition face when its north finish is registered. Confirm final finish/backing or source adjustment without rescaling fixtures. Separately resolve mechanical 15 in printed composite versus 13.25 in F2 plus 2 in B1=15.25 in; preserve each layer and its source. 5. Meghan / millworker / installers — actual product and occupied operation checks Finish full-size cabinet/door/runner/lever/user sweeps and loaded supports for five espresso/alcohol states, all three large trays,15 juleps/two buckets and collector book; maintain beautiful closed coffee cover. Final appliances/plumbing, gas stove/fire clearances, bunk deployment, simulator swing, stairs/guard/channel and glass partition attachment remain to coordinate. Do not replace nominal envelopes with fabricated fit. 6. Project team — property/common datum Use the current November 13 curated exterior brief and GEEKOMworking source. Establish a common building/property transform and measured thresholds/ground/root/landing levels. Historical designed route profiles and internal numeric fits do not establish surveyed ground, permissions or construction-ready access.
Current release status JSON
{
"status": "measurement gate held",
"model_revision": "v18",
"models": [
{
"id": "alcohol",
"title": "Current working correction · alcohol · measurement hold",
"file": "room_review/decisions/room-reconciliation-20261115-r26-v18/model-alcohol.027b37142079ffdc363c.json",
"sha256": "027b37142079ffdc363cba8cbc0ddc4c63005ed2eb46f80030a8f76d2ee8f373",
"viewer": "room_review/decisions/room-reconciliation-20261115-r26-v18/3d-alcohol.html",
"rooms": 23,
"floors": [
"main",
"basement"
],
"scope": "Full v18 candidate; larger upholstered chair/floated loveseat and default alcohol bar retained. Complete source/detail/operations gate held; no new images."
},
{
"id": "espresso",
"title": "Current working correction · espresso · measurement hold",
"file": "room_review/decisions/room-reconciliation-20261115-r26-v18/model-espresso.dc6653684f05404ad111.json",
"sha256": "dc6653684f05404ad1113e1f42a7a59a5fb46275aa476a141c77147cce86f533",
"viewer": "room_review/decisions/room-reconciliation-20261115-r26-v18/3d-espresso.html",
"rooms": 23,
"floors": [
"main",
"basement"
],
"scope": "Full v18 candidate; larger upholstered chair/floated loveseat and default alcohol bar retained. Complete source/detail/operations gate held; no new images."
},
{
"id": "espresso-open",
"title": "Current working correction · espresso-open · measurement hold",
"file": "room_review/decisions/room-reconciliation-20261115-r26-v18/model-espresso-open.1f5b9922e9211298f11e.json",
"sha256": "1f5b9922e9211298f11e10e98cbef5798ca48292a143497ea00abf746c03ed20",
"viewer": "room_review/decisions/room-reconciliation-20261115-r26-v18/3d-espresso-open.html",
"rooms": 23,
"floors": [
"main",
"basement"
],
"scope": "Full v18 candidate; larger upholstered chair/floated loveseat and default alcohol bar retained. Complete source/detail/operations gate held; no new images."
},
{
"id": "alcohol-open",
"title": "Current working correction · alcohol-open · measurement hold",
"file": "room_review/decisions/room-reconciliation-20261115-r26-v18/model-alcohol-open.508342117f4cba7b8262.json",
"sha256": "508342117f4cba7b8262a8ef4f5179bdd69d4e961b09a0f39f3b1600b19b4a16",
"viewer": "room_review/decisions/room-reconciliation-20261115-r26-v18/3d-alcohol-open.html",
"rooms": 23,
"floors": [
"main",
"basement"
],
"scope": "Full v18 candidate; larger upholstered chair/floated loveseat and default alcohol bar retained. Complete source/detail/operations gate held; no new images."
},
{
"id": "espresso-operating",
"title": "Current working correction · espresso-operating · measurement hold",
"file": "room_review/decisions/room-reconciliation-20261115-r26-v18/model-espresso-operating.d920df685aad1a33557f.json",
"sha256": "d920df685aad1a33557f45e62683c2b5bda9f83d1bd287d92683e86f6944a207",
"viewer": "room_review/decisions/room-reconciliation-20261115-r26-v18/3d-espresso-operating.html",
"rooms": 23,
"floors": [
"main",
"basement"
],
"scope": "Full v18 candidate; larger upholstered chair/floated loveseat and default alcohol bar retained. Complete source/detail/operations gate held; no new images."
}
],
"rooms": 23,
"states": 5,
"new_design_images": 0,
"checks_per_state": {
"nominal_frame_envelopes_pass": 35,
"actual_glazing_apertures_pass": 38,
"product_instances_pass": 14,
"typed_room_chains_pass": 11,
"reported_defect_critical_controls_pass": 41
},
"sampling": {
"frames": 460,
"controls": 494,
"scope": "23room scopes x5states xT1/T2/T3/T9; all held. Incomplete inventories/required unknowns prevent whole-room claims. Original W104source false failure and same-draw corrected observer receipts preserved."
},
"actual_remaining_boundary_failure": [
{
"id": "main.bed1-south-partition.normal-min",
"wall": "bed1-south-partition",
"level": "main",
"quantity": "normal-min",
"expected_inches": 332.46999999999997,
"observed_inches": 332.35,
"delta_inches": -0.1199999999999477,
"status": "fail",
"tolerance_inches": 0.0625,
"tolerance_basis": "Nominal programme/source stroke and retained0.035in cosmetic skin; not field or construction tolerance.",
"probe": {
"axis": 1,
"along_inches": 47.39999999999999,
"height_inches": 145,
"selection_rule": "Predeclared fraction/height order excluding source-defined openings and buried closed-junction faces, solely from the2Dprogramme; no observation-dependent swap.",
"source_exclusions": [
{
"along_inches": 28.659999999999986,
"reason": "The nominal finish probe is buried inside a different source-defined wall at a closed junction; this is not an exposed face.",
"source_intersecting_walls": [
"bed-east"
]
}
]
},
"actual_planes_inches": [
332.35,
332.47,
338.97
],
"actual_face_ids_by_plane": {
"332.47": [
"house-face-367"
],
"338.97": [
"house-face-369"
],
"332.35": [
"bathroom-r28::nov03-2"
]
},
"source_basis": "Typed full finished-assembly envelope from source-plan-v2; original core trace retained separately. Source-class/assignment and whole-space QA remain held."
},
{
"id": "main.bed1-south-partition.nominal-envelope-thickness",
"wall": "bed1-south-partition",
"level": "main",
"quantity": "nominal-envelope-thickness",
"expected_inches": 6.5,
"observed_inches": 6.6200000000000045,
"delta_inches": 0.12000000000000455,
"status": "fail",
"tolerance_inches": 0.0625,
"tolerance_basis": "Nominal programme/source stroke and retained0.035in cosmetic skin; not field or construction tolerance.",
"probe": {
"axis": 1,
"along_inches": 47.39999999999999,
"height_inches": 145,
"selection_rule": "Predeclared fraction/height order excluding source-defined openings and buried closed-junction faces, solely from the2Dprogramme; no observation-dependent swap.",
"source_exclusions": [
{
"along_inches": 28.659999999999986,
"reason": "The nominal finish probe is buried inside a different source-defined wall at a closed junction; this is not an exposed face.",
"source_intersecting_walls": [
"bed-east"
]
}
]
},
"actual_planes_inches": [
332.35,
332.47,
338.97
],
"actual_face_ids_by_plane": {
"332.47": [
"house-face-367"
],
"338.97": [
"house-face-369"
],
"332.35": [
"bathroom-r28::nov03-2"
]
},
"source_basis": "Typed full finished-assembly envelope from source-plan-v2; original core trace retained separately. Source-class/assignment and whole-space QA remain held."
}
],
"remaining_draft_questions": "draft-questions.txt",
"source_profile_and_operations_qualified": false,
"owner_approval": null
}Full room register · Actual wall/frame observations · Aperture/contact/stair checks · Actual product envelopes and furniture gaps · Typed room chains · Critical controls and rejection fixtures · All original sampling dispositions · Corrected W104 source observer · Current canonical plan JSON
Property context: Current curated exterior team package. GEEKOM remains the authoritative working writer. No surveyed common datum, terrain, root or permission qualification is implied.