November 15, 2026 · R25–R29 working issue

Measured design review and current full 3D

The whole-model measurement gate is HELD.

Current corrections are available for review. No new design image/native render, owner approval or construction authorization was created. The bathroom boundary discrepancy, source/detail and operation gaps remain open. Oriel is preferred pending Nada; Option C is a separate fallback. The larger upholstered chair/floated loveseat and default alcohol bar remain the starting preference.

Download the 26-page draft measurement book · Download frozen sampling, observations and reproducible observers · Draft coordination questions

alcoholFull house · both floors · measurement holdespressoFull house · both floors · measurement holdespresso-openFull house · both floors · measurement holdalcohol-openFull house · both floors · measurement holdespresso-operatingFull house · both floors · measurement hold

Actual geometry checked

In every state: 35 tagged frame envelopes, 38 glazing/view apertures, 14 furniture instances and 11 typed room chains pass their declared checks. Forty-one reported-defect/steel/chair/CW controls pass; five controls in that observer remain unverifiable. All five building shells are identical. These scoped results do not establish whole-space source or operation qualification.

460 frozen T1/T2/T3/T9 diagnostics cover 23 room scopes in five states. All remain held. The original W104 source-observer failure and corrected same-draw receipts are both retained. No statistical whole-house claim is made. Image stages T4–T6 remain unrun; browser/export T7 and property-registration T8 need separate evidence.

Go through each area

Bedroom 1 · Chris

Source/model qualification: HELD. No new image authorized.

Primary context: A102 p85, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).

Room evidence JSON
{
  "id": "bedroom1",
  "title": "Bedroom 1 · Chris",
  "level": "main",
  "source_aliases": [
    "Chris bedroom",
    "Meghan concept Bedroom2"
  ],
  "primary_plan_context": [
    {
      "sheet": "A102",
      "page": 85
    },
    {
      "sheet": "A103",
      "page": 86
    },
    {
      "sheet": "A200",
      "page": 87
    },
    {
      "sheet": "A201",
      "page": 88
    },
    {
      "sheet": "A300",
      "page": 89
    },
    {
      "sheet": "S103",
      "page": 95
    },
    {
      "sheet": "S200",
      "page": 96
    },
    {
      "sheet": "S301",
      "page": 98
    }
  ],
  "primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
  "Meghan_concept_pages": [
    8
  ],
  "Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
  "current_opening_units": [
    "W105",
    "W106",
    "E100",
    "TW100",
    "TW101",
    "TW102"
  ],
  "adjoining_wall_inventory": [
    "bed-east",
    "bed1-south-partition",
    "bed-north",
    "hall-west",
    "nook-south"
  ],
  "wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
  "ceiling_controls": [
    {
      "id": "bedroom1.main-ceiling",
      "room": "bedroom1",
      "level": "main",
      "plane_world_z_equals_ax_by_c": [
        0.08333333333333333,
        0,
        267.511666666667
      ],
      "quantity_type": "finished ceiling underside",
      "basis": "Shared source-registered A103/A300bedroom-wing R2slope; independent132.125/151.375in source stations and1:12pitch.",
      "source_class": "Primary source registered nominal plane",
      "not_room_boundary": false,
      "additional_regions": null
    }
  ],
  "later_changes_and_reconciliation": [
    "Architectural Bedroom1 is Chris; Meghan concept Bedroom2. Manufacturer/fixture positions are design studies; bedroom gas decision remains open."
  ],
  "model_census_by_state": {
    "alcohol": {
      "faces": 2088,
      "object_records": 16
    },
    "espresso": {
      "faces": 2088,
      "object_records": 16
    },
    "espresso-open": {
      "faces": 2088,
      "object_records": 16
    },
    "alcohol-open": {
      "faces": 2088,
      "object_records": 16
    },
    "espresso-operating": {
      "faces": 2088,
      "object_records": 16
    }
  },
  "source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
  "transitions": {
    "T1": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T2": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T3": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T4": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T5": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T6": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T7": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T8": {
      "status": "held",
      "reason": "Property transform/field levels unmeasured"
    },
    "T9": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    }
  },
  "whole_space_qualified": false,
  "image_generation_allowed": false,
  "owner_approval": null
}

Bedroom 2 · Michelle

Source/model qualification: HELD. No new image authorized.

Primary context: A102 p85, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).

Room evidence JSON
{
  "id": "bedroom2",
  "title": "Bedroom 2 · Michelle",
  "level": "main",
  "source_aliases": [
    "Michelle bedroom",
    "Meghan concept Bedroom1"
  ],
  "primary_plan_context": [
    {
      "sheet": "A102",
      "page": 85
    },
    {
      "sheet": "A103",
      "page": 86
    },
    {
      "sheet": "A200",
      "page": 87
    },
    {
      "sheet": "A201",
      "page": 88
    },
    {
      "sheet": "A300",
      "page": 89
    },
    {
      "sheet": "S103",
      "page": 95
    },
    {
      "sheet": "S200",
      "page": 96
    },
    {
      "sheet": "S301",
      "page": 98
    }
  ],
  "primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
  "Meghan_concept_pages": [
    7
  ],
  "Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
  "current_opening_units": [
    "W100",
    "W101",
    "W102"
  ],
  "adjoining_wall_inventory": [
    "bed-east",
    "bed-south",
    "bed2-west",
    "bed2-south-partition",
    "hall-west",
    "powder-boot-south"
  ],
  "wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
  "ceiling_controls": [
    {
      "id": "bedroom2.main-ceiling",
      "room": "bedroom2",
      "level": "main",
      "plane_world_z_equals_ax_by_c": [
        0.08333333333333333,
        0,
        267.511666666667
      ],
      "quantity_type": "finished ceiling underside",
      "basis": "Shared source-registered A103/A300bedroom-wing R2slope; independent132.125/151.375in source stations and1:12pitch.",
      "source_class": "Primary source registered nominal plane",
      "not_room_boundary": false,
      "additional_regions": null
    }
  ],
  "later_changes_and_reconciliation": [
    "Architectural Bedroom2 is Michelle; Meghan concept Bedroom1. Current nominal finished219.875x156in replaces the oversized old core-only room."
  ],
  "model_census_by_state": {
    "alcohol": {
      "faces": 1518,
      "object_records": 13
    },
    "espresso": {
      "faces": 1518,
      "object_records": 13
    },
    "espresso-open": {
      "faces": 1518,
      "object_records": 13
    },
    "alcohol-open": {
      "faces": 1518,
      "object_records": 13
    },
    "espresso-operating": {
      "faces": 1518,
      "object_records": 13
    }
  },
  "source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
  "transitions": {
    "T1": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T2": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T3": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T4": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T5": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T6": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T7": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T8": {
      "status": "held",
      "reason": "Property transform/field levels unmeasured"
    },
    "T9": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    }
  },
  "whole_space_qualified": false,
  "image_generation_allowed": false,
  "owner_approval": null
}

Primary bathroom

Source/model qualification: HELD. No new image authorized.

Primary context: A102 p85, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).

Room evidence JSON
{
  "id": "primary-bathroom",
  "title": "Primary bathroom",
  "level": "main",
  "source_aliases": [],
  "primary_plan_context": [
    {
      "sheet": "A102",
      "page": 85
    },
    {
      "sheet": "A103",
      "page": 86
    },
    {
      "sheet": "A200",
      "page": 87
    },
    {
      "sheet": "A201",
      "page": 88
    },
    {
      "sheet": "A300",
      "page": 89
    },
    {
      "sheet": "S103",
      "page": 95
    },
    {
      "sheet": "S200",
      "page": 96
    },
    {
      "sheet": "S301",
      "page": 98
    }
  ],
  "primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
  "Meghan_concept_pages": [
    6
  ],
  "Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
  "current_opening_units": [
    "W103",
    "W104"
  ],
  "adjoining_wall_inventory": [
    "bed-east",
    "bed2-south-partition",
    "bed1-south-partition",
    "bath-hall-nov03",
    "primary-WC-west",
    "primary-WC-front"
  ],
  "wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
  "ceiling_controls": [
    {
      "id": "primary-bathroom.main-ceiling",
      "room": "primary-bathroom",
      "level": "main",
      "plane_world_z_equals_ax_by_c": [
        0.08333333333333333,
        0,
        267.511666666667
      ],
      "quantity_type": "finished ceiling underside",
      "basis": "Shared source-registered A103/A300bedroom-wing R2slope; independent132.125/151.375in source stations and1:12pitch.",
      "source_class": "Primary source registered nominal plane",
      "not_room_boundary": false,
      "additional_regions": "GreatRoomalso has centralR1approach/side ceilings; primary bath has lower wet enclosure. Read scoped controls, not a single-room height."
    }
  ],
  "later_changes_and_reconciliation": [
    "November3 I104supersedes earlier wet/WC layouts;149.5x138in clear room, registered without scaling. Source42.875in is glass-face clearance;40.75in is half-wall floor clearance.",
    "Common sloped wing ceiling replaces unsupported108.4536in flat proxy. Lower wet enclosure retained.",
    "FAIL/coordination: I104south finishY332.35 versus earlier shellY332.47;0.12in offset remains explicit. Final tile/backing registration must reconcile; no arbitrary fixture rescale."
  ],
  "model_census_by_state": {
    "alcohol": {
      "faces": 5348,
      "object_records": 113
    },
    "espresso": {
      "faces": 5348,
      "object_records": 113
    },
    "espresso-open": {
      "faces": 5348,
      "object_records": 113
    },
    "alcohol-open": {
      "faces": 5348,
      "object_records": 113
    },
    "espresso-operating": {
      "faces": 5348,
      "object_records": 113
    }
  },
  "source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
  "transitions": {
    "T1": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T2": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T3": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T4": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T5": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T6": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T7": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T8": {
      "status": "held",
      "reason": "Property transform/field levels unmeasured"
    },
    "T9": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    }
  },
  "whole_space_qualified": false,
  "image_generation_allowed": false,
  "owner_approval": null
}

Main hall & bedroom thresholds

Source/model qualification: HELD. No new image authorized.

Primary context: A102 p85, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).

Room evidence JSON
{
  "id": "main-hall",
  "title": "Main hall & bedroom thresholds",
  "level": "main",
  "source_aliases": [],
  "primary_plan_context": [
    {
      "sheet": "A102",
      "page": 85
    },
    {
      "sheet": "A103",
      "page": 86
    },
    {
      "sheet": "A200",
      "page": 87
    },
    {
      "sheet": "A201",
      "page": 88
    },
    {
      "sheet": "A300",
      "page": 89
    },
    {
      "sheet": "S103",
      "page": 95
    },
    {
      "sheet": "S200",
      "page": 96
    },
    {
      "sheet": "S301",
      "page": 98
    }
  ],
  "primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
  "Meghan_concept_pages": [],
  "Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
  "current_opening_units": [],
  "adjoining_wall_inventory": [
    "bed2-south-partition",
    "bed1-south-partition",
    "hall-west",
    "powder-north",
    "bath-hall-nov03"
  ],
  "wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
  "ceiling_controls": [
    {
      "id": "main-hall.main-ceiling",
      "room": "main-hall",
      "level": "main",
      "plane_world_z_equals_ax_by_c": [
        0.08333333333333333,
        0,
        267.511666666667
      ],
      "quantity_type": "finished ceiling underside",
      "basis": "Shared source-registered A103/A300bedroom-wing R2slope; independent132.125/151.375in source stations and1:12pitch.",
      "source_class": "Primary source registered nominal plane",
      "not_room_boundary": false,
      "additional_regions": null
    }
  ],
  "later_changes_and_reconciliation": [
    "Later I104hall partition registration retained. Door heads/leaf/hardware fit and whole finished-floor build-up remain unconfirmed."
  ],
  "model_census_by_state": {
    "alcohol": {
      "faces": 8,
      "object_records": 1
    },
    "espresso": {
      "faces": 8,
      "object_records": 1
    },
    "espresso-open": {
      "faces": 8,
      "object_records": 1
    },
    "alcohol-open": {
      "faces": 8,
      "object_records": 1
    },
    "espresso-operating": {
      "faces": 8,
      "object_records": 1
    }
  },
  "source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
  "transitions": {
    "T1": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T2": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T3": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T4": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T5": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T6": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T7": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T8": {
      "status": "held",
      "reason": "Property transform/field levels unmeasured"
    },
    "T9": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    }
  },
  "whole_space_qualified": false,
  "image_generation_allowed": false,
  "owner_approval": null
}

Powder room

Source/model qualification: HELD. No new image authorized.

Primary context: A102 p85, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).

Room evidence JSON
{
  "id": "powder-room",
  "title": "Powder room",
  "level": "main",
  "source_aliases": [],
  "primary_plan_context": [
    {
      "sheet": "A102",
      "page": 85
    },
    {
      "sheet": "A103",
      "page": 86
    },
    {
      "sheet": "A200",
      "page": 87
    },
    {
      "sheet": "A201",
      "page": 88
    },
    {
      "sheet": "A300",
      "page": 89
    },
    {
      "sheet": "S103",
      "page": 95
    },
    {
      "sheet": "S200",
      "page": 96
    },
    {
      "sheet": "S301",
      "page": 98
    }
  ],
  "primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
  "Meghan_concept_pages": [
    5
  ],
  "Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
  "current_opening_units": [
    "W111"
  ],
  "adjoining_wall_inventory": [
    "bed2-west",
    "bed2-south-partition",
    "hall-west",
    "powder-boot-south",
    "powder-boot",
    "powder-north"
  ],
  "wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
  "ceiling_controls": [
    {
      "id": "powder-room.main-ceiling",
      "room": "powder-room",
      "level": "main",
      "plane_world_z_equals_ax_by_c": [
        0,
        0,
        256.125
      ],
      "quantity_type": "finished ceiling underside",
      "basis": "A300centralR1finished-ceiling118.125in; Muskoka underside beam is separately108.5in above main.",
      "source_class": "Primary source registered nominal plane",
      "not_room_boundary": false,
      "additional_regions": null
    }
  ],
  "later_changes_and_reconciliation": [
    "Nominal finished assemblies reconciled; vanity rigidly moved0.51in to fit. Plumbing selection and installed clearances remain open."
  ],
  "model_census_by_state": {
    "alcohol": {
      "faces": 442,
      "object_records": 3
    },
    "espresso": {
      "faces": 442,
      "object_records": 3
    },
    "espresso-open": {
      "faces": 442,
      "object_records": 3
    },
    "alcohol-open": {
      "faces": 442,
      "object_records": 3
    },
    "espresso-operating": {
      "faces": 442,
      "object_records": 3
    }
  },
  "source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
  "transitions": {
    "T1": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T2": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T3": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T4": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T5": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T6": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T7": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T8": {
      "status": "held",
      "reason": "Property transform/field levels unmeasured"
    },
    "T9": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    }
  },
  "whole_space_qualified": false,
  "image_generation_allowed": false,
  "owner_approval": null
}

Boot room / mudroom storage

Source/model qualification: HELD. No new image authorized.

Primary context: A102 p85, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).

Room evidence JSON
{
  "id": "boot-room",
  "title": "Boot room / mudroom storage",
  "level": "main",
  "source_aliases": [],
  "primary_plan_context": [
    {
      "sheet": "A102",
      "page": 85
    },
    {
      "sheet": "A103",
      "page": 86
    },
    {
      "sheet": "A200",
      "page": 87
    },
    {
      "sheet": "A201",
      "page": 88
    },
    {
      "sheet": "A300",
      "page": 89
    },
    {
      "sheet": "S103",
      "page": 95
    },
    {
      "sheet": "S200",
      "page": 96
    },
    {
      "sheet": "S301",
      "page": 98
    }
  ],
  "primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
  "Meghan_concept_pages": [
    3
  ],
  "Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
  "current_opening_units": [
    "W110"
  ],
  "adjoining_wall_inventory": [
    "powder-boot-south",
    "powder-boot",
    "powder-north",
    "entry-south",
    "entry-porch-east"
  ],
  "wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
  "ceiling_controls": [
    {
      "id": "boot-room.main-ceiling",
      "room": "boot-room",
      "level": "main",
      "plane_world_z_equals_ax_by_c": [
        0,
        0,
        256.125
      ],
      "quantity_type": "finished ceiling underside",
      "basis": "A300centralR1finished-ceiling118.125in; Muskoka underside beam is separately108.5in above main.",
      "source_class": "Primary source registered nominal plane",
      "not_room_boundary": false,
      "additional_regions": null
    }
  ],
  "later_changes_and_reconciliation": [
    "Stone entry finish continues through muddy-boot removal area under owner direction. E5east envelope/outward side corrected; actual printed61in clear control passes. Cabinetry is custom proposed fit."
  ],
  "model_census_by_state": {
    "alcohol": {
      "faces": 3512,
      "object_records": 3
    },
    "espresso": {
      "faces": 3512,
      "object_records": 3
    },
    "espresso-open": {
      "faces": 3512,
      "object_records": 3
    },
    "alcohol-open": {
      "faces": 3512,
      "object_records": 3
    },
    "espresso-operating": {
      "faces": 3512,
      "object_records": 3
    }
  },
  "source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
  "transitions": {
    "T1": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T2": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T3": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T4": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T5": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T6": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T7": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T8": {
      "status": "held",
      "reason": "Property transform/field levels unmeasured"
    },
    "T9": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    }
  },
  "whole_space_qualified": false,
  "image_generation_allowed": false,
  "owner_approval": null
}

Main entry

Source/model qualification: HELD. No new image authorized.

Primary context: A102 p85, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).

Room evidence JSON
{
  "id": "entry",
  "title": "Main entry",
  "level": "main",
  "source_aliases": [],
  "primary_plan_context": [
    {
      "sheet": "A102",
      "page": 85
    },
    {
      "sheet": "A103",
      "page": 86
    },
    {
      "sheet": "A200",
      "page": 87
    },
    {
      "sheet": "A201",
      "page": 88
    },
    {
      "sheet": "A300",
      "page": 89
    },
    {
      "sheet": "S103",
      "page": 95
    },
    {
      "sheet": "S200",
      "page": 96
    },
    {
      "sheet": "S301",
      "page": 98
    }
  ],
  "primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
  "Meghan_concept_pages": [
    3
  ],
  "Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
  "current_opening_units": [],
  "adjoining_wall_inventory": [
    "bed2-south-partition",
    "hall-west",
    "powder-boot",
    "powder-north",
    "entry-south",
    "entry-porch-east",
    "entry-porch-west"
  ],
  "wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
  "ceiling_controls": [
    {
      "id": "entry.main-ceiling",
      "room": "entry",
      "level": "main",
      "plane_world_z_equals_ax_by_c": [
        0,
        0,
        251.39
      ],
      "quantity_type": "finished ceiling underside",
      "basis": "Explicit proposed full/flush treatment at correctedSB104underside; owner intent plus131.5in steel top minus source18.11in profile. Services/lining/anchorage remain open.",
      "source_class": "Explicit proposed coordination plane",
      "not_room_boundary": false,
      "additional_regions": null
    }
  ],
  "later_changes_and_reconciliation": [
    "Intentional flush ceiling at proposedSB104underside113.39in above nominal main; structure/finish/services junction needs Nada/Alyssa.",
    "Fluted glass with amber/olive insert retained as appearance direction. Support, stability, attachment and entrance visibility remain design/engineering checks."
  ],
  "model_census_by_state": {
    "alcohol": {
      "faces": 99,
      "object_records": 1
    },
    "espresso": {
      "faces": 99,
      "object_records": 1
    },
    "espresso-open": {
      "faces": 99,
      "object_records": 1
    },
    "alcohol-open": {
      "faces": 99,
      "object_records": 1
    },
    "espresso-operating": {
      "faces": 99,
      "object_records": 1
    }
  },
  "source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
  "transitions": {
    "T1": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T2": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T3": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T4": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T5": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T6": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T7": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T8": {
      "status": "held",
      "reason": "Property transform/field levels unmeasured"
    },
    "T9": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    }
  },
  "whole_space_qualified": false,
  "image_generation_allowed": false,
  "owner_approval": null
}

Kitchen

Source/model qualification: HELD. No new image authorized.

Primary context: A102 p85, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).

Room evidence JSON
{
  "id": "kitchen",
  "title": "Kitchen",
  "level": "main",
  "source_aliases": [],
  "primary_plan_context": [
    {
      "sheet": "A102",
      "page": 85
    },
    {
      "sheet": "A103",
      "page": 86
    },
    {
      "sheet": "A200",
      "page": 87
    },
    {
      "sheet": "A201",
      "page": 88
    },
    {
      "sheet": "A300",
      "page": 89
    },
    {
      "sheet": "S103",
      "page": 95
    },
    {
      "sheet": "S200",
      "page": 96
    },
    {
      "sheet": "S301",
      "page": 98
    }
  ],
  "primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
  "Meghan_concept_pages": [
    2
  ],
  "Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
  "current_opening_units": [
    "W112"
  ],
  "adjoining_wall_inventory": [
    "entry-south",
    "entry-porch-west",
    "registered-west-E1",
    "registered-kitchen-south-E1"
  ],
  "wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
  "ceiling_controls": [
    {
      "id": "kitchen.main-ceiling",
      "room": "kitchen",
      "level": "main",
      "plane_world_z_equals_ax_by_c": [
        0,
        0,
        251.39
      ],
      "quantity_type": "finished ceiling underside",
      "basis": "Explicit proposed full/flush treatment at correctedSB104underside; owner intent plus131.5in steel top minus source18.11in profile. Services/lining/anchorage remain open.",
      "source_class": "Explicit proposed coordination plane",
      "not_room_boundary": false,
      "additional_regions": null
    }
  ],
  "later_changes_and_reconciliation": [
    "Black tapware direction retained; source E1outward side corrected without shrinking pantry. Existing island/stool programme remains a design proposal, not a millwork shop drawing.",
    "Source-sized stools corrected. Appliance/counter-fridge selections and operating/service clearances remain open."
  ],
  "model_census_by_state": {
    "alcohol": {
      "faces": 2253,
      "object_records": 518
    },
    "espresso": {
      "faces": 2253,
      "object_records": 518
    },
    "espresso-open": {
      "faces": 2253,
      "object_records": 518
    },
    "alcohol-open": {
      "faces": 2253,
      "object_records": 518
    },
    "espresso-operating": {
      "faces": 2253,
      "object_records": 518
    }
  },
  "source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
  "transitions": {
    "T1": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T2": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T3": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T4": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T5": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T6": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T7": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T8": {
      "status": "held",
      "reason": "Property transform/field levels unmeasured"
    },
    "T9": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    }
  },
  "whole_space_qualified": false,
  "image_generation_allowed": false,
  "owner_approval": null
}

Great room · living, dining & cozy nook

Source/model qualification: HELD. No new image authorized.

Primary context: A102 p85, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).

Room evidence JSON
{
  "id": "greatroom",
  "title": "Great room · living, dining & cozy nook",
  "level": "main",
  "source_aliases": [],
  "primary_plan_context": [
    {
      "sheet": "A102",
      "page": 85
    },
    {
      "sheet": "A103",
      "page": 86
    },
    {
      "sheet": "A200",
      "page": 87
    },
    {
      "sheet": "A201",
      "page": 88
    },
    {
      "sheet": "A300",
      "page": 89
    },
    {
      "sheet": "S103",
      "page": 95
    },
    {
      "sheet": "S200",
      "page": 96
    },
    {
      "sheet": "S301",
      "page": 98
    }
  ],
  "primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
  "Meghan_concept_pages": [
    4
  ],
  "Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
  "current_opening_units": [
    "W109",
    "TW106",
    "TW107",
    "TW105",
    "TW104",
    "TW103",
    "CW-west-lower",
    "CW-west-upper",
    "CW-east-lower",
    "CW-east-upper",
    "W108"
  ],
  "adjoining_wall_inventory": [
    "hall-west",
    "nook-south",
    "nook-west",
    "registered-west-E1",
    "registered-lake-E1"
  ],
  "wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
  "ceiling_controls": [
    {
      "id": "greatroom.main-ceiling",
      "room": "greatroom",
      "level": "main",
      "plane_world_z_equals_ax_by_c": [
        -0.08333333333333333,
        0,
        346.206666666667
      ],
      "quantity_type": "finished ceiling underside",
      "basis": "A103/A300R2main living slope, independently reconciled148.5/176.125in finished-ceiling stations; source precision retained.",
      "source_class": "Primary source registered nominal plane",
      "not_room_boundary": true,
      "additional_regions": "GreatRoomalso has centralR1approach/side ceilings; primary bath has lower wet enclosure. Read scoped controls, not a single-room height."
    }
  ],
  "later_changes_and_reconciliation": [
    "Current full model has sloped R2living ceiling, corrected scheduled SB103/SB104,589mm horizontal curtain-bank gap and63.5mm vertical gap.",
    "Larger Swoon/floated loveseat preference retained. Real143x67cm Mikado table is parallel to sofa; owned matching JH501pair remain parked overflow.",
    "Alcohol is default. Five complete bar states retained; full conversion/loaded runners/electrical/steam/heat and cabinet support still require actual operation checks.",
    "Nook preferred small Oriel72x72/20in projection remains pending Nada; quote side/centre/depth reconciliation unresolved. OptionCis separate fallback. Rumford configuration unchanged.",
    "Bookcase colours/materials remain on hold in later November12record; do not promote earlier appearance to final material selection."
  ],
  "model_census_by_state": {
    "alcohol": {
      "faces": 38927,
      "object_records": 602
    },
    "espresso": {
      "faces": 38915,
      "object_records": 602
    },
    "espresso-open": {
      "faces": 38932,
      "object_records": 603
    },
    "alcohol-open": {
      "faces": 38944,
      "object_records": 603
    },
    "espresso-operating": {
      "faces": 38915,
      "object_records": 602
    }
  },
  "source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
  "transitions": {
    "T1": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T2": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T3": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T4": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T5": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T6": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T7": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T8": {
      "status": "held",
      "reason": "Property transform/field levels unmeasured"
    },
    "T9": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    }
  },
  "whole_space_qualified": false,
  "image_generation_allowed": false,
  "owner_approval": null
}

Three-season Muskoka room

Source/model qualification: HELD. No new image authorized.

Primary context: A102 p85, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).

Room evidence JSON
{
  "id": "muskoka-room",
  "title": "Three-season Muskoka room",
  "level": "main",
  "source_aliases": [],
  "primary_plan_context": [
    {
      "sheet": "A102",
      "page": 85
    },
    {
      "sheet": "A103",
      "page": 86
    },
    {
      "sheet": "A200",
      "page": 87
    },
    {
      "sheet": "A201",
      "page": 88
    },
    {
      "sheet": "A300",
      "page": 89
    },
    {
      "sheet": "S103",
      "page": 95
    },
    {
      "sheet": "S200",
      "page": 96
    },
    {
      "sheet": "S301",
      "page": 98
    }
  ],
  "primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
  "Meghan_concept_pages": [],
  "Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
  "current_opening_units": [],
  "adjoining_wall_inventory": [
    "registered-west-E1"
  ],
  "wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
  "ceiling_controls": [
    {
      "id": "muskoka-room.main-ceiling",
      "room": "muskoka-room",
      "level": "main",
      "plane_world_z_equals_ax_by_c": [
        0,
        0,
        256.125
      ],
      "quantity_type": "finished ceiling underside",
      "basis": "A300centralR1finished-ceiling118.125in; Muskoka underside beam is separately108.5in above main.",
      "source_class": "Primary source registered nominal plane",
      "not_room_boundary": false,
      "additional_regions": null
    }
  ],
  "later_changes_and_reconciliation": [
    "E101actual rough width131.75in, same main floor and north/lake fold direction. Exact head/sill/track/support and stack-jamb tolerance pending.",
    "E102single outswing pushed toward kitchen is a November11suggestion explicitly not ordered; preserve existing double/screen study."
  ],
  "model_census_by_state": {
    "alcohol": {
      "faces": 1326,
      "object_records": 8
    },
    "espresso": {
      "faces": 1326,
      "object_records": 8
    },
    "espresso-open": {
      "faces": 1326,
      "object_records": 8
    },
    "alcohol-open": {
      "faces": 1326,
      "object_records": 8
    },
    "espresso-operating": {
      "faces": 1326,
      "object_records": 8
    }
  },
  "source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
  "transitions": {
    "T1": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T2": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T3": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T4": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T5": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T6": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T7": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T8": {
      "status": "held",
      "reason": "Property transform/field levels unmeasured"
    },
    "T9": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    }
  },
  "whole_space_qualified": false,
  "image_generation_allowed": false,
  "owner_approval": null
}

Mechanical room

Source/model qualification: HELD. No new image authorized.

Primary context: A101 p84, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).

Room evidence JSON
{
  "id": "mechanical-room",
  "title": "Mechanical room",
  "level": "basement",
  "source_aliases": [],
  "primary_plan_context": [
    {
      "sheet": "A101",
      "page": 84
    },
    {
      "sheet": "A103",
      "page": 86
    },
    {
      "sheet": "A200",
      "page": 87
    },
    {
      "sheet": "A201",
      "page": 88
    },
    {
      "sheet": "A300",
      "page": 89
    },
    {
      "sheet": "S103",
      "page": 95
    },
    {
      "sheet": "S200",
      "page": 96
    },
    {
      "sheet": "S301",
      "page": 98
    }
  ],
  "primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
  "Meghan_concept_pages": [],
  "Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
  "current_opening_units": [],
  "adjoining_wall_inventory": [
    "foundation-east",
    "foundation-south",
    "foundation-mech-west",
    "mech-bed4",
    "mech-hall",
    "bath-east",
    "hall-bath-north",
    "wing-east-B1-lining",
    "mech-south-B1-lining"
  ],
  "wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
  "ceiling_controls": [
    {
      "id": "mechanical-room.main-ceiling",
      "room": "mechanical-room",
      "level": "basement",
      "plane_world_z_equals_ax_by_c": [
        0,
        0,
        108.0
      ],
      "quantity_type": "finished ceiling underside",
      "basis": "A300printed9ft finished basement ceiling; room uses that shared dropped-ceiling plane.",
      "source_class": "Primary source registered nominal plane",
      "not_room_boundary": false,
      "additional_regions": null
    }
  ],
  "later_changes_and_reconciliation": [
    "A101113.375in substrate chain minus separate2in B1gives111.375in occupied clear; do not conflate quantities.",
    "15in combined printed chain versus F2+B1nominal15.25in remains a source conflict. Mechanical systems/service clearances unselected."
  ],
  "model_census_by_state": {
    "alcohol": {
      "faces": 26,
      "object_records": 1
    },
    "espresso": {
      "faces": 26,
      "object_records": 1
    },
    "espresso-open": {
      "faces": 26,
      "object_records": 1
    },
    "alcohol-open": {
      "faces": 26,
      "object_records": 1
    },
    "espresso-operating": {
      "faces": 26,
      "object_records": 1
    }
  },
  "source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
  "transitions": {
    "T1": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T2": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T3": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T4": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T5": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T6": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T7": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T8": {
      "status": "held",
      "reason": "Property transform/field levels unmeasured"
    },
    "T9": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    }
  },
  "whole_space_qualified": false,
  "image_generation_allowed": false,
  "owner_approval": null
}

Bedroom 4

Source/model qualification: HELD. No new image authorized.

Primary context: A101 p84, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).

Room evidence JSON
{
  "id": "bedroom4",
  "title": "Bedroom 4",
  "level": "basement",
  "source_aliases": [],
  "primary_plan_context": [
    {
      "sheet": "A101",
      "page": 84
    },
    {
      "sheet": "A103",
      "page": 86
    },
    {
      "sheet": "A200",
      "page": 87
    },
    {
      "sheet": "A201",
      "page": 88
    },
    {
      "sheet": "A300",
      "page": 89
    },
    {
      "sheet": "S103",
      "page": 95
    },
    {
      "sheet": "S200",
      "page": 96
    },
    {
      "sheet": "S301",
      "page": 98
    }
  ],
  "primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
  "Meghan_concept_pages": [],
  "Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
  "current_opening_units": [
    "W001"
  ],
  "adjoining_wall_inventory": [
    "foundation-east",
    "mech-bed4",
    "mech-hall",
    "bed4-hall",
    "bed4-alcove",
    "bed4-storage",
    "bed4-ensuite",
    "wing-east-B1-lining"
  ],
  "wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
  "ceiling_controls": [
    {
      "id": "bedroom4.main-ceiling",
      "room": "bedroom4",
      "level": "basement",
      "plane_world_z_equals_ax_by_c": [
        0,
        0,
        108.0
      ],
      "quantity_type": "finished ceiling underside",
      "basis": "A300printed9ft finished basement ceiling; room uses that shared dropped-ceiling plane.",
      "source_class": "Primary source registered nominal plane",
      "not_room_boundary": false,
      "additional_regions": null
    }
  ],
  "later_changes_and_reconciliation": [
    "Source I2hall/alcove and4.5in bed/ensuite partition assignments reconciled. No newly ordered Harper window belongs here. Wardrobe is custom site-fit proposal."
  ],
  "model_census_by_state": {
    "alcohol": {
      "faces": 1171,
      "object_records": 9
    },
    "espresso": {
      "faces": 1171,
      "object_records": 9
    },
    "espresso-open": {
      "faces": 1171,
      "object_records": 9
    },
    "alcohol-open": {
      "faces": 1171,
      "object_records": 9
    },
    "espresso-operating": {
      "faces": 1171,
      "object_records": 9
    }
  },
  "source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
  "transitions": {
    "T1": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T2": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T3": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T4": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T5": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T6": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T7": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T8": {
      "status": "held",
      "reason": "Property transform/field levels unmeasured"
    },
    "T9": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    }
  },
  "whole_space_qualified": false,
  "image_generation_allowed": false,
  "owner_approval": null
}

Basement hall

Source/model qualification: HELD. No new image authorized.

Primary context: A101 p84, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).

Room evidence JSON
{
  "id": "basement-hall",
  "title": "Basement hall",
  "level": "basement",
  "source_aliases": [],
  "primary_plan_context": [
    {
      "sheet": "A101",
      "page": 84
    },
    {
      "sheet": "A103",
      "page": 86
    },
    {
      "sheet": "A200",
      "page": 87
    },
    {
      "sheet": "A201",
      "page": 88
    },
    {
      "sheet": "A300",
      "page": 89
    },
    {
      "sheet": "S103",
      "page": 95
    },
    {
      "sheet": "S200",
      "page": 96
    },
    {
      "sheet": "S301",
      "page": 98
    }
  ],
  "primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
  "Meghan_concept_pages": [],
  "Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
  "current_opening_units": [],
  "adjoining_wall_inventory": [
    "mech-hall",
    "hall-bath-north",
    "bed4-hall",
    "bed4-storage",
    "wing-hall"
  ],
  "wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
  "ceiling_controls": [
    {
      "id": "basement-hall.main-ceiling",
      "room": "basement-hall",
      "level": "basement",
      "plane_world_z_equals_ax_by_c": [
        0,
        0,
        108.0
      ],
      "quantity_type": "finished ceiling underside",
      "basis": "A300printed9ft finished basement ceiling; room uses that shared dropped-ceiling plane.",
      "source_class": "Primary source registered nominal plane",
      "not_room_boundary": false,
      "additional_regions": null
    }
  ],
  "later_changes_and_reconciliation": [
    "I2/I2.1source type arrows and adjoining bathroom/bedroom finish planes reconciled. Hall travel/door swing/threshold sweep still needs full operation acceptance."
  ],
  "model_census_by_state": {
    "alcohol": {
      "faces": 8,
      "object_records": 1
    },
    "espresso": {
      "faces": 8,
      "object_records": 1
    },
    "espresso-open": {
      "faces": 8,
      "object_records": 1
    },
    "alcohol-open": {
      "faces": 8,
      "object_records": 1
    },
    "espresso-operating": {
      "faces": 8,
      "object_records": 1
    }
  },
  "source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
  "transitions": {
    "T1": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T2": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T3": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T4": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T5": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T6": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T7": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T8": {
      "status": "held",
      "reason": "Property transform/field levels unmeasured"
    },
    "T9": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    }
  },
  "whole_space_qualified": false,
  "image_generation_allowed": false,
  "owner_approval": null
}

Basement shared bathroom

Source/model qualification: HELD. No new image authorized.

Primary context: A101 p84, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).

Room evidence JSON
{
  "id": "basement-bathroom",
  "title": "Basement shared bathroom",
  "level": "basement",
  "source_aliases": [],
  "primary_plan_context": [
    {
      "sheet": "A101",
      "page": 84
    },
    {
      "sheet": "A103",
      "page": 86
    },
    {
      "sheet": "A200",
      "page": 87
    },
    {
      "sheet": "A201",
      "page": 88
    },
    {
      "sheet": "A300",
      "page": 89
    },
    {
      "sheet": "S103",
      "page": 95
    },
    {
      "sheet": "S200",
      "page": 96
    },
    {
      "sheet": "S301",
      "page": 98
    }
  ],
  "primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
  "Meghan_concept_pages": [
    10
  ],
  "Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
  "current_opening_units": [],
  "adjoining_wall_inventory": [
    "foundation-bath-south",
    "foundation-entry-east",
    "bath-east",
    "hall-bath-north",
    "bath-south-finish-lining",
    "bath-laundry-return"
  ],
  "wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
  "ceiling_controls": [
    {
      "id": "basement-bathroom.main-ceiling",
      "room": "basement-bathroom",
      "level": "basement",
      "plane_world_z_equals_ax_by_c": [
        0,
        0,
        108.0
      ],
      "quantity_type": "finished ceiling underside",
      "basis": "A300printed9ft finished basement ceiling; room uses that shared dropped-ceiling plane.",
      "source_class": "Primary source registered nominal plane",
      "not_room_boundary": false,
      "additional_regions": null
    }
  ],
  "later_changes_and_reconciliation": [
    "Missing bath/laundry return restored from A101actual paths. Net area62.892SFagrees with rounded63SFsecondary label.",
    "South B2particular assignment remains inferred. Tub/vanity moved rigidly to fit; final plumbing/fixture and wet installation not selected."
  ],
  "model_census_by_state": {
    "alcohol": {
      "faces": 802,
      "object_records": 5
    },
    "espresso": {
      "faces": 802,
      "object_records": 5
    },
    "espresso-open": {
      "faces": 802,
      "object_records": 5
    },
    "alcohol-open": {
      "faces": 802,
      "object_records": 5
    },
    "espresso-operating": {
      "faces": 802,
      "object_records": 5
    }
  },
  "source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
  "transitions": {
    "T1": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T2": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T3": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T4": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T5": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T6": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T7": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T8": {
      "status": "held",
      "reason": "Property transform/field levels unmeasured"
    },
    "T9": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    }
  },
  "whole_space_qualified": false,
  "image_generation_allowed": false,
  "owner_approval": null
}

Bedroom 3 ensuite

Source/model qualification: HELD. No new image authorized.

Primary context: A101 p84, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).

Room evidence JSON
{
  "id": "ensuite3",
  "title": "Bedroom 3 ensuite",
  "level": "basement",
  "source_aliases": [],
  "primary_plan_context": [
    {
      "sheet": "A101",
      "page": 84
    },
    {
      "sheet": "A103",
      "page": 86
    },
    {
      "sheet": "A200",
      "page": 87
    },
    {
      "sheet": "A201",
      "page": 88
    },
    {
      "sheet": "A300",
      "page": 89
    },
    {
      "sheet": "S103",
      "page": 95
    },
    {
      "sheet": "S200",
      "page": 96
    },
    {
      "sheet": "S301",
      "page": 98
    }
  ],
  "primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
  "Meghan_concept_pages": [],
  "Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
  "current_opening_units": [
    "W002"
  ],
  "adjoining_wall_inventory": [
    "foundation-east",
    "bed4-ensuite",
    "ensuite-wic",
    "ensuite-bedroom3",
    "wing-east-B1-lining"
  ],
  "wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
  "ceiling_controls": [
    {
      "id": "ensuite3.main-ceiling",
      "room": "ensuite3",
      "level": "basement",
      "plane_world_z_equals_ax_by_c": [
        0,
        0,
        108.0
      ],
      "quantity_type": "finished ceiling underside",
      "basis": "A300printed9ft finished basement ceiling; room uses that shared dropped-ceiling plane.",
      "source_class": "Primary source registered nominal plane",
      "not_room_boundary": false,
      "additional_regions": null
    }
  ],
  "later_changes_and_reconciliation": [
    "A10166in depth control passes;48x24in vanity rigidly moved beyond B1face. Custom shower/storage fitted to source finish bounds; exact products/plumbing/operation remain open."
  ],
  "model_census_by_state": {
    "alcohol": {
      "faces": 468,
      "object_records": 11
    },
    "espresso": {
      "faces": 468,
      "object_records": 11
    },
    "espresso-open": {
      "faces": 468,
      "object_records": 11
    },
    "alcohol-open": {
      "faces": 468,
      "object_records": 11
    },
    "espresso-operating": {
      "faces": 468,
      "object_records": 11
    }
  },
  "source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
  "transitions": {
    "T1": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T2": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T3": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T4": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T5": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T6": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T7": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T8": {
      "status": "held",
      "reason": "Property transform/field levels unmeasured"
    },
    "T9": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    }
  },
  "whole_space_qualified": false,
  "image_generation_allowed": false,
  "owner_approval": null
}

Basement walk-in storage

Source/model qualification: HELD. No new image authorized.

Primary context: A101 p84, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).

Room evidence JSON
{
  "id": "basement-wic",
  "title": "Basement walk-in storage",
  "level": "basement",
  "source_aliases": [],
  "primary_plan_context": [
    {
      "sheet": "A101",
      "page": 84
    },
    {
      "sheet": "A103",
      "page": 86
    },
    {
      "sheet": "A200",
      "page": 87
    },
    {
      "sheet": "A201",
      "page": 88
    },
    {
      "sheet": "A300",
      "page": 89
    },
    {
      "sheet": "S103",
      "page": 95
    },
    {
      "sheet": "S200",
      "page": 96
    },
    {
      "sheet": "S301",
      "page": 98
    }
  ],
  "primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
  "Meghan_concept_pages": [],
  "Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
  "current_opening_units": [],
  "adjoining_wall_inventory": [
    "bed4-ensuite",
    "ensuite-wic",
    "ensuite-bedroom3",
    "wing-hall"
  ],
  "wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
  "ceiling_controls": [
    {
      "id": "basement-wic.main-ceiling",
      "room": "basement-wic",
      "level": "basement",
      "plane_world_z_equals_ax_by_c": [
        0,
        0,
        108.0
      ],
      "quantity_type": "finished ceiling underside",
      "basis": "A300printed9ft finished basement ceiling; room uses that shared dropped-ceiling plane.",
      "source_class": "Primary source registered nominal plane",
      "not_room_boundary": false,
      "additional_regions": null
    }
  ],
  "later_changes_and_reconciliation": [
    "Primary partition envelope retained; custom shelves/wardrobes fitted to actual finish faces. Internal working/door/loaded storage dimensions remain proposals."
  ],
  "model_census_by_state": {
    "alcohol": {
      "faces": 122,
      "object_records": 1
    },
    "espresso": {
      "faces": 122,
      "object_records": 1
    },
    "espresso-open": {
      "faces": 122,
      "object_records": 1
    },
    "alcohol-open": {
      "faces": 122,
      "object_records": 1
    },
    "espresso-operating": {
      "faces": 122,
      "object_records": 1
    }
  },
  "source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
  "transitions": {
    "T1": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T2": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T3": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T4": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T5": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T6": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T7": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T8": {
      "status": "held",
      "reason": "Property transform/field levels unmeasured"
    },
    "T9": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    }
  },
  "whole_space_qualified": false,
  "image_generation_allowed": false,
  "owner_approval": null
}

Bedroom 3

Source/model qualification: HELD. No new image authorized.

Primary context: A101 p84, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).

Room evidence JSON
{
  "id": "bedroom3",
  "title": "Bedroom 3",
  "level": "basement",
  "source_aliases": [
    "Harper bedroom"
  ],
  "primary_plan_context": [
    {
      "sheet": "A101",
      "page": 84
    },
    {
      "sheet": "A103",
      "page": 86
    },
    {
      "sheet": "A200",
      "page": 87
    },
    {
      "sheet": "A201",
      "page": 88
    },
    {
      "sheet": "A300",
      "page": 89
    },
    {
      "sheet": "S103",
      "page": 95
    },
    {
      "sheet": "S200",
      "page": 96
    },
    {
      "sheet": "S301",
      "page": 98
    }
  ],
  "primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
  "Meghan_concept_pages": [],
  "Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
  "current_opening_units": [
    "W003",
    "EST-B3-WOODS-01"
  ],
  "adjoining_wall_inventory": [
    "foundation-east",
    "bedroom3-north",
    "walkout-north",
    "walkout-east",
    "ensuite-bedroom3",
    "wing-hall",
    "wing-east-B1-lining",
    "bedroom3-east-B2-lining"
  ],
  "wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
  "ceiling_controls": [
    {
      "id": "bedroom3.main-ceiling",
      "room": "bedroom3",
      "level": "basement",
      "plane_world_z_equals_ax_by_c": [
        0,
        0,
        108.0
      ],
      "quantity_type": "finished ceiling underside",
      "basis": "A300printed9ft finished basement ceiling; room uses that shared dropped-ceiling plane.",
      "source_class": "Primary source registered nominal plane",
      "not_room_boundary": false,
      "additional_regions": null
    }
  ],
  "later_changes_and_reconciliation": [
    "Harper additional woods-facing window: owner authorizes best-information location estimate; centred east wall with proposed matching W002family25x36in/sill48in. Not a tagged order or engineering approval.",
    "A101213.25in to substrate minus4in B2gives209.25in occupied width;123.25in depth. Approx179.1SFsecondary area agrees with179SFlabel."
  ],
  "model_census_by_state": {
    "alcohol": {
      "faces": 1206,
      "object_records": 3
    },
    "espresso": {
      "faces": 1206,
      "object_records": 3
    },
    "espresso-open": {
      "faces": 1206,
      "object_records": 3
    },
    "alcohol-open": {
      "faces": 1206,
      "object_records": 3
    },
    "espresso-operating": {
      "faces": 1206,
      "object_records": 3
    }
  },
  "source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
  "transitions": {
    "T1": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T2": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T3": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T4": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T5": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T6": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T7": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T8": {
      "status": "held",
      "reason": "Property transform/field levels unmeasured"
    },
    "T9": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    }
  },
  "whole_space_qualified": false,
  "image_generation_allowed": false,
  "owner_approval": null
}

Lower entry & stair arrival

Source/model qualification: HELD. No new image authorized.

Primary context: A101 p84, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).

Room evidence JSON
{
  "id": "lower-entry",
  "title": "Lower entry & stair arrival",
  "level": "basement",
  "source_aliases": [],
  "primary_plan_context": [
    {
      "sheet": "A101",
      "page": 84
    },
    {
      "sheet": "A103",
      "page": 86
    },
    {
      "sheet": "A200",
      "page": 87
    },
    {
      "sheet": "A201",
      "page": 88
    },
    {
      "sheet": "A300",
      "page": 89
    },
    {
      "sheet": "S103",
      "page": 95
    },
    {
      "sheet": "S200",
      "page": 96
    },
    {
      "sheet": "S301",
      "page": 98
    }
  ],
  "primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
  "Meghan_concept_pages": [],
  "Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
  "current_opening_units": [
    "E002"
  ],
  "adjoining_wall_inventory": [
    "walkout-north",
    "hall-bath-north",
    "wing-hall",
    "hall-laundry",
    "rec-hall"
  ],
  "wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
  "ceiling_controls": [
    {
      "id": "lower-entry.main-ceiling",
      "room": "lower-entry",
      "level": "basement",
      "plane_world_z_equals_ax_by_c": [
        0,
        0,
        108.0
      ],
      "quantity_type": "finished ceiling underside",
      "basis": "A300printed9ft finished basement ceiling; room uses that shared dropped-ceiling plane.",
      "source_class": "Primary source registered nominal plane",
      "not_room_boundary": false,
      "additional_regions": null
    }
  ],
  "later_changes_and_reconciliation": [
    "W007owner alias lower-entry-side window is physically the RecRoom recess casement; no extra RecRoomwindow is invented.",
    "Basement108in ceiling restored over lower stair region per A102opening. Exact threshold/floor build-up and property-grade transform remain open."
  ],
  "model_census_by_state": {
    "alcohol": {
      "faces": 57,
      "object_records": 1
    },
    "espresso": {
      "faces": 57,
      "object_records": 1
    },
    "espresso-open": {
      "faces": 57,
      "object_records": 1
    },
    "alcohol-open": {
      "faces": 57,
      "object_records": 1
    },
    "espresso-operating": {
      "faces": 57,
      "object_records": 1
    }
  },
  "source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
  "transitions": {
    "T1": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T2": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T3": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T4": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T5": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T6": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T7": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T8": {
      "status": "held",
      "reason": "Property transform/field levels unmeasured"
    },
    "T9": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    }
  },
  "whole_space_qualified": false,
  "image_generation_allowed": false,
  "owner_approval": null
}

Basement laundry

Source/model qualification: HELD. No new image authorized.

Primary context: A101 p84, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).

Room evidence JSON
{
  "id": "basement-laundry",
  "title": "Basement laundry",
  "level": "basement",
  "source_aliases": [],
  "primary_plan_context": [
    {
      "sheet": "A101",
      "page": 84
    },
    {
      "sheet": "A103",
      "page": 86
    },
    {
      "sheet": "A200",
      "page": 87
    },
    {
      "sheet": "A201",
      "page": 88
    },
    {
      "sheet": "A300",
      "page": 89
    },
    {
      "sheet": "S103",
      "page": 95
    },
    {
      "sheet": "S200",
      "page": 96
    },
    {
      "sheet": "S301",
      "page": 98
    }
  ],
  "primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
  "Meghan_concept_pages": [
    11
  ],
  "Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
  "current_opening_units": [],
  "adjoining_wall_inventory": [
    "foundation-entry-north",
    "hall-bath-north",
    "hall-laundry",
    "laundry-north",
    "laundry-media",
    "bath-laundry-return"
  ],
  "wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
  "ceiling_controls": [
    {
      "id": "basement-laundry.main-ceiling",
      "room": "basement-laundry",
      "level": "basement",
      "plane_world_z_equals_ax_by_c": [
        0,
        0,
        108.0
      ],
      "quantity_type": "finished ceiling underside",
      "basis": "A300printed9ft finished basement ceiling; room uses that shared dropped-ceiling plane.",
      "source_class": "Primary source registered nominal plane",
      "not_room_boundary": false,
      "additional_regions": null
    }
  ],
  "later_changes_and_reconciliation": [
    "Actual source bathroom return and north I1partition reconciled; machines moved rigidly0.2in; custom counter/hanging storage fitted. Appliance/service/door operation remains unselected."
  ],
  "model_census_by_state": {
    "alcohol": {
      "faces": 538,
      "object_records": 27
    },
    "espresso": {
      "faces": 538,
      "object_records": 27
    },
    "espresso-open": {
      "faces": 538,
      "object_records": 27
    },
    "alcohol-open": {
      "faces": 538,
      "object_records": 27
    },
    "espresso-operating": {
      "faces": 538,
      "object_records": 27
    }
  },
  "source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
  "transitions": {
    "T1": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T2": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T3": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T4": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T5": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T6": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T7": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T8": {
      "status": "held",
      "reason": "Property transform/field levels unmeasured"
    },
    "T9": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    }
  },
  "whole_space_qualified": false,
  "image_generation_allowed": false,
  "owner_approval": null
}

Golf simulator & media room

Source/model qualification: HELD. No new image authorized.

Primary context: A101 p84, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).

Room evidence JSON
{
  "id": "media-room",
  "title": "Golf simulator & media room",
  "level": "basement",
  "source_aliases": [],
  "primary_plan_context": [
    {
      "sheet": "A101",
      "page": 84
    },
    {
      "sheet": "A103",
      "page": 86
    },
    {
      "sheet": "A200",
      "page": 87
    },
    {
      "sheet": "A201",
      "page": 88
    },
    {
      "sheet": "A300",
      "page": 89
    },
    {
      "sheet": "S103",
      "page": 95
    },
    {
      "sheet": "S200",
      "page": 96
    },
    {
      "sheet": "S301",
      "page": 98
    }
  ],
  "primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
  "Meghan_concept_pages": [],
  "Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
  "current_opening_units": [],
  "adjoining_wall_inventory": [
    "foundation-entry-west",
    "foundation-media-south",
    "foundation-west",
    "laundry-media",
    "media-rec",
    "media-B1-lining",
    "media-south-B1-lining"
  ],
  "wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
  "ceiling_controls": [
    {
      "id": "media-room.main-ceiling",
      "room": "media-room",
      "level": "basement",
      "plane_world_z_equals_ax_by_c": [
        0,
        0,
        125.0
      ],
      "quantity_type": "finished ceiling underside",
      "basis": "A101no dropped ceiling; A300125.5in framing less explicitly inferred0.5in finish.",
      "source_class": "Explicit proposed coordination plane",
      "not_room_boundary": false,
      "additional_regions": null
    }
  ],
  "later_changes_and_reconciliation": [
    "A101NO DROPPED CEILING: current125in finish study is125.5in framing less inferred0.5in lining. Services/finish thickness open.",
    "189.125in width and122.625in substrate depth minus2in B1=120.625in occupied depth. Golf simulator/swing/equipment specifications still need actual-size operational study."
  ],
  "model_census_by_state": {
    "alcohol": {
      "faces": 62,
      "object_records": 1
    },
    "espresso": {
      "faces": 62,
      "object_records": 1
    },
    "espresso-open": {
      "faces": 62,
      "object_records": 1
    },
    "alcohol-open": {
      "faces": 62,
      "object_records": 1
    },
    "espresso-operating": {
      "faces": 62,
      "object_records": 1
    }
  },
  "source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
  "transitions": {
    "T1": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T2": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T3": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T4": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T5": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T6": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T7": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T8": {
      "status": "held",
      "reason": "Property transform/field levels unmeasured"
    },
    "T9": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    }
  },
  "whole_space_qualified": false,
  "image_generation_allowed": false,
  "owner_approval": null
}

Rec room, lounge & stowaway guest bunks

Source/model qualification: HELD. No new image authorized.

Primary context: A101 p84, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).

Room evidence JSON
{
  "id": "rec-room",
  "title": "Rec room, lounge & stowaway guest bunks",
  "level": "basement",
  "source_aliases": [],
  "primary_plan_context": [
    {
      "sheet": "A101",
      "page": 84
    },
    {
      "sheet": "A103",
      "page": 86
    },
    {
      "sheet": "A200",
      "page": 87
    },
    {
      "sheet": "A201",
      "page": 88
    },
    {
      "sheet": "A300",
      "page": 89
    },
    {
      "sheet": "S103",
      "page": 95
    },
    {
      "sheet": "S200",
      "page": 96
    },
    {
      "sheet": "S301",
      "page": 98
    }
  ],
  "primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
  "Meghan_concept_pages": [],
  "Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
  "current_opening_units": [
    "W004",
    "W005",
    "W006",
    "E004",
    "W007"
  ],
  "adjoining_wall_inventory": [
    "foundation-west",
    "rec-north",
    "walkout-north",
    "walkout-west",
    "hall-laundry",
    "laundry-north",
    "media-rec",
    "rec-hall",
    "rec-B1-lining"
  ],
  "wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
  "ceiling_controls": [
    {
      "id": "rec-room.main-ceiling",
      "room": "rec-room",
      "level": "basement",
      "plane_world_z_equals_ax_by_c": [
        0,
        0,
        108.0
      ],
      "quantity_type": "finished ceiling underside",
      "basis": "A300printed9ft finished basement ceiling; room uses that shared dropped-ceiling plane.",
      "source_class": "Primary source registered nominal plane",
      "not_room_boundary": false,
      "additional_regions": null
    }
  ],
  "later_changes_and_reconciliation": [
    "333.375in occupied width is335.375in printed substrate span minus2in B1. Depth222.125in retained; approx514.3SFagrees with rounded514SFsecondary label.",
    "W007baseline24x72in added in November11programme; updated order/profile not supplied. Interior rec-hall wrongly continued across it; corrected to stop at source walkout-north closure.",
    "Stowaway bunks/guest/TV fixtures remain design proposals requiring actual products, loaded/occupied operation and final clearances."
  ],
  "model_census_by_state": {
    "alcohol": {
      "faces": 1382,
      "object_records": 7
    },
    "espresso": {
      "faces": 1382,
      "object_records": 7
    },
    "espresso-open": {
      "faces": 1382,
      "object_records": 7
    },
    "alcohol-open": {
      "faces": 1382,
      "object_records": 7
    },
    "espresso-operating": {
      "faces": 1382,
      "object_records": 7
    }
  },
  "source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
  "transitions": {
    "T1": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T2": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T3": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T4": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T5": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T6": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T7": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T8": {
      "status": "held",
      "reason": "Property transform/field levels unmeasured"
    },
    "T9": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    }
  },
  "whole_space_qualified": false,
  "image_generation_allowed": false,
  "owner_approval": null
}

Interior stairs & landings

Source/model qualification: HELD. No new image authorized.

Primary context: A101 p84, A102 p85, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).

Room evidence JSON
{
  "id": "stairs",
  "title": "Interior stairs & landings",
  "level": "both",
  "source_aliases": [],
  "primary_plan_context": [
    {
      "sheet": "A101",
      "page": 84
    },
    {
      "sheet": "A102",
      "page": 85
    },
    {
      "sheet": "A103",
      "page": 86
    },
    {
      "sheet": "A200",
      "page": 87
    },
    {
      "sheet": "A201",
      "page": 88
    },
    {
      "sheet": "A300",
      "page": 89
    },
    {
      "sheet": "S103",
      "page": 95
    },
    {
      "sheet": "S200",
      "page": 96
    },
    {
      "sheet": "S301",
      "page": 98
    }
  ],
  "primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
  "Meghan_concept_pages": [
    9
  ],
  "Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
  "current_opening_units": [],
  "adjoining_wall_inventory": [],
  "wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
  "ceiling_controls": [],
  "later_changes_and_reconciliation": [
    "18actual upper tread surfaces;18th is main-floor landing.138/18in nominal riser;10in going;46.48in tread width.",
    "270nosing-adjacent/midgoing width probes give minimum77.33333in model clearance. Source1950mmcontrol remains separate; continuous sweep/rails/landing/channel/installation and code certification not established."
  ],
  "model_census_by_state": {
    "alcohol": {
      "faces": 1008,
      "object_records": 0
    },
    "espresso": {
      "faces": 1008,
      "object_records": 0
    },
    "espresso-open": {
      "faces": 1008,
      "object_records": 0
    },
    "alcohol-open": {
      "faces": 1008,
      "object_records": 0
    },
    "espresso-operating": {
      "faces": 1008,
      "object_records": 0
    }
  },
  "source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
  "transitions": {
    "T1": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T2": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T3": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T4": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T5": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T6": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T7": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T8": {
      "status": "held",
      "reason": "Property transform/field levels unmeasured"
    },
    "T9": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    }
  },
  "whole_space_qualified": false,
  "image_generation_allowed": false,
  "owner_approval": null
}

Decks, porches & exterior thresholds

Source/model qualification: HELD. No new image authorized.

Primary context: A102 p85, A103 p86, A200 p87, A201 p88, A300 p89, S103 p95, S200 p96, S301 p98 (one-based PDF pages).

Room evidence JSON
{
  "id": "decks-porches",
  "title": "Decks, porches & exterior thresholds",
  "level": "exterior",
  "source_aliases": [],
  "primary_plan_context": [
    {
      "sheet": "A102",
      "page": 85
    },
    {
      "sheet": "A103",
      "page": 86
    },
    {
      "sheet": "A200",
      "page": 87
    },
    {
      "sheet": "A201",
      "page": 88
    },
    {
      "sheet": "A300",
      "page": 89
    },
    {
      "sheet": "S103",
      "page": 95
    },
    {
      "sheet": "S200",
      "page": 96
    },
    {
      "sheet": "S301",
      "page": 98
    }
  ],
  "primary_page_numbering": "One-based PDF page numbers, not zero-based historical metadata indexes.",
  "Meghan_concept_pages": [],
  "Meghan_scope": "Appearance/programme reference only, not dimension authority. Empty list means no dedicated room page in the September22concept.",
  "current_opening_units": [],
  "adjoining_wall_inventory": [],
  "wall_association_rule": "Within2in of current review region, which is a reading aid and not measured room clearance. Includes nearby/interface walls intentionally.",
  "ceiling_controls": [],
  "later_changes_and_reconciliation": [
    "Interior coordinate origin is not surveyed property registration. Source thresholds/roof/guards/footprints remain separate from terrain/root/permission evidence.",
    "Property Studio remains the GEEKOMsingle writer; current curated exterior package is the November13Synology export. No geometry/state copied back or changed."
  ],
  "model_census_by_state": {
    "alcohol": {
      "faces": 3615,
      "object_records": 6
    },
    "espresso": {
      "faces": 3615,
      "object_records": 6
    },
    "espresso-open": {
      "faces": 3615,
      "object_records": 6
    },
    "alcohol-open": {
      "faces": 3615,
      "object_records": 6
    },
    "espresso-operating": {
      "faces": 3615,
      "object_records": 6
    }
  },
  "source_coverage": "Primary context located and room reconciliation recorded; complete independent source/quantity/operation population not yet accepted.",
  "transitions": {
    "T1": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T2": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T3": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T4": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T5": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T6": {
      "status": "not run / upstream measurement hold",
      "reason": "No new native render/design image authorized before model validation"
    },
    "T7": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    },
    "T8": {
      "status": "held",
      "reason": "Property transform/field levels unmeasured"
    },
    "T9": {
      "status": "held",
      "reason": "Complete room source/quantity/operation and current release acceptance required"
    }
  },
  "whole_space_qualified": false,
  "image_generation_allowed": false,
  "owner_approval": null
}
Coordination questions · drafts only, nothing sent
DRAFT ONLY — nothing sent; no owner or engineering approval. Current source findings supersede historical open-question wording.

1. Nada / Alyssa / Meghan — common roof, timber, steel and finish section
Scheduled SB103 top 158.5 in andSB104 top 131.5 in are restored. Coordinate rolled profiles, C103 plates/cut, full-width nailer thickness, timber bearing/exposure, services, finish-floor build-up and the intentional fully flush/below kitchen-entry ceiling. Current flush study is 113.39 in above nominal main; it is not an engineered detail.

2. Nada / supplier / Alyssa — current Oriel shop box and support
Oriel remains preferred pending viability. Reconcile 72 x 72 in programme,20 in email projection plus 5.5 in jamb, SIDE31.5/CENTER63 quote modules, actual frame/trim envelope, support, operable returns and adjacentW108. Current exact profile is inferred. Option Cis an independent fallback; do not change the Rumford without a separate decision.

3. Alyssa / Matt / Nada — revised tagged window/order and installation section
The marked sketch resolves 589 mm horizontal bank gap and 63.5 mm vertical frame separation; those questions are not still unknown. Need current tagged shop/set-out/RSO/sill/head/frame-glass profiles, separator/support/shear-stud detail, W007 addition and proposed Harper window. Retain two 60 x 28.875 in TW106/TW107 units; extra 60 x 30 line was removed. E101 width 131.75 in is explicit, retained 96.5 in head is not final. E00444 in ICF/39 in framed/38 in frame widths are distinct; blockout height/bucks/anchorage remain open.

4. Nada / Meghan / Alyssa — primary bathroom finish registration and basement lining chain
Later I104149.5 x 138 in room ends 0.12 in inside the earlier south partition face when its north finish is registered. Confirm final finish/backing or source adjustment without rescaling fixtures. Separately resolve mechanical 15 in printed composite versus 13.25 in F2 plus 2 in B1=15.25 in; preserve each layer and its source.

5. Meghan / millworker / installers — actual product and occupied operation checks
Finish full-size cabinet/door/runner/lever/user sweeps and loaded supports for five espresso/alcohol states, all three large trays,15 juleps/two buckets and collector book; maintain beautiful closed coffee cover. Final appliances/plumbing, gas stove/fire clearances, bunk deployment, simulator swing, stairs/guard/channel and glass partition attachment remain to coordinate. Do not replace nominal envelopes with fabricated fit.

6. Project team — property/common datum
Use the current November 13 curated exterior brief and GEEKOMworking source. Establish a common building/property transform and measured thresholds/ground/root/landing levels. Historical designed route profiles and internal numeric fits do not establish surveyed ground, permissions or construction-ready access.
Current release status JSON
{
  "status": "measurement gate held",
  "model_revision": "v18",
  "models": [
    {
      "id": "alcohol",
      "title": "Current working correction · alcohol · measurement hold",
      "file": "room_review/decisions/room-reconciliation-20261115-r26-v18/model-alcohol.027b37142079ffdc363c.json",
      "sha256": "027b37142079ffdc363cba8cbc0ddc4c63005ed2eb46f80030a8f76d2ee8f373",
      "viewer": "room_review/decisions/room-reconciliation-20261115-r26-v18/3d-alcohol.html",
      "rooms": 23,
      "floors": [
        "main",
        "basement"
      ],
      "scope": "Full v18 candidate; larger upholstered chair/floated loveseat and default alcohol bar retained. Complete source/detail/operations gate held; no new images."
    },
    {
      "id": "espresso",
      "title": "Current working correction · espresso · measurement hold",
      "file": "room_review/decisions/room-reconciliation-20261115-r26-v18/model-espresso.dc6653684f05404ad111.json",
      "sha256": "dc6653684f05404ad1113e1f42a7a59a5fb46275aa476a141c77147cce86f533",
      "viewer": "room_review/decisions/room-reconciliation-20261115-r26-v18/3d-espresso.html",
      "rooms": 23,
      "floors": [
        "main",
        "basement"
      ],
      "scope": "Full v18 candidate; larger upholstered chair/floated loveseat and default alcohol bar retained. Complete source/detail/operations gate held; no new images."
    },
    {
      "id": "espresso-open",
      "title": "Current working correction · espresso-open · measurement hold",
      "file": "room_review/decisions/room-reconciliation-20261115-r26-v18/model-espresso-open.1f5b9922e9211298f11e.json",
      "sha256": "1f5b9922e9211298f11e10e98cbef5798ca48292a143497ea00abf746c03ed20",
      "viewer": "room_review/decisions/room-reconciliation-20261115-r26-v18/3d-espresso-open.html",
      "rooms": 23,
      "floors": [
        "main",
        "basement"
      ],
      "scope": "Full v18 candidate; larger upholstered chair/floated loveseat and default alcohol bar retained. Complete source/detail/operations gate held; no new images."
    },
    {
      "id": "alcohol-open",
      "title": "Current working correction · alcohol-open · measurement hold",
      "file": "room_review/decisions/room-reconciliation-20261115-r26-v18/model-alcohol-open.508342117f4cba7b8262.json",
      "sha256": "508342117f4cba7b8262a8ef4f5179bdd69d4e961b09a0f39f3b1600b19b4a16",
      "viewer": "room_review/decisions/room-reconciliation-20261115-r26-v18/3d-alcohol-open.html",
      "rooms": 23,
      "floors": [
        "main",
        "basement"
      ],
      "scope": "Full v18 candidate; larger upholstered chair/floated loveseat and default alcohol bar retained. Complete source/detail/operations gate held; no new images."
    },
    {
      "id": "espresso-operating",
      "title": "Current working correction · espresso-operating · measurement hold",
      "file": "room_review/decisions/room-reconciliation-20261115-r26-v18/model-espresso-operating.d920df685aad1a33557f.json",
      "sha256": "d920df685aad1a33557f45e62683c2b5bda9f83d1bd287d92683e86f6944a207",
      "viewer": "room_review/decisions/room-reconciliation-20261115-r26-v18/3d-espresso-operating.html",
      "rooms": 23,
      "floors": [
        "main",
        "basement"
      ],
      "scope": "Full v18 candidate; larger upholstered chair/floated loveseat and default alcohol bar retained. Complete source/detail/operations gate held; no new images."
    }
  ],
  "rooms": 23,
  "states": 5,
  "new_design_images": 0,
  "checks_per_state": {
    "nominal_frame_envelopes_pass": 35,
    "actual_glazing_apertures_pass": 38,
    "product_instances_pass": 14,
    "typed_room_chains_pass": 11,
    "reported_defect_critical_controls_pass": 41
  },
  "sampling": {
    "frames": 460,
    "controls": 494,
    "scope": "23room scopes x5states xT1/T2/T3/T9; all held. Incomplete inventories/required unknowns prevent whole-room claims. Original W104source false failure and same-draw corrected observer receipts preserved."
  },
  "actual_remaining_boundary_failure": [
    {
      "id": "main.bed1-south-partition.normal-min",
      "wall": "bed1-south-partition",
      "level": "main",
      "quantity": "normal-min",
      "expected_inches": 332.46999999999997,
      "observed_inches": 332.35,
      "delta_inches": -0.1199999999999477,
      "status": "fail",
      "tolerance_inches": 0.0625,
      "tolerance_basis": "Nominal programme/source stroke and retained0.035in cosmetic skin; not field or construction tolerance.",
      "probe": {
        "axis": 1,
        "along_inches": 47.39999999999999,
        "height_inches": 145,
        "selection_rule": "Predeclared fraction/height order excluding source-defined openings and buried closed-junction faces, solely from the2Dprogramme; no observation-dependent swap.",
        "source_exclusions": [
          {
            "along_inches": 28.659999999999986,
            "reason": "The nominal finish probe is buried inside a different source-defined wall at a closed junction; this is not an exposed face.",
            "source_intersecting_walls": [
              "bed-east"
            ]
          }
        ]
      },
      "actual_planes_inches": [
        332.35,
        332.47,
        338.97
      ],
      "actual_face_ids_by_plane": {
        "332.47": [
          "house-face-367"
        ],
        "338.97": [
          "house-face-369"
        ],
        "332.35": [
          "bathroom-r28::nov03-2"
        ]
      },
      "source_basis": "Typed full finished-assembly envelope from source-plan-v2; original core trace retained separately. Source-class/assignment and whole-space QA remain held."
    },
    {
      "id": "main.bed1-south-partition.nominal-envelope-thickness",
      "wall": "bed1-south-partition",
      "level": "main",
      "quantity": "nominal-envelope-thickness",
      "expected_inches": 6.5,
      "observed_inches": 6.6200000000000045,
      "delta_inches": 0.12000000000000455,
      "status": "fail",
      "tolerance_inches": 0.0625,
      "tolerance_basis": "Nominal programme/source stroke and retained0.035in cosmetic skin; not field or construction tolerance.",
      "probe": {
        "axis": 1,
        "along_inches": 47.39999999999999,
        "height_inches": 145,
        "selection_rule": "Predeclared fraction/height order excluding source-defined openings and buried closed-junction faces, solely from the2Dprogramme; no observation-dependent swap.",
        "source_exclusions": [
          {
            "along_inches": 28.659999999999986,
            "reason": "The nominal finish probe is buried inside a different source-defined wall at a closed junction; this is not an exposed face.",
            "source_intersecting_walls": [
              "bed-east"
            ]
          }
        ]
      },
      "actual_planes_inches": [
        332.35,
        332.47,
        338.97
      ],
      "actual_face_ids_by_plane": {
        "332.47": [
          "house-face-367"
        ],
        "338.97": [
          "house-face-369"
        ],
        "332.35": [
          "bathroom-r28::nov03-2"
        ]
      },
      "source_basis": "Typed full finished-assembly envelope from source-plan-v2; original core trace retained separately. Source-class/assignment and whole-space QA remain held."
    }
  ],
  "remaining_draft_questions": "draft-questions.txt",
  "source_profile_and_operations_qualified": false,
  "owner_approval": null
}

Full room register · Actual wall/frame observations · Aperture/contact/stair checks · Actual product envelopes and furniture gaps · Typed room chains · Critical controls and rejection fixtures · All original sampling dispositions · Corrected W104 source observer · Current canonical plan JSON

Property context: Current curated exterior team package. GEEKOM remains the authoritative working writer. No surveyed common datum, terrain, root or permission qualification is implied.