1 · Compare one decision at a time
Loading checked comparison…
Great Room, kitchen and entry context
Light, materials and cameras are common controls. Forest / lake reflections in photographic concepts are illustrative, not a surveyed landscape. Native evidence and source sheets remain available to check geometry.
2 · Combine the window and fireplace in the full model
Try the nine window/fireplace combinations in 3D. The extra single-pane 80-inch control has no gas unit. Combined alternatives have not all received photographic finishing; the image comparisons above deliberately isolate the variables.
Open full-size 2D plan · Open full-size window section
Keep your place
Saved on this browser only. No final preference or owner approval is recorded.
3 · Options, cost basis and decisions still needed
Meghan’s September 22 cozy-nook presentation informs the warm appearance. The source drawings and later owner corrections govern geometry. Existing furniture and both bookcases are retained; no new chair, bar or freestanding bench has been invented.
| Window | Exact study envelope | Benefits / trade-offs | Actual CAD cost basis |
|---|---|---|---|
| Large single Oriel · Chris preference | 94⅝ × 90 in; sill 24 in; projection 28 in | Uninterrupted view; current large envelope retained. Fixed operation is an assumption. Large glass, support and neighbouring ventilation need supplier review. | Unquoted. Do not transfer the casement assembly’s price. |
| Quoted fixed centre + two casements | 94⅝ × 80 in; 14 + 66⅝ + 14 in modules; sill 24 in | Operable side units and a documented quote. Two mullions and a head 10 in lower. Withdrawn as Chris’s preference; retained as an alternative. | $4,336.57 + $563.75 HST = $4,900.32 Quote 2607-AD-0001, modified October 23. Window assembly supply only. Quote depth 0 does not price the projecting box, structure or installation. |
| Historical flat casement | 71½ × 72 in supplier unit; architectural nominal width 72 in; no projection | Smaller, flat opening and no projecting seat. A baseline, not a new supplier proposal. The removed W108 is not reinstated through the current bookcase/art wall. | Historical September 11 line: $2,274.55 before tax; not a current installed price. |
| Single pane at quoted height · control | 94⅝ × 80 in; sill 24 in; projection 28 in | Shows the effect of removing mullions while holding height fixed. Not a quoted configuration. | Unquoted. |
Small gas · separate from the Great Room fireplace
| Option | Visible study geometry | Why compare it / technical limit | Cost |
|---|---|---|---|
| No nook gas | Continuous masonry face | Simplest nook; avoids a second heat source beside an occupied window seat. Existing Great Room Rumford is retained. | No new gas-appliance scope priced; no fabricated saving. |
| Compact flat-front gas | 34⅛ × 20¹⁵⁄₁₆ in viewing area; visible sill proposed at 18 in | Quiet presence in the masonry. Enclave 34 is an appearance/dimension reference, not a selected appliance or certified fit. | Unquoted; appliance, venting, chase, gas and installation scope needed. |
| Compact projecting / three-sided gas | Same front view; proposed 8 in projection toward the nook | Side visibility from the seat, with more enclosure and heat-clearance demands. Projection is a study assumption. | Unquoted; not interchangeable with a previously discussed model’s estimate. |
Marquis Enclave · Enclave 34 manufacturer manual. Actual product and installation pages are included below.
Before a gas choice: the reference body is 34⁵⁄₁₆ × 37⅝ × 16⁷⁄₁₆ in. A visible opening does not prove the body, vent or back-to-back chase fits beside the Rumford. The manual calls for a sealed chase, top discharge and furniture clearances; its 24,000 / 19,000 BTU propane range also needs a comfort assessment for this small nook. No hot-fire seated-use claim is made.
Specific technical questions to resolve
- Supplier acceptance, glass specification, support, attachments, insulation and water management for a single 94⅝-inch pane in a 28-inch projection.
- Large 90-inch unit versus quoted 80-inch unit: framing, head and roof interface require coordinated shop details. Both current upper TW107 units remain; no upper-window removal is selected implicitly.
- The projected seat is the unchanged R26 object. Its cushion top is 27.01 inches above the floor in this working model; final seat height, insulation and comfort remain to be detailed.
- The gas south jamb is held at Y374.64 inches. Its wider product view extends north; the 0.46-inch trim-to-corridor separation is geometric evidence only, not an approved clearance or circulation finding.
- Confirm the gas chassis/mounting datum, side-glass envelope, 36-inch front / 8½-inch side furniture clearances, occupied-seat comfort and vent route beside the wood-burning chase.
- The provisional top grille opening is 31⅜ × 3¼ inches at Z251.75–255. The ceiling is Z256.125. Sealed-enclosure top alignment and the larger grille trim are unresolved; the model is not an installation detail.
- The quote lists a white screen on one casement and black on the other. Confirm intended screen/finish specification if that alternative returns.
4 · Find the change on the actual source sheets
Twenty-three primary pages were supplied together to the real CLI source-review worker. Latest A102 / A200 / A201, roof, section and details are included alongside the older 90-inch elevation, quoted assembly, final-order context and product sheets. Later owner direction keeps the masonry flat and removes visible supports, even where the preserved architectural sheets still show a bay/support detail.
5 · Source, 2D, 3D, native and photographic evidence
Every rejected preparation, camera probe and photographic attempt is retained with its correction. Study checks do not certify construction, structural feasibility, product suitability or an owner gate.
All released plans, sections, native and photographic frames
























Earlier R26 nook location study · Return to whole-house viewer