  "parent": {
    "file": "house/2026-11-07-primary-ensuite-r28/model3d.json",
    "sha256": "0a6e9f338bfcab7c0a90ede51208dc3c4e2a878d51075442363d77d583a34b0a"
  },
  "rows": [
    {
      "tag": "W101",
      "room": "Bedroom2 · Michelle",
      "architectural_baseline": "Permit102x80, sill16; Oct6 elevation102x96, sill0",
      "final_order": "99x96;74fixed +25operator over25x24fixed",
      "current_model": "R28plan/mesh102x96. Divider at2/3 gives68+34, not74+25. Floor-height direction is applied.",
      "action": "Use99-inch supplier frame in a new version; replace divider with74/25 and correct outside-view handing. Obtain assembly rough opening; retain location until jamb alignment is confirmed.",
      "decision": "Change required:3in narrower than Oct6/model. This is a source reconciliation, not evidence of a changed room wall.",
      "order_pages": [
        8
      ],
      "status": "change",
      "owner_approval": null
    },
    {
      "tag": "W102",
      "room": "Bedroom2 · Michelle",
      "architectural_baseline": "Permit102x80, sill16; Oct6 elevation102x96, sill0",
      "final_order": "99x96;74fixed +25operator over25x24fixed",
      "current_model": "R28plan/mesh102x96. Divider at2/3 gives68+34, not74+25. Floor-height direction is applied.",
      "action": "Use99-inch supplier frame in a new version; replace divider with74/25 and correct outside-view handing. Obtain assembly rough opening; retain location until jamb alignment is confirmed.",
      "decision": "Change required:3in narrower than Oct6/model. This is a source reconciliation, not evidence of a changed room wall.",
      "order_pages": [
        7
      ],
      "status": "change",
      "owner_approval": null
    },
    {
      "tag": "W103",
      "room": "Primary bathroom WC",
      "architectural_baseline": "25x48, sill48, head96",
      "final_order": "25x60, left casement; rough26x61",
      "current_model": "R28and Nov3 standalone:25x48 at48 sill",
      "action": "Increase height12in. If head96 is retained, sill becomes36in; this is an inferred placement requiring designer confirmation against WC/privacy and current I104.",
      "decision": "Order change not yet incorporated in either bathroom model.",
      "order_pages": [
        7
      ],
      "status": "change",
      "owner_approval": null
    },
    {
      "tag": "W104",
      "room": "Primary bathroom tub",
      "architectural_baseline": "72x90, sill6, head96",
      "final_order": "72x96 atfloor; fixed70in above26in slider",
      "current_model": "R28and Nov3 standalone72x90 at6sill; rail30abovefloor",
      "action": "Lower sill6in tofloor; move rail from30to26in, upper fixed70in. Check bath/window adjacency and privacy without changing74in vanity or removed tower. Assembly rough opening remains absent.",
      "decision": "Change required. Retain all unrelated November3 interior layout.",
      "order_pages": [
        6,
        7
      ],
      "status": "change",
      "owner_approval": null
    },
    {
      "tag": "W109",
      "room": "Great Room side/exterior",
      "architectural_baseline": "Permit24x72/sill24",
      "final_order": "27x72 right casement; rough28x73",
      "current_model": "Actual R28glass24x72 at24sill",
      "action": "Widen nominal unit3in; retain sill/head pending rough-opening/location coordination; verify jamb and adjacent siding.",
      "decision": "Change required; current Great Room detailed source and derived room also24wide.",
      "order_pages": [
        2
      ],
      "status": "change",
      "owner_approval": null
    },
    {
      "tag": "W110",
      "room": "Boot room",
      "architectural_baseline": "24x36/sill60/head96",
      "final_order": "25x54; rough26x55",
      "current_model": "R28plan/mesh24x36/sill60",
      "action": "Widen1in and raise height18in. Keeping head96 implies sill42in, which matches kitchen alignment; confirm head datum and cabinetry.",
      "decision": "Change not applied. Email match-to-W112 direction supports head96/sill42 inference.",
      "order_pages": [
        1
      ],
      "status": "change",
      "owner_approval": null
    },
    {
      "tag": "W111",
      "room": "Powder room",
      "architectural_baseline": "48x36/sill60/head96",
      "final_order": "25x54; rough26x55",
      "current_model": "R28plan/mesh48x36/sill60",
      "action": "Narrow23in; increase height18in. Keeping head96 implies sill42in. Confirm outside corner reveal/jamb anchor instead of assuming centred placement.",
      "decision": "Change not applied; significant south-elevation appearance difference.",
      "order_pages": [
        1
      ],
      "status": "change",
      "owner_approval": null
    },
    {
      "tag": "W003",
      "room": "Bedroom3 · lake",
      "architectural_baseline": "144x80/sill16",
      "final_order": "138.9375x80;36/66.6875/36 plus couplers",
      "current_model": "R28plan/mesh144x80;24/96/24 nominal module ratios",
      "action": "Narrow5.0625in and use actual36in flankers. Overall139-frame-class unit is0.25in narrower than E100139.1875 above: obtain intentional jamb/mullion datum.",
      "decision": "Required change with alignment clarification; do not force glass/frame/rough jambs into equality.",
      "order_pages": [
        9,
        10
      ],
      "status": "change",
      "owner_approval": null
    },
    {
      "tag": "W004",
      "room": "Rec room · lake",
      "architectural_baseline": "144x80/sill16",
      "final_order": "145.125x80;36/72.875/36 plus couplers",
      "current_model": "R28plan/mesh144x80;24/96/24 divisions",
      "action": "Widen1.125in; use36in flankers and actual couplers. Supplier must confirm36x80 casement limits; align to145.122in CW1frame above using physical frame/rough datums.",
      "decision": "Change required. Overall upper/lower frame widths differ only0.003in using the detailed3686.1mm dimension (0.007in using rounded3686mm); this is rounding, not a real alignment defect.",
      "order_pages": [
        10,
        11
      ],
      "status": "change",
      "owner_approval": null
    },
    {
      "tag": "W005",
      "room": "Rec room · lake",
      "architectural_baseline": "144x80/sill16",
      "final_order": "145.125x80;36/72.875/36 plus couplers",
      "current_model": "R28plan/mesh144x80;24/96/24 divisions",
      "action": "Widen1.125in; use36in flankers and actual couplers. Supplier must confirm36x80 casement limits; align to145.122in CW1frame above using physical frame/rough datums.",
      "decision": "Change required. Overall upper/lower frame widths differ only0.003in using the detailed3686.1mm dimension (0.007in using rounded3686mm); this is rounding, not a real alignment defect.",
      "order_pages": [
        10,
        11
      ],
      "status": "change",
      "owner_approval": null
    },
    {
      "tag": "W006",
      "room": "Rec room · west",
      "architectural_baseline": "24x72/sill24/head96",
      "final_order": "27x80 right casement; rough28x81",
      "current_model": "R28plan/mesh24x72",
      "action": "Widen3in and increase height8in. Preserving head96 gives16in sill; order itself does not state mounting height. Confirm sill, egress and deck/ground relation.",
      "decision": "Change required; do not silently keep24in sill and raise head to104in.",
      "order_pages": [
        13
      ],
      "status": "change",
      "owner_approval": null
    },
    {
      "tag": "CW1 lower · SB001/SB002",
      "room": "Great Room lake",
      "architectural_baseline": "A200/A300 traced six-pane lower bank; structural station governs",
      "final_order": "Two3686x2438mm three-panel banks; about145.118x95.984in",
      "current_model": "R28six glass faces each108in high, from1.92to109.92abovefloor; two banks about145inwide",
      "action": "Reconcile the12in lower-height difference as an assembly: finished floor/sill, frame/glass, intermediate steel/mullions and upper geometry. Do not lower/raise roof or beams from this comparison alone.",
      "decision": "Current window wall is not a certified match to final order. Glass already exceeds supplier whole-frame height, so frame allowances cannot explain12in.",
      "order_pages": [
        3
      ],
      "status": "coordination",
      "owner_approval": null
    },
    {
      "tag": "CW1 upper · SB100/SB101",
      "room": "Great Room lake",
      "architectural_baseline": "A200/A3001:12 roof stations; current model follows sloped upper openings",
      "final_order": "3686mm banks; high/low corners1752.6/1445.4mm and1393.8/1086.6mm",
      "current_model": "R28upper glass heights west53.56/49.533/45.5in, east39.513/35.487/31.46in; common base115.92abovefloor",
      "action": "Obtain a tagged shop elevation placing each bank on the section datum. Detailed dimensions give1:12 fall; assembly labels4.5/12 and5.7/12 contradict that. Verify SB100/101 bank orientation and supports.",
      "decision": "Coordinate, not automatic roof redesign. Per-frame declared slope1/12 agrees with detailed corner differences.",
      "order_pages": [
        3,
        4
      ],
      "status": "coordination",
      "owner_approval": null
    },
    {
      "tag": "E100",
      "room": "Bedroom1 patio slider",
      "architectural_baseline": "139x96 nominal; current traced aperture140.375",
      "final_order": "139.1875x95.5 frame; rough140.1875x96; XOX",
      "current_model": "R28aperture140.375x96; study nominal139; equal third divisions",
      "action": "Use actual frame and unequal upper widths; rough width difference0.1875in is within old0.67in tracing uncertainty, not evidence framing is wrong. Actual field rough opening still required.",
      "decision": "XOX operation was already owner direction; frame size/upper alignment detail requires update.",
      "order_pages": [
        5
      ],
      "status": "change",
      "owner_approval": null
    },
    {
      "tag": "TW100–TW102",
      "room": "Bedroom1 above slider",
      "architectural_baseline": "Each45.5wide; high edges20.375/24.125/27.875; sill103",
      "final_order": "Overall139.1875wide;47.3125/44.5625/47.3125; high edges24.25/27.9375/31.875",
      "current_model": "R28three45.5wide panes, old high edges20.375/24.125/27.875; head1:12",
      "action": "Replace widths and sloped heights while keeping roof and structural positions until vertical placement verified. Align to actual E100panel/mullion locations. Do not assume sill103 still works.",
      "decision": "Change required. Relative shape taller by roughly4in; supplier assembly sill/head elevations absent.",
      "order_pages": [
        5
      ],
      "status": "change",
      "owner_approval": null
    },
    {
      "tag": "TW103–TW105",
      "room": "Kitchen/entry high south clerestory",
      "architectural_baseline": "45.5each; high edges20.25/24.125/27.875; sill144",
      "final_order": "45.5each; high edges21.375/25.125/28.875",
      "current_model": "No explicit tagged opening records in R28plan; actual geometric candidates must be traced by location",
      "action": "Add tag bindings; compare candidate south clerestory geometry to current1:12 sections. Nominal tallest-height increase1in (TW103+1.125in) versus schedule. Confirm mounting datum.",
      "decision": "Cannot certify as present/correct solely from source-plan metadata. Needs explicit face-to-tag mapping.",
      "order_pages": [
        11,
        12
      ],
      "status": "coordination",
      "owner_approval": null
    },
    {
      "tag": "TW106/TW107",
      "room": "Great Room high side glazing",
      "architectural_baseline": "60x24 each, sill144",
      "final_order": "Item25qty2 at60x28.875; item26qty1 labelledTW107at60x30",
      "current_model": "R28has two explicit60x24 faces at144sill",
      "action": "Supplier must resolve duplicateTW107tag/extra unit and intended locations before changing heights. Retain two openings pending answer.",
      "decision": "Order has3units for2known tags. Cannot pick28.875or30in forTW107without confirmation.",
      "order_pages": [
        12
      ],
      "status": "coordination",
      "owner_approval": null
    },
    {
      "tag": "E002",
      "room": "Basement lake walkout",
      "architectural_baseline": "71.5x95.5",
      "final_order": "70.625x95.5 frame; rough71.625x96; XO",
      "current_model": "R28aperture71.5x95.5; no shopframe distinction",
      "action": "Model actual frame/roughopening separately.0.125in width difference between modelaperture andrough is belowtraceuncertainty; no claim of wrong concrete opening.",
      "decision": "Small frame/rough-vs-nominal distinction, not0.875in proven construction shortfall.",
      "order_pages": [
        11
      ],
      "status": "change",
      "owner_approval": null
    },
    {
      "tag": "E004",
      "room": "Basement west entry",
      "architectural_baseline": "36x95.5 nominal door",
      "final_order": "38x95.5 overallframe;39x96 normalrough; email44in ICFrough",
      "current_model": "R28generic36wide glazing/opening",
      "action": "Represent36slab/38frame/39rough/44ICFblockout as distinct datums. Obtain buck thickness, tolerances and anchoring detail; never enlarge36slab to44.",
      "decision": "Email/attachment dimensions need buck-detail reconciliation, not a blind5in framing error conclusion.",
      "order_pages": [
        13
      ],
      "status": "coordination",
      "owner_approval": null
    }
  ],
  "applied": false,
  "approval": null
}