  "status": "needs-spatial-correction",
  "native_frame_findings": [
    "Great Room pairs 17/20 and 18/21 show SB104 and SB103 changing consistently from black to rust. Timber, glazing, masonry, furniture and lighting appear unchanged; framing and perspective agree visually.",
    "Entry-porch pair 16/19 does not demonstrate the required finish change. The header above the entry remains dark in both images, with no clearly identifiable rust SB105. Adding its numeric faces has not established its visible exposure or correct material assignment in the rendered scene.",
    "C103 is concealed behind the transom-wall plaster in both junction images. This supports class B; the junction camera does not prove an exposed post finish.",
    "SB104 now visibly reads at full depth from the Great Room. The wood ceiling and recessed clerestory openings are visible, resolving the principal v1 presentation defects."
  ],
  "inventory_findings": [
    "A: SB103, proposed exposed SB104, porch SB105 and provisional metal stair spindles. S102 explicitly calls SB103 and SB105 exposed/powder coated; SB104 exposure remains an owner-requested study condition.",
    "B: C103 and the listed wall-, pier-, floor- and roof-enclosed members are reasonably classified as concealed. The earlier requirement to expose C103 is superseded by this enclosure evidence.",
    "C: Connection inventory identifies the principal S102/S301 connections, but SB104 stiffeners beneath C103 would be visible in the newly exposed web recess and remain absent. Their required presence is established even though final fabrication details remain unresolved.",
    "Timber nailers/packouts need a separate non-steel coordination entry. Exterior architectural guards cannot be classified as non-architectural merely because these cameras exclude them; identify them as architectural steel outside this study's camera scope.",
    "No additional explicitly exposed Great Room scheduled beam beyond SB103 is identified in the supplied structural crop. SB105 is the source-required exposed porch member omitted from original R30."
  ],
  "numeric_findings": [
    "SB104: length 344.080 versus 343.875in, difference +0.205in; depth 18.000 versus 18.100in, difference -0.100in. Top Z269.500 minus floor Z138 equals the scheduled 131.500in. Centreline Y273.760.",
    "SB103: length 228.320 versus 230.750in, difference -2.430in; depth 10.000 versus 10.330in, difference -0.330in. Top Z296.500 minus floor Z138 equals the scheduled 158.500in. Centreline X544.720.",
    "C103: 5\u00d75in section centred X544.720/Y273.760 aligns internally with both beams. Model height 17.000 versus scheduled plate-inclusive 16.625in, difference +0.375in; plates are not separately represented.",
    "SB105: length 120.120 versus 120.125in, difference -0.005in; top Z248.500 gives the scheduled 110.500in above floor. Its approximately 3.6in source-registration difference and inferred soffit infill remain unverified placement details.",
    "Lake pier width is 23.520in. SB103 is centred within it and penetrates 1.200in beyond its interior face, consistent with a buried end rather than a demonstrated exposed clash.",
    "TW103\u2013105 now each have four reveals spanning Y270.480\u2013278.480, closing the previous 8in depth omission. The raised roof underside is approximately 0.13833in above the registered wood ceiling, resolving the previous reversed layering."
  ],
  "required_spatial_corrections": [
    "Resolve the porch render discrepancy: demonstrate SB105's exposed faces in both options, remove any unintended enclosure or correct material assignment, and renew the same-camera black/rust native pair before finishing.",
    "Represent the source-required visible SB104 web stiffeners with clearly labelled provisional geometry, or provide source-supported evidence that the finished assembly conceals them. Apply the same option finish to all exposed connection surfaces.",
    "Reconcile SB103 endpoints and C103's plate-inclusive assembly against source datums before claiming dimensional agreement. Hidden ends do not establish a bearing allowance; retain unresolved differences explicitly in any bounded appearance study."
  ],
  "qualifications": [
    "The visible Great Room corrections pass this scoped review; the porch finish/exposure failure prevents release of the complete all-exposed-steel comparison.",
    "The declared 876 finish-assigned faces reconcile as 18 SB104 + 18 SB103 + 18 SB105 + 6 concealed C103 + 816 stair faces. Complete paired option records were not supplied, so whole-model finish-only equivalence remains asserted rather than independently verified. Native pairs support visual equivalence only within their views.",
    "Paired camera hashes differ, although declared poses and projected anchors agree. Anchor roundtrip checks establish projection consistency, not visibility, complete scene equality or final-pixel fidelity.",
    "The supplied order page does not independently establish all TW103\u2013105 dimensions. Reveal closure is verified separately from supplier-order correctness.",
    "Exact source-to-model positional offsets for SB104/SB103/C103 remain uncertified without registered drawing witnesses. Connection fabrication, nailers, fire protection and coating systems remain engineering/shop coordination items.",
    "Black and rust/patina remain equally preferred study options. Michelle's decision and owner geometry approvals are not inferred; rust appearance must retain the specified coating-system qualification."
  ]
}