  "status": "needs-spatial-correction",
  "inventory_findings": [
    "Inventory is incomplete: S102 explicitly labels the kitchen/entry-side header SB105 W12x14 as EXPOSED STEEL BEAM\u2014BEAM TO BE POWDER COATED. Its B/concealed classification is incorrect. R30 must represent its exposed finished-room surfaces and include them in both finish options.",
    "SB104, SB103 and C103 correctly belong in A as intended exposed steel, but their actual visibility is compromised by the modelled enclosure described below.",
    "S301 plates, stiffeners, bolts and shear connections belong in C pending connection-specific coordination. Timber nailers/packouts need a separate non-steel entry; their presence can affect steel exposure.",
    "Window products, appliances, furniture hardware and luminaires can remain D. Exterior architectural steel guards are outside these interior cameras, rather than inherently non-architectural metal. Stair spindles remain an explicitly provisional A representation."
  ],
  "numeric_findings": [
    "SB104: model length 344.080in versus scheduled 343.875in: +0.205in. Model depth 18.000in versus supplied section depth 18.100in: \u22120.100in. Top Z269.500 minus floor Z138 equals 131.500in, matching the scheduled top. Model centreline Y273.760.",
    "SB103: model length 228.320in versus scheduled 230.750in: \u22122.430in. Calling this a match 'within bearing allowances' is unsupported. Model depth 10.000in versus supplied 10.330in: \u22120.330in. Top Z296.500 minus floor Z138 equals 158.500in, matching the scheduled top. Model centreline X544.720.",
    "C103: model section is 5.000\u00d75.000in, centred at X544.720/Y273.760 and aligned with both beams. Its 17.000in model height exceeds the scheduled 16.625in plate-inclusive length by 0.375in. The solid model post occupies the entire flange-to-flange gap, leaving no separately represented plate thickness.",
    "Actual lake pier width is 556.480\u2212532.960=23.520in, rather than the inventory's 23.400in. SB103 is centred within it and extends 1.200in beyond its interior face Y500.880.",
    "The R2 plaster roof underside is consistently 0.11167in below the wood ceiling plane: at X409.040, Z312.00833 versus Z312.12000. This is overlapping presentation geometry, not a finish-only distinction."
  ],
  "required_spatial_corrections": [
    "Restore the source-required exposed SB105 representation and amend the inventory before comparing all-exposed-steel finishes.",
    "Resolve SB104/C103 concealment at the south clerestory wall. SB104 ends at Y277.520, while opaque interior wall triangles lie at Y278.480 and begin at Z256.125, screening most of its upper depth from the room. At C103 X542.220\u2013547.220, the same solid wall covers the post's Z269.500\u2013286.500 range. This is a concrete enclosure conflict, not merely an unknown bolt detail.",
    "Complete the south clerestory opening enclosure: TW103\u2013105 frames/glass lie at Y270.480, but the interior wall skin is at Y278.480. The supplied complete local faces contain no jamb, sill or head reveals bridging this 8.000in wall depth. Preserve the ordered openings while closing these exposed wall edges.",
    "Remove or correctly partition the competing R2 underside/finished-ceiling surfaces. The lower opaque roof underside can hide the wood ceiling and produce inconsistent wall-to-ceiling junctions, including at the lake pier.",
    "Reconcile the SB103 length and C103 plate-inclusive assembly against their source datums; retain them as discrepancies until resolved rather than assigning passing statuses. Apply any resulting common geometry correction identically to both options, then renew native review."
  ],
  "qualifications": [
    "The supplied option declarations describe finish-only changes to 858 faces: 18 SB104 + 18 SB103 + 6 C103 + 816 stair faces; 51,150 other faces remain unchanged. This is internally consistent, but complete paired option face records were not supplied for an independent whole-model byte comparison. Different model hashes alone do not prove finish-only equivalence.",
    "The supplied upper-window order image shows item 25/26 and only the preceding trapezoid entry's tail; it does not independently verify all TW103\u2013105 ordered dimensions. Their being unchanged between options does not establish source correctness.",
    "Member axes are internally aligned, but exact source-to-model position offsets cannot be certified from these full-sheet raster images without registered dimension witnesses. No unsupported zero-offset positional pass is assigned.",
    "Final bearing lengths, connection selection, plates, stiffeners, packouts, fire protection and coating specifications remain engineering/shop coordination items. They do not excuse the demonstrated enclosure and missing-exposure defects.",
    "Black and rust/patina retain equal preference. Michelle's final decision and all owner geometry approvals remain pending; photographic finishing should wait for correction and renewed review."
  ]
}