 "date": "2026-11-10",
 "revision": "v4",
 "model_sha256": "efb113b01685fded1325857a490f1d8968d9f485ee2dc76001d60c378ad0fcf4",
 "canonical_r30_sha256": "bbd4f45db85c99afc82cb073210fc2ca0b602e7964d244eedc96fddf9a81d6ac",
 "common_corrections": {
  "date": "2026-11-10",
  "parent_model_sha256": "bbd4f45db85c99afc82cb073210fc2ca0b602e7964d244eedc96fddf9a81d6ac",
  "removed": [
   "house-face-17216",
   "house-face-17217",
   "house-face-17229",
   "house-face-17230"
  ],
  "clipped": [
   "ordered-r29-patch-812",
   "ordered-r29-patch-820",
   "ordered-r29-patch-821",
   "ordered-r29-patch-822",
   "ordered-r29-patch-823",
   "ordered-r29-patch-824",
   "ordered-r29-patch-825",
   "ordered-r29-patch-826"
  ],
  "moved": [
   "house-face-23076-penetration-0",
   "house-face-23076-penetration-1",
   "house-face-23076-penetration-2",
   "house-face-23076-penetration-3",
   "house-face-23076-penetration-4",
   "house-face-23076-penetration-5",
   "house-face-23076-penetration-6",
   "house-face-23076-penetration-7"
  ],
  "added": [
   "steel-c1-sb104-lip",
   "steel-c1-sb104-return-east",
   "steel-c1-sb104-return-west",
   "steel-c1-kitchen-ceiling-slot",
   "steel-c1-SB105-bottom-bottom",
   "steel-c1-SB105-bottom-top",
   "steel-c1-SB105-bottom-south",
   "steel-c1-SB105-bottom-north",
   "steel-c1-SB105-bottom-east",
   "steel-c1-SB105-bottom-west",
   "steel-c1-SB105-top-bottom",
   "steel-c1-SB105-top-top",
   "steel-c1-SB105-top-south",
   "steel-c1-SB105-top-north",
   "steel-c1-SB105-top-east",
   "steel-c1-SB105-top-west",
   "steel-c1-SB105-web-bottom",
   "steel-c1-SB105-web-top",
   "steel-c1-SB105-web-south",
   "steel-c1-SB105-web-north",
   "steel-c1-SB105-web-east",
   "steel-c1-SB105-web-west",
   "steel-c1-SB105-infill-bottom",
   "steel-c1-SB105-infill-top",
   "steel-c1-SB105-infill-south",
   "steel-c1-SB105-infill-north",
   "steel-c1-SB105-infill-east",
   "steel-c1-SB105-infill-west",
   "steel-c1-TW103-reveal-0",
   "steel-c1-TW103-reveal-1",
   "steel-c1-TW103-reveal-2",
   "steel-c1-TW103-reveal-3",
   "steel-c1-TW104-reveal-0",
   "steel-c1-TW104-reveal-1",
   "steel-c1-TW104-reveal-2",
   "steel-c1-TW104-reveal-3",
   "steel-c1-TW105-reveal-0",
   "steel-c1-TW105-reveal-1",
   "steel-c1-TW105-reveal-2",
   "steel-c1-TW105-reveal-3"
  ],
  "owner_approval": null,
  "reasons": {
   "SB104": "Owner direction includes the large horizontal beam; R30 wrapped it in a coplanar plaster soffit/closure leaving only a 4.62in strip. S102 shows the transom wall bearing on it; S301 detail 6 nailer. Architect/builder to confirm exposure.",
   "SB105": "S102: EXPOSED STEEL BEAM - BEAM TO BE POWDER COATED; absent from R30. Placement aligned to R30 porch wall faces (S102 trace about 3.6in further south, within registration uncertainty).",
   "reveals": "Independent source review: TW103-105 had no reveals through the 8in wall.",
   "roof_underside": "Great Room roof underside plane was 0.112in below the registered wood ceiling, hiding it."
  },
  "v3_parent_sha256": "cf363203c26fd50060e2355a994f7156784c6788074a042ad9d9327347067572",
  "v3_added_stiffener_faces": [
   "steel-c3-SB104-stiffener-542.314-north-bottom",
   "steel-c3-SB104-stiffener-542.314-north-top",
   "steel-c3-SB104-stiffener-542.314-north-ya",
   "steel-c3-SB104-stiffener-542.314-north-yb",
   "steel-c3-SB104-stiffener-542.314-north-xa",
   "steel-c3-SB104-stiffener-542.314-north-xb",
   "steel-c3-SB104-stiffener-542.314-south-bottom",
   "steel-c3-SB104-stiffener-542.314-south-top",
   "steel-c3-SB104-stiffener-542.314-south-ya",
   "steel-c3-SB104-stiffener-542.314-south-yb",
   "steel-c3-SB104-stiffener-542.314-south-xa",
   "steel-c3-SB104-stiffener-542.314-south-xb",
   "steel-c3-SB104-stiffener-547.126-north-bottom",
   "steel-c3-SB104-stiffener-547.126-north-top",
   "steel-c3-SB104-stiffener-547.126-north-ya",
   "steel-c3-SB104-stiffener-547.126-north-yb",
   "steel-c3-SB104-stiffener-547.126-north-xa",
   "steel-c3-SB104-stiffener-547.126-north-xb",
   "steel-c3-SB104-stiffener-547.126-south-bottom",
   "steel-c3-SB104-stiffener-547.126-south-top",
   "steel-c3-SB104-stiffener-547.126-south-ya",
   "steel-c3-SB104-stiffener-547.126-south-yb",
   "steel-c3-SB104-stiffener-547.126-south-xa",
   "steel-c3-SB104-stiffener-547.126-south-xb"
  ],
  "v3_reason": "Renewed CLI review: S102 requires SB104 web stiffeners below C103; visible in the exposed web recess. Provisional geometry.",
  "v4_parent_sha256": "05855400be60cb375a23ae147dd8a9b35d385ddd61ef4fe66ef4fb81f0eadaa2",
  "v4_removed_face_ids": [
   "steel-c1-SB105-infill-bottom",
   "steel-c1-SB105-infill-top",
   "steel-c1-SB105-infill-south",
   "steel-c1-SB105-infill-north",
   "steel-c1-SB105-infill-east",
   "steel-c1-SB105-infill-west",
   "steel-c3-SB104-stiffener-542.314-north-bottom",
   "steel-c3-SB104-stiffener-542.314-north-top",
   "steel-c3-SB104-stiffener-542.314-north-ya",
   "steel-c3-SB104-stiffener-542.314-north-yb",
   "steel-c3-SB104-stiffener-542.314-north-xa",
   "steel-c3-SB104-stiffener-542.314-north-xb",
   "steel-c3-SB104-stiffener-542.314-south-bottom",
   "steel-c3-SB104-stiffener-542.314-south-top",
   "steel-c3-SB104-stiffener-542.314-south-ya",
   "steel-c3-SB104-stiffener-542.314-south-yb",
   "steel-c3-SB104-stiffener-542.314-south-xa",
   "steel-c3-SB104-stiffener-542.314-south-xb",
   "steel-c3-SB104-stiffener-547.126-north-bottom",
   "steel-c3-SB104-stiffener-547.126-north-top",
   "steel-c3-SB104-stiffener-547.126-north-ya",
   "steel-c3-SB104-stiffener-547.126-north-yb",
   "steel-c3-SB104-stiffener-547.126-north-xa",
   "steel-c3-SB104-stiffener-547.126-north-xb",
   "steel-c3-SB104-stiffener-547.126-south-bottom",
   "steel-c3-SB104-stiffener-547.126-south-top",
   "steel-c3-SB104-stiffener-547.126-south-ya",
   "steel-c3-SB104-stiffener-547.126-south-yb",
   "steel-c3-SB104-stiffener-547.126-south-xa",
   "steel-c3-SB104-stiffener-547.126-south-xb"
  ],
  "v4_added_face_ids": [
   "steel-c4-porch-decorative-timber-0-bottom",
   "steel-c4-porch-decorative-timber-0-top",
   "steel-c4-porch-decorative-timber-0-south",
   "steel-c4-porch-decorative-timber-0-north",
   "steel-c4-porch-decorative-timber-0-east",
   "steel-c4-porch-decorative-timber-0-west",
   "steel-c4-porch-decorative-timber-1-bottom",
   "steel-c4-porch-decorative-timber-1-top",
   "steel-c4-porch-decorative-timber-1-south",
   "steel-c4-porch-decorative-timber-1-north",
   "steel-c4-porch-decorative-timber-1-east",
   "steel-c4-porch-decorative-timber-1-west",
   "steel-c4-greatroom-east-upper-plaster"
  ],
  "v4_reason": "Chris Nov 10 review: remove beam break (web stiffeners) and green stripe; A-200/S103 show decorative timbers, not infill, above SB105."
 },
 "scope": "Both options share this corrected geometry; only the steel finish record differs.",
 "checks": [
  {
   "item": "SB104 depth",
   "source": "W18x55 nominal 18.1in",
   "model": [
    251.5,
    269.5
   ],
   "status": "simplified",
   "note": "Model 18.0in (-0.1in)."
  },
  {
   "item": "SB104 length",
   "source": "S103 cut 28'-7 7/8\" = 343.875in",
   "model": [
    373.36,
    717.44
   ],
   "status": "match",
   "note": "Model 344.08in (+0.205in)."
  },
  {
   "item": "SB104 top of steel",
   "source": "S103 10'-11 1/2\" = 131.5in above main floor",
   "model": [
    251.5,
    269.5
   ],
   "status": "match",
   "note": "Z269.5 - 138 = 131.5in."
  },
  {
   "item": "SB104 exposure",
   "source": "S102 transom wall on SB104; owner direction",
   "model": "Plaster soffit/closure removed; Great Room skin clipped to Z269.5",
   "status": "corrected",
   "note": "Visible full depth X374.32-688.0 (Great Room) and 4.62in below the kitchen ceiling."
  },
  {
   "item": "SB103 depth",
   "source": "W10x26 nominal 10.33in",
   "model": [
    286.5,
    296.5
   ],
   "status": "simplified",
   "note": "Model 10.0in (-0.33in)."
  },
  {
   "item": "SB103 length",
   "source": "S103 cut 19'-2 3/4\" = 230.75in",
   "model": [
    273.76,
    502.08
   ],
   "status": "discrepancy",
   "note": "Model 228.32in (-2.43in); both ends hidden at the wall/pier."
  },
  {
   "item": "SB103 top of steel",
   "source": "S103 13'-2 1/2\" = 158.5in",
   "model": [
    286.5,
    296.5
   ],
   "status": "match",
   "note": "Z296.5 - 138 = 158.5in."
  },
  {
   "item": "SB105 length and level",
   "source": "S103 cut 10'-0 1/8\" = 120.125in; top 9'-2 1/2\" = 110.5in",
   "model": {
    "x": [
     388.49,
     508.61
    ],
    "y": [
     110.3,
     114.27
    ],
    "z": [
     236.6,
     248.5
    ]
   },
   "status": "match",
   "note": "X388.49-508.61 (120.12in); top Z248.5."
  },
  {
   "item": "SB105 north-south placement",
   "source": "S102 trace at porch front",
   "model": [
    110.3,
    114.27
   ],
   "status": "inferred",
   "note": "Aligned to porch wall faces Y110.3; S102 trace about 3.6in further south."
  },
  {
   "item": "C103 position",
   "source": "HSS 5x5 on SB104 under SB103 (S102)",
   "model": {
    "x": [
     542.22,
     547.22
    ],
    "y": [
     271.26,
     276.26
    ],
    "z": [
     269.5,
     286.5
    ]
   },
   "status": "match-concealed",
   "note": "Inside the transom wall."
  },
  {
   "item": "C103 length",
   "source": "Schedule 1'-4 5/8\" incl. plates",
   "model": [
    269.5,
    286.5
   ],
   "status": "unresolved",
   "note": "17.0in gap; 0.375in difference."
  },
  {
   "item": "Lake pier (C100.1)",
   "source": "S102 C100.1 at SB103 lake end",
   "model": "CW-west to X532.96, CW-east from X556.48 (23.52in pier)",
   "status": "match-concealed",
   "note": "SB103 centreline X544.72 inside the pier; extends 1.2in past its interior face Y500.88."
  },
  {
   "item": "Clerestory reveals",
   "source": "8.0in wall (Y270.48-278.48)",
   "model": "Reveals added for TW103-105",
   "status": "corrected",
   "note": "v1 had none."
  },
  {
   "item": "Wood ceiling visibility",
   "source": "Registered wood ceiling R2-main",
   "model": "Roof underside raised 0.25in",
   "status": "corrected",
   "note": "Underside had been 0.112in below the ceiling."
  },
  {
   "item": "SB104 web stiffeners",
   "source": "S102 'provide web stiffeners below' C103",
   "model": "Removed from study (owner direction)",
   "status": "unresolved",
   "note": "Builder/engineer to confirm whether required and how they would appear."
  },
  {
   "item": "SB105 on A-200",
   "source": "A-200 rear elevation: dark band across porch opening below soffit, two timber ends above",
   "model": "SB105 + two decorative timbers",
   "status": "match",
   "note": "Confirms the S102 exposed porch beam; earlier siding photographs used an older model without it."
  },
  {
   "item": "Great Room grey-green band",
   "source": "R30 exterior central-R1 east fascia visible inside",
   "model": "Interior plaster face X374.62",
   "status": "corrected",
   "note": "Owner identified Nov 10."
  },
  {
   "item": "Everything else",
   "source": "R30",
   "model": "Every other face byte-identical to R30; both options identical except steel finish",
   "status": "unchanged",
   "note": "Asserted in build_models_v2.py / build_options_v2.py."
  }
 ]
}