  "revision": "Muskoka-source-assembly-v26-shared-opening-proposal",
  "primary": {
    "file": "docs/Drive_Sync/07_PERMITS/BP-2026-0678 Building Permit (Issued 2026-08-20).pdf",
    "sha256": "ec9f327ed22e13252c42b577145b501c045caa65aa4a13bd8161fa8ed98d706d"
  },
  "primary_context_pages_one_based": [
    84,
    85,
    86,
    87,
    88,
    89,
    94,
    95,
    96,
    98
  ],
  "wall_plane_bounds_world_inches": [
    724.355,
    274.695,
    872.98,
    416.32
  ],
  "nominal_wall_plane_spans_inches": [
    148.625,
    141.625
  ],
  "nominal_infill_envelope_depth_inches": 7.875,
  "west_profile_source_class": "Inferred nominal working profile, visually consistent with A102linework; final weatherwall/screen system unselected.",
  "main_floor_world_inches": 138,
  "finished_ceiling_world_inches": 256.125,
  "beam_underside_world_inches": 246.5,
  "beam_top_world_inches": 256.125,
  "beam_depth_source_class": "Retained9.625in coordination envelope between108.5in source underside and118.125in R1ceiling. Exact dressed beam/top/lining junction remains unconfirmed.",
  "knee_wall_height_inches": 48,
  "knee_source_reading": {
    "page": 87,
    "crop_bbox_pdf": [
      1440,
      1330,
      1755,
      1600
    ],
    "text": "CW 1 1219 4' - 0\" SCREEN SCREEN SCREEN VERTICAL SIDING"
  },
  "beam_source_reading": {
    "page": 89,
    "crop_bbox_pdf": [
      130,
      275,
      235,
      305
    ],
    "text": "U/S of Beam Muskoka Room 9' - 0 1/2\" (2.756 m)"
  },
  "supports": [
    {
      "tag": "T1",
      "footprint_world_inches": [
        724.0000065104167,
        268.6400325520833,
        731.5200260416667,
        276.0799739583333
      ],
      "nominal_source_section_inches": [
        8,
        8
      ],
      "assembly_envelope_world_Z_inches": [
        138,
        255.125
      ],
      "scheduled_total_cut_length_inches": 117.125,
      "quantity_type": "Source-traced overall timber assembly envelope; associated plate/joint split not represented. Not an exact dressed shaft.",
      "vertical_basis": "Main-level base is a retained nominal study datum; source cut length retained. Exact shaft/baseplate/notch/finish offsets remain unconfirmed.",
      "source_footprint": {
        "file": "assistant/rooms/interior_studies/2026-11-15-muskoka-structure-r25/primary-support-register-v1.json",
        "sha256": "982b635f43090f01d1b4a8b3139eb8756092a555b7c43290cc70334f601f8aa7"
      },
      "source_trace_uncertainty_inches": 0.67,
      "plate_joint_detail_verified": false,
      "owner_approval": null
    },
    {
      "tag": "T2",
      "footprint_world_inches": [
        758.0800032552083,
        268.6400325520833,
        765.6000227864583,
        276.0800146484375
      ],
      "nominal_source_section_inches": [
        8,
        8
      ],
      "assembly_envelope_world_Z_inches": [
        138,
        247.5
      ],
      "scheduled_total_cut_length_inches": 109.5,
      "quantity_type": "Source-traced overall timber assembly envelope; associated plate/joint split not represented. Not an exact dressed shaft.",
      "vertical_basis": "Main-level base is a retained nominal study datum; source cut length retained. Exact shaft/baseplate/notch/finish offsets remain unconfirmed.",
      "source_footprint": {
        "file": "assistant/rooms/interior_studies/2026-11-15-muskoka-structure-r25/primary-support-register-v1.json",
        "sha256": "982b635f43090f01d1b4a8b3139eb8756092a555b7c43290cc70334f601f8aa7"
      },
      "source_trace_uncertainty_inches": 0.67,
      "plate_joint_detail_verified": false,
      "owner_approval": null
    },
    {
      "tag": "T3",
      "footprint_world_inches": [
        837.440029296875,
        268.6400325520833,
        844.879970703125,
        276.0799739583333
      ],
      "nominal_source_section_inches": [
        8,
        8
      ],
      "assembly_envelope_world_Z_inches": [
        138,
        246.5
      ],
      "scheduled_total_cut_length_inches": 108.5,
      "quantity_type": "Source-traced overall timber assembly envelope; associated plate/joint split not represented. Not an exact dressed shaft.",
      "vertical_basis": "Main-level base is a retained nominal study datum; source cut length retained. Exact shaft/baseplate/notch/finish offsets remain unconfirmed.",
      "source_footprint": {
        "file": "assistant/rooms/interior_studies/2026-11-15-muskoka-structure-r25/primary-support-register-v1.json",
        "sha256": "982b635f43090f01d1b4a8b3139eb8756092a555b7c43290cc70334f601f8aa7"
      },
      "source_trace_uncertainty_inches": 0.67,
      "plate_joint_detail_verified": false,
      "owner_approval": null
    },
    {
      "tag": "T4",
      "footprint_world_inches": [
        871.6000227864583,
        268.6400325520833,
        879.1199609375,
        276.0799739583333
      ],
      "nominal_source_section_inches": [
        8,
        8
      ],
      "assembly_envelope_world_Z_inches": [
        0,
        246.5
      ],
      "scheduled_total_cut_length_inches": 246.5,
      "quantity_type": "Source-traced overall timber assembly envelope; associated plate/joint split not represented. Not an exact dressed shaft.",
      "vertical_basis": "A300section corroborates lower pier/slab datum to108.5in main-level beam underside; source total246.5in.",
      "source_footprint": {
        "file": "assistant/rooms/interior_studies/2026-11-15-muskoka-structure-r25/primary-support-register-v1.json",
        "sha256": "982b635f43090f01d1b4a8b3139eb8756092a555b7c43290cc70334f601f8aa7"
      },
      "source_trace_uncertainty_inches": 0.67,
      "plate_joint_detail_verified": false,
      "owner_approval": null
    },
    {
      "tag": "T7",
      "footprint_world_inches": [
        871.6000227864583,
        414.8000260416666,
        879.1199609375,
        422.3199641927083
      ],
      "nominal_source_section_inches": [
        8,
        8
      ],
      "assembly_envelope_world_Z_inches": [
        0,
        246.5
      ],
      "scheduled_total_cut_length_inches": 246.5,
      "quantity_type": "Source-traced overall timber assembly envelope; associated plate/joint split not represented. Not an exact dressed shaft.",
      "vertical_basis": "A300section corroborates lower pier/slab datum to108.5in main-level beam underside; source total246.5in.",
      "source_footprint": {
        "file": "assistant/rooms/interior_studies/2026-11-15-muskoka-structure-r25/primary-support-register-v1.json",
        "sha256": "982b635f43090f01d1b4a8b3139eb8756092a555b7c43290cc70334f601f8aa7"
      },
      "source_trace_uncertainty_inches": 0.67,
      "plate_joint_detail_verified": false,
      "owner_approval": null
    },
    {
      "tag": "T8",
      "footprint_world_inches": [
        724.399990234375,
        414.8000260416666,
        731.8400130208333,
        422.3199641927083
      ],
      "nominal_source_section_inches": [
        8,
        8
      ],
      "assembly_envelope_world_Z_inches": [
        138,
        256.125
      ],
      "scheduled_total_cut_length_inches": 118.125,
      "quantity_type": "Source-traced overall timber assembly envelope; associated plate/joint split not represented. Not an exact dressed shaft.",
      "vertical_basis": "Main-level base is a retained nominal study datum; source cut length retained. Exact shaft/baseplate/notch/finish offsets remain unconfirmed.",
      "source_footprint": {
        "file": "assistant/rooms/interior_studies/2026-11-15-muskoka-structure-r25/primary-support-register-v1.json",
        "sha256": "982b635f43090f01d1b4a8b3139eb8756092a555b7c43290cc70334f601f8aa7"
      },
      "source_trace_uncertainty_inches": 0.67,
      "plate_joint_detail_verified": false,
      "owner_approval": null
    }
  ],
  "screen_system": "Primary elevations label SCREEN. Model uses thin schematic infill surfaces; no glass thickness or supplied weatherwall product is claimed.",
  "single_door": {
    "leaf_width_inches": 36,
    "leaf_height_inches": 84,
    "source_direction": "Later single swinging door/collapsible screen supersedes historical slider.",
    "along_centre_inches": 790.16,
    "opening_outer_x_inches": [
      771.41,
      808.91
    ],
    "opening_head_world_inches": 223,
    "normal_translation_inches": -1.8199999999999932,
    "status": "All size/profile/position/80degree swing remain estimated; no supplier installation approval."
  },
  "roof": "Current R1roof geometry retained, pending complete roof-layer/member/overhang/detail qualification.",
  "whole_model_qualified": false,
  "image_generation_allowed": false,
  "owner_approval": null,
  "shared_opening": "E101-programme-v26.json"
}