{"revision":"R26-v23-interior-door-programme","rows":[{"tag":"I001","room":"mechanical-room","level":"basement","wall":"hall-bath-north","axis":1,"along_axis":0,"along_centre_inches":221.16,"wall_normal_bounds_inches":[201.51,206.01],"nominal_width_inches":36.0,"nominal_height_inches":84.0,"operation_code":1,"operation":"single swing","source":{"file":"docs/Drive_Sync/07_PERMITS/BP-2026-0678 Building Permit (Issued 2026-08-20).pdf","sha256":"ec9f327ed22e13252c42b577145b501c045caa65aa4a13bd8161fa8ed98d706d","page":85,"primary_text":"I-001\nProposed T/O Slab\nSingle Swing Interior Door\n36\"\n84\""},"later_change":null,"nominal_dimension_scope":"Scheduled nominal door/panel programme. Double equal-leaf allocation is inferred. These are not supplier rough openings or certified installed clear passages.","rough_outline_along_z_inches":[202.035,0,240.285,85.625],"base_world_inches":0,"estimates":{"panel_thickness_inches":1.375,"floor_undercut_inches":0.5,"side_gap_each_inches":0.125,"head_gap_inches":0.125,"jamb_thickness_inches":0.75,"shim_each_inches":0.25,"casing_face_width_inches":2.25,"casing_projection_inches":0.375,"hinge_and_setout":"Proposed current wall-face installation using inherited source-traced along centre; +/-0.67in source-trace uncertainty. Handedness is estimated from the drawing and remains reviewable.","rough_opening":"Explicit inferred installation reservation, not a supplier/order/structural dimension. Final products may change it."},"owner_approval":null,"registered_source_jambs":{"page":84,"axis":1,"along_PDF":[598.44,652.56],"source_drawn_width_inches":36.07999999999993,"centre_inches":221.16,"previous_wall":"bath-east","previous_axis_pdf":[663.9,493.5],"scope":"Registered primary drawing jamb extents; +/-0.67in trace uncertainty, not surveyed set-out. Source nominal panel dimensions and inferred installation reservation remain distinct."},"hinge_end":"high","open_normal_direction":-1},{"tag":"I002","room":"bedroom4","level":"basement","wall":"bed4-hall","axis":0,"along_axis":1,"along_centre_inches":227.0,"wall_normal_bounds_inches":[193.35,197.85],"nominal_width_inches":30.0,"nominal_height_inches":84.0,"operation_code":1,"operation":"single swing","source":{"file":"docs/Drive_Sync/07_PERMITS/BP-2026-0678 Building Permit (Issued 2026-08-20).pdf","sha256":"ec9f327ed22e13252c42b577145b501c045caa65aa4a13bd8161fa8ed98d706d","page":85,"primary_text":"I-002\nProposed T/O Slab\nSingle Swing Interior Door\n30\"\n84\""},"later_change":null,"nominal_dimension_scope":"Scheduled nominal door/panel programme. Double equal-leaf allocation is inferred. These are not supplier rough openings or certified installed clear passages.","rough_outline_along_z_inches":[210.875,0,243.125,85.625],"base_world_inches":0,"estimates":{"panel_thickness_inches":1.375,"floor_undercut_inches":0.5,"side_gap_each_inches":0.125,"head_gap_inches":0.125,"jamb_thickness_inches":0.75,"shim_each_inches":0.25,"casing_face_width_inches":2.25,"casing_projection_inches":0.375,"hinge_and_setout":"Proposed current wall-face installation using inherited source-traced along centre; +/-0.67in source-trace uncertainty. Handedness is estimated from the drawing and remains reviewable.","rough_opening":"Explicit inferred installation reservation, not a supplier/order/structural dimension. Final products may change it."},"owner_approval":null,"registered_source_jambs":{"page":84,"axis":0,"along_PDF":[537.84,582.84],"source_drawn_width_inches":30.0,"centre_inches":227.0,"previous_wall":"bed4-hall","previous_axis_pdf":[587.16,551],"scope":"Registered primary drawing jamb extents; +/-0.67in trace uncertainty, not surveyed set-out. Source nominal panel dimensions and inferred installation reservation remain distinct."},"hinge_end":"high","open_normal_direction":-1},{"tag":"I003","room":"bedroom4","level":"basement","wall":"bed4-alcove","axis":0,"along_axis":1,"along_centre_inches":275.59999999999997,"wall_normal_bounds_inches":[193.35,197.85],"nominal_width_inches":36.0,"nominal_height_inches":84.0,"operation_code":3,"operation":"double swing","source":{"file":"docs/Drive_Sync/07_PERMITS/BP-2026-0678 Building Permit (Issued 2026-08-20).pdf","sha256":"ec9f327ed22e13252c42b577145b501c045caa65aa4a13bd8161fa8ed98d706d","page":85,"primary_text":"I-003\nProposed T/O Slab\nDouble Swing 2 Panel Interior Door\n36\"\n84\""},"later_change":null,"nominal_dimension_scope":"Scheduled nominal door/panel programme. Double equal-leaf allocation is inferred. These are not supplier rough openings or certified installed clear passages.","rough_outline_along_z_inches":[256.47499999999997,0,294.72499999999997,85.625],"base_world_inches":0,"estimates":{"panel_thickness_inches":1.375,"floor_undercut_inches":0.5,"side_gap_each_inches":0.125,"head_gap_inches":0.125,"jamb_thickness_inches":0.75,"shim_each_inches":0.25,"casing_face_width_inches":2.25,"casing_projection_inches":0.375,"hinge_and_setout":"Proposed current wall-face installation using inherited source-traced along centre; +/-0.67in source-trace uncertainty. Handedness is estimated from the drawing and remains reviewable.","rough_opening":"Explicit inferred installation reservation, not a supplier/order/structural dimension. Final products may change it."},"owner_approval":null,"registered_source_jambs":{"page":84,"axis":0,"along_PDF":[606.24,660.24],"source_drawn_width_inches":36.0,"centre_inches":275.59999999999997,"previous_wall":"bed4-alcove","previous_axis_pdf":[585.66,634.56],"scope":"Registered primary drawing jamb extents; +/-0.67in trace uncertainty, not surveyed set-out. Source nominal panel dimensions and inferred installation reservation remain distinct."},"hinge_end":"both","open_normal_direction":-1},{"tag":"I004","room":"basement-hall","level":"basement","wall":"wing-hall","axis":0,"along_axis":1,"along_centre_inches":269.0,"wall_normal_bounds_inches":[251.73000000000002,258.23],"nominal_width_inches":30.0,"nominal_height_inches":84.0,"operation_code":1,"operation":"single swing","source":{"file":"docs/Drive_Sync/07_PERMITS/BP-2026-0678 Building Permit (Issued 2026-08-20).pdf","sha256":"ec9f327ed22e13252c42b577145b501c045caa65aa4a13bd8161fa8ed98d706d","page":85,"primary_text":"I-004\nProposed T/O Slab\nSingle Swing Interior Door\n30\"\n84\""},"later_change":null,"nominal_dimension_scope":"Scheduled nominal door/panel programme. Double equal-leaf allocation is inferred. These are not supplier rough openings or certified installed clear passages.","rough_outline_along_z_inches":[252.875,0,285.125,85.625],"base_world_inches":0,"estimates":{"panel_thickness_inches":1.375,"floor_undercut_inches":0.5,"side_gap_each_inches":0.125,"head_gap_inches":0.125,"jamb_thickness_inches":0.75,"shim_each_inches":0.25,"casing_face_width_inches":2.25,"casing_projection_inches":0.375,"hinge_and_setout":"Proposed current wall-face installation using inherited source-traced along centre; +/-0.67in source-trace uncertainty. Handedness is estimated from the drawing and remains reviewable.","rough_opening":"Explicit inferred installation reservation, not a supplier/order/structural dimension. Final products may change it."},"owner_approval":null,"registered_source_jambs":{"page":84,"axis":0,"along_PDF":[600.84,645.84],"source_drawn_width_inches":30.0,"centre_inches":269.0,"previous_wall":"wing-hall","previous_axis_pdf":[676.38,625],"scope":"Registered primary drawing jamb extents; +/-0.67in trace uncertainty, not surveyed set-out. Source nominal panel dimensions and inferred installation reservation remain distinct."},"source_operation_correction":"A101 shows laundry-chute/hamper access opening east into stair/hall; not an inward bedroom wardrobe door. Source swing direction retained; installed profile/hinge axis remains estimated.","hinge_end":"low","open_normal_direction":1},{"tag":"I005","room":"ensuite3","level":"basement","wall":"ensuite-bedroom3","axis":1,"along_axis":0,"along_centre_inches":63.52000000000002,"wall_normal_bounds_inches":[370.90000000000003,377.40000000000003],"nominal_width_inches":30.0,"nominal_height_inches":84.0,"operation_code":2,"operation":"pocket","source":{"file":"docs/Drive_Sync/07_PERMITS/BP-2026-0678 Building Permit (Issued 2026-08-20).pdf","sha256":"ec9f327ed22e13252c42b577145b501c045caa65aa4a13bd8161fa8ed98d706d","page":85,"primary_text":"I-005\nProposed T/O Slab\nPocket, Single Panel Interior Door\n30\"\n84\""},"later_change":null,"nominal_dimension_scope":"Scheduled nominal door/panel programme. Double equal-leaf allocation is inferred. These are not supplier rough openings or certified installed clear passages.","rough_outline_along_z_inches":[47.39500000000002,0,79.64500000000001,87.625],"base_world_inches":0,"estimates":{"panel_thickness_inches":1.375,"floor_undercut_inches":0.5,"side_gap_each_inches":0.125,"head_gap_inches":0.125,"jamb_thickness_inches":0.75,"shim_each_inches":0.25,"casing_face_width_inches":2.25,"casing_projection_inches":0.375,"hinge_and_setout":"Proposed current wall-face installation using inherited source-traced along centre; +/-0.67in source-trace uncertainty. Handedness is estimated from the drawing and remains reviewable.","rough_opening":"Explicit inferred installation reservation, not a supplier/order/structural dimension. Final products may change it."},"owner_approval":null,"registered_source_jambs":{"page":84,"axis":1,"along_PDF":[366.48,411.6],"source_drawn_width_inches":30.080000000000002,"centre_inches":63.52000000000002,"previous_wall":"ensuite-bedroom3","previous_axis_pdf":[420,780.3],"scope":"Registered primary drawing jamb extents; +/-0.67in trace uncertainty, not surveyed set-out. Source nominal panel dimensions and inferred installation reservation remain distinct."},"source_operation_correction":"A101 pocket frame is east/right of the30in opening; pocket travel is positive X. Earlier inherited axis was a displaced label, not the opening centre.","pocket_direction":1,"default_translation_inches":30.125,"pocket_cavity_half_depth_inches":1.125,"pocket_cavity_along_inches":[78.64500000000001,108.89500000000001],"pocket_direction_source_class":"Drawing-based estimated direction; final pocket frame/track/structure remains unresolved."},{"tag":"I006","room":"basement-wic","level":"basement","wall":"ensuite-bedroom3","axis":1,"along_axis":0,"along_centre_inches":230.84,"wall_normal_bounds_inches":[370.90000000000003,377.40000000000003],"nominal_width_inches":30.0,"nominal_height_inches":84.0,"operation_code":1,"operation":"single swing","source":{"file":"docs/Drive_Sync/07_PERMITS/BP-2026-0678 Building Permit (Issued 2026-08-20).pdf","sha256":"ec9f327ed22e13252c42b577145b501c045caa65aa4a13bd8161fa8ed98d706d","page":85,"primary_text":"I-006\nProposed T/O Slab\nSingle Swing Interior Door\n30\"\n84\""},"later_change":null,"nominal_dimension_scope":"Scheduled nominal door/panel programme. Double equal-leaf allocation is inferred. These are not supplier rough openings or certified installed clear passages.","rough_outline_along_z_inches":[214.715,0,246.965,85.625],"base_world_inches":0,"estimates":{"panel_thickness_inches":1.375,"floor_undercut_inches":0.5,"side_gap_each_inches":0.125,"head_gap_inches":0.125,"jamb_thickness_inches":0.75,"shim_each_inches":0.25,"casing_face_width_inches":2.25,"casing_projection_inches":0.375,"hinge_and_setout":"Proposed current wall-face installation using inherited source-traced along centre; +/-0.67in source-trace uncertainty. Handedness is estimated from the drawing and remains reviewable.","rough_opening":"Explicit inferred installation reservation, not a supplier/order/structural dimension. Final products may change it."},"owner_approval":null,"registered_source_jambs":{"page":84,"axis":1,"along_PDF":[617.52,662.52],"source_drawn_width_inches":30.0,"centre_inches":230.84,"previous_wall":"ensuite-bedroom3","previous_axis_pdf":[640.02,780.3],"scope":"Registered primary drawing jamb extents; +/-0.67in trace uncertainty, not surveyed set-out. Source nominal panel dimensions and inferred installation reservation remain distinct."},"hinge_end":"high","open_normal_direction":-1},{"tag":"I007","room":"bedroom3","level":"basement","wall":"wing-hall","axis":0,"along_axis":1,"along_centre_inches":435.32,"wall_normal_bounds_inches":[251.73000000000002,258.23],"nominal_width_inches":30.0,"nominal_height_inches":96.0,"operation_code":1,"operation":"single swing","source":{"file":"docs/Drive_Sync/07_PERMITS/BP-2026-0678 Building Permit (Issued 2026-08-20).pdf","sha256":"ec9f327ed22e13252c42b577145b501c045caa65aa4a13bd8161fa8ed98d706d","page":85,"primary_text":"I-007\nProposed T/O Slab\nSingle Swing Interior Door\n30\"\n96\""},"later_change":null,"nominal_dimension_scope":"Scheduled nominal door/panel programme. Double equal-leaf allocation is inferred. These are not supplier rough openings or certified installed clear passages.","rough_outline_along_z_inches":[419.195,0,451.445,97.625],"base_world_inches":0,"estimates":{"panel_thickness_inches":1.375,"floor_undercut_inches":0.5,"side_gap_each_inches":0.125,"head_gap_inches":0.125,"jamb_thickness_inches":0.75,"shim_each_inches":0.25,"casing_face_width_inches":2.25,"casing_projection_inches":0.375,"hinge_and_setout":"Proposed current wall-face installation using inherited source-traced along centre; +/-0.67in source-trace uncertainty. Handedness is estimated from the drawing and remains reviewable.","rough_opening":"Explicit inferred installation reservation, not a supplier/order/structural dimension. Final products may change it."},"owner_approval":null,"registered_source_jambs":{"page":84,"axis":0,"along_PDF":[850.32,895.32],"source_drawn_width_inches":30.0,"centre_inches":435.32,"previous_wall":"wing-hall","previous_axis_pdf":[676.38,872.82],"scope":"Registered primary drawing jamb extents; +/-0.67in trace uncertainty, not surveyed set-out. Source nominal panel dimensions and inferred installation reservation remain distinct."},"hinge_end":"low","open_normal_direction":-1},{"tag":"I009","room":"basement-bathroom","level":"basement","wall":"hall-bath-north","axis":1,"along_axis":0,"along_centre_inches":326.12000000000006,"wall_normal_bounds_inches":[201.51,206.01],"nominal_width_inches":30.0,"nominal_height_inches":84.0,"operation_code":1,"operation":"single swing","source":{"file":"docs/Drive_Sync/07_PERMITS/BP-2026-0678 Building Permit (Issued 2026-08-20).pdf","sha256":"ec9f327ed22e13252c42b577145b501c045caa65aa4a13bd8161fa8ed98d706d","page":85,"primary_text":"I-009\nProposed T/O Slab\nSingle Swing Interior Door\n30\"\n84\""},"later_change":null,"nominal_dimension_scope":"Scheduled nominal door/panel programme. Double equal-leaf allocation is inferred. These are not supplier rough openings or certified installed clear passages.","rough_outline_along_z_inches":[309.99500000000006,0,342.24500000000006,85.625],"base_world_inches":0,"estimates":{"panel_thickness_inches":1.375,"floor_undercut_inches":0.5,"side_gap_each_inches":0.125,"head_gap_inches":0.125,"jamb_thickness_inches":0.75,"shim_each_inches":0.25,"casing_face_width_inches":2.25,"casing_projection_inches":0.375,"hinge_and_setout":"Proposed current wall-face installation using inherited source-traced along centre; +/-0.67in source-trace uncertainty. Handedness is estimated from the drawing and remains reviewable.","rough_opening":"Explicit inferred installation reservation, not a supplier/order/structural dimension. Final products may change it."},"owner_approval":null,"registered_source_jambs":{"page":84,"axis":1,"along_PDF":[760.44,805.44],"source_drawn_width_inches":30.0,"centre_inches":326.12000000000006,"previous_wall":"hall-bath-north","previous_axis_pdf":[782,525.48],"scope":"Registered primary drawing jamb extents; +/-0.67in trace uncertainty, not surveyed set-out. Source nominal panel dimensions and inferred installation reservation remain distinct."},"hinge_end":"high","open_normal_direction":-1},{"tag":"I010","room":"media-room","level":"basement","wall":"media-rec","axis":1,"along_axis":0,"along_centre_inches":613.2399999999999,"wall_normal_bounds_inches":[272.02500000000003,278.52500000000003],"nominal_width_inches":84.0,"nominal_height_inches":84.0,"operation_code":3,"operation":"double swing","source":{"file":"docs/Drive_Sync/07_PERMITS/BP-2026-0678 Building Permit (Issued 2026-08-20).pdf","sha256":"ec9f327ed22e13252c42b577145b501c045caa65aa4a13bd8161fa8ed98d706d","page":85,"primary_text":"I-010\nProposed T/O Slab\nDouble Swing 2 Panel Interior Door\n84\"\n84\""},"later_change":null,"nominal_dimension_scope":"Scheduled nominal door/panel programme. Double equal-leaf allocation is inferred. These are not supplier rough openings or certified installed clear passages.","rough_outline_along_z_inches":[570.1149999999999,0,656.3649999999999,85.875],"base_world_inches":0,"estimates":{"panel_thickness_inches":1.375,"floor_undercut_inches":0.75,"side_gap_each_inches":0.125,"head_gap_inches":0.125,"jamb_thickness_inches":0.75,"shim_each_inches":0.25,"casing_face_width_inches":2.25,"casing_projection_inches":0.375,"hinge_and_setout":"Proposed current wall-face installation using inherited source-traced along centre; +/-0.67in source-trace uncertainty. Handedness is estimated from the drawing and remains reviewable.","rough_opening":"Explicit inferred installation reservation, not a supplier/order/structural dimension. Final products may change it."},"owner_approval":null,"registered_source_jambs":{"page":84,"axis":1,"along_PDF":[1150.56,1276.68],"source_drawn_width_inches":84.08000000000008,"centre_inches":613.2399999999999,"previous_wall":"media-rec","previous_axis_pdf":[1213.66,632.94],"scope":"Registered primary drawing jamb extents; +/-0.67in trace uncertainty, not surveyed set-out. Source nominal panel dimensions and inferred installation reservation remain distinct."},"floor_clearance_estimate":"Proposed0.75in undercut preserves both84in panels and clears the unchanged0.52in modeled half-inch turf proxy by0.23in. Final mat, floor, hardware and acoustic/ventilation requirements remain unselected.","hinge_end":"both","open_normal_direction":-1},{"tag":"I011","room":"basement-laundry","level":"basement","wall":"laundry-north","axis":1,"along_axis":0,"along_centre_inches":461.52250000000004,"wall_normal_bounds_inches":[272.02500000000003,278.52500000000003],"nominal_width_inches":34.0,"nominal_height_inches":84.0,"operation_code":2,"operation":"pocket","source":{"file":"docs/Drive_Sync/07_PERMITS/BP-2026-0678 Building Permit (Issued 2026-08-20).pdf","sha256":"ec9f327ed22e13252c42b577145b501c045caa65aa4a13bd8161fa8ed98d706d","page":85,"primary_text":"I-011\nProposed T/O Slab\nPocket, Single Panel Interior Door\n34\"\n84\""},"later_change":null,"nominal_dimension_scope":"Scheduled nominal door/panel programme. Double equal-leaf allocation is inferred. These are not supplier rough openings or certified installed clear passages.","rough_outline_along_z_inches":[409.27250000000004,0,479.64750000000004,87.625],"base_world_inches":0,"estimates":{"panel_thickness_inches":1.375,"floor_undercut_inches":0.5,"side_gap_each_inches":0.125,"head_gap_inches":0.125,"jamb_thickness_inches":0.75,"shim_each_inches":0.25,"casing_face_width_inches":2.25,"casing_projection_inches":0.375,"hinge_and_setout":"Proposed current wall-face installation using inherited source-traced along centre; +/-0.67in source-trace uncertainty. Handedness is estimated from the drawing and remains reviewable.","rough_opening":"Explicit inferred installation reservation, not a supplier/order/structural dimension. Final products may change it."},"owner_approval":null,"pocket_direction":1,"default_translation_inches":34.125,"pocket_cavity_half_depth_inches":1.125,"pocket_cavity_along_inches":[478.64750000000004,512.8975],"pocket_direction_source_class":"Drawing-based estimated direction; final pocket frame/track/structure remains unresolved.","source_traced_along_centre_inches":461.96000000000004,"estimated_setout_adjustment_inches":-0.4375,"shared_frame_group":"I011-I012","shared_meeting_gap_inches":0.125,"shared_frame_basis":"Two source-scheduled pocket leaves meeting in one inferred perimeter frame, no centre post. Half-inch pair set-out correction keeps the full-sized parked panels/linings inside the retained wall; not a supplier or framing approval.","shared_panel_outer_bounds_inches":[410.39750000000004,478.52250000000004],"shared_jamb_clear_width_inches":68.375},{"tag":"I012","room":"basement-laundry","level":"basement","wall":"laundry-north","axis":1,"along_axis":0,"along_centre_inches":427.39750000000004,"wall_normal_bounds_inches":[272.02500000000003,278.52500000000003],"nominal_width_inches":34.0,"nominal_height_inches":84.0,"operation_code":2,"operation":"pocket","source":{"file":"docs/Drive_Sync/07_PERMITS/BP-2026-0678 Building Permit (Issued 2026-08-20).pdf","sha256":"ec9f327ed22e13252c42b577145b501c045caa65aa4a13bd8161fa8ed98d706d","page":85,"primary_text":"I-012\nProposed T/O Slab\nPocket, Single Panel Interior Door\n34\"\n84\""},"later_change":null,"nominal_dimension_scope":"Scheduled nominal door/panel programme. Double equal-leaf allocation is inferred. These are not supplier rough openings or certified installed clear passages.","rough_outline_along_z_inches":[409.27250000000004,0,479.64750000000004,87.625],"base_world_inches":0,"estimates":{"panel_thickness_inches":1.375,"floor_undercut_inches":0.5,"side_gap_each_inches":0.125,"head_gap_inches":0.125,"jamb_thickness_inches":0.75,"shim_each_inches":0.25,"casing_face_width_inches":2.25,"casing_projection_inches":0.375,"hinge_and_setout":"Proposed current wall-face installation using inherited source-traced along centre; +/-0.67in source-trace uncertainty. Handedness is estimated from the drawing and remains reviewable.","rough_opening":"Explicit inferred installation reservation, not a supplier/order/structural dimension. Final products may change it."},"owner_approval":null,"pocket_direction":-1,"default_translation_inches":-34.125,"pocket_cavity_half_depth_inches":1.125,"pocket_cavity_along_inches":[376.02250000000004,410.27250000000004],"pocket_direction_source_class":"Drawing-based estimated direction; final pocket frame/track/structure remains unresolved.","source_traced_along_centre_inches":427.96000000000004,"estimated_setout_adjustment_inches":-0.5625,"shared_frame_group":"I011-I012","shared_meeting_gap_inches":0.125,"shared_frame_basis":"Two source-scheduled pocket leaves meeting in one inferred perimeter frame, no centre post. Half-inch pair set-out correction keeps the full-sized parked panels/linings inside the retained wall; not a supplier or framing approval.","shared_panel_outer_bounds_inches":[410.39750000000004,478.52250000000004],"shared_jamb_clear_width_inches":68.375},{"tag":"I100","room":"bedroom2","level":"main","wall":"bed2-south-partition","axis":1,"along_axis":0,"along_centre_inches":206.92,"wall_normal_bounds_inches":[187.85,194.35],"nominal_width_inches":30.0,"nominal_height_inches":96.0,"operation_code":2,"operation":"pocket","source":{"file":"docs/Drive_Sync/07_PERMITS/BP-2026-0678 Building Permit (Issued 2026-08-20).pdf","sha256":"ec9f327ed22e13252c42b577145b501c045caa65aa4a13bd8161fa8ed98d706d","page":85,"primary_text":"I-100\nProposed Main Level\nPocket, Single Panel Interior Door\n30\"\n96\""},"later_change":null,"nominal_dimension_scope":"Scheduled nominal door/panel programme. Double equal-leaf allocation is inferred. These are not supplier rough openings or certified installed clear passages.","rough_outline_along_z_inches":[190.795,138,223.045,237.625],"base_world_inches":138,"estimates":{"panel_thickness_inches":1.375,"floor_undercut_inches":0.5,"side_gap_each_inches":0.125,"head_gap_inches":0.125,"jamb_thickness_inches":0.75,"shim_each_inches":0.25,"casing_face_width_inches":2.25,"casing_projection_inches":0.375,"hinge_and_setout":"Proposed current wall-face installation using inherited source-traced along centre; +/-0.67in source-trace uncertainty. Handedness is estimated from the drawing and remains reviewable.","rough_opening":"Explicit inferred installation reservation, not a supplier/order/structural dimension. Final products may change it."},"owner_approval":null,"registered_source_jambs":{"page":85,"axis":1,"along_PDF":[581.64,626.64],"source_drawn_width_inches":30.0,"centre_inches":206.92,"previous_wall":"bed2-south-partition","previous_axis_pdf":[604.2,506.58000000000004],"scope":"Registered primary drawing jamb extents; +/-0.67in trace uncertainty, not surveyed set-out. Source nominal panel dimensions and inferred installation reservation remain distinct."},"pocket_direction":-1,"default_translation_inches":-30.125,"pocket_cavity_half_depth_inches":1.125,"pocket_cavity_along_inches":[161.545,191.795],"pocket_direction_source_class":"Drawing-based estimated direction; final pocket frame/track/structure remains unresolved."},{"tag":"I101","room":"primary-bathroom","level":"main","wall":"bath-hall-nov03","axis":0,"along_axis":1,"along_centre_inches":286.34999999999997,"wall_normal_bounds_inches":[181.35,185.85],"nominal_width_inches":30.0,"nominal_height_inches":96.0,"operation_code":1,"operation":"single swing","source":{"file":"docs/Drive_Sync/07_PERMITS/BP-2026-0678 Building Permit (Issued 2026-08-20).pdf","sha256":"ec9f327ed22e13252c42b577145b501c045caa65aa4a13bd8161fa8ed98d706d","page":85,"primary_text":"I-101\nProposed Main Level\nSingle Swing Interior Door\n30\"\n96\""},"later_change":null,"nominal_dimension_scope":"Scheduled nominal door/panel programme. Double equal-leaf allocation is inferred. These are not supplier rough openings or certified installed clear passages.","rough_outline_along_z_inches":[270.22499999999997,138,302.47499999999997,235.625],"base_world_inches":138,"estimates":{"panel_thickness_inches":1.375,"floor_undercut_inches":0.5,"side_gap_each_inches":0.125,"head_gap_inches":0.125,"jamb_thickness_inches":0.75,"shim_each_inches":0.25,"casing_face_width_inches":2.25,"casing_projection_inches":0.375,"hinge_and_setout":"Proposed current wall-face installation using inherited source-traced along centre; +/-0.67in source-trace uncertainty. Handedness is estimated from the drawing and remains reviewable.","rough_opening":"Explicit inferred installation reservation, not a supplier/order/structural dimension. Final products may change it."},"owner_approval":null,"hinge_end":"high","open_normal_direction":-1},{"tag":"I102","room":"primary-bathroom","level":"main","wall":"primary-WC-front","axis":1,"along_axis":0,"along_centre_inches":162.35,"wall_normal_bounds_inches":[260.84999999999997,265.34999999999997],"nominal_width_inches":28,"nominal_height_inches":96.0,"operation_code":1,"operation":"single swing","source":{"file":"docs/Drive_Sync/07_PERMITS/BP-2026-0678 Building Permit (Issued 2026-08-20).pdf","sha256":"ec9f327ed22e13252c42b577145b501c045caa65aa4a13bd8161fa8ed98d706d","page":85,"primary_text":"I-102\nProposed Main Level\nSingle Swing Interior Door\n24\"\n96\""},"later_change":{"file":"docs/Drive_Sync/05_COMMUNICATIONS_LOG/SD26-0309 Carothers Cottage - Proposed Primary Ensuite - 03NOV26.pdf","width_inches":28,"height_class":"Retained96in design estimate; no later printed height supplied."},"nominal_dimension_scope":"Scheduled nominal door/panel programme. Double equal-leaf allocation is inferred. These are not supplier rough openings or certified installed clear passages.","rough_outline_along_z_inches":[147.225,138,177.475,235.625],"base_world_inches":138,"estimates":{"panel_thickness_inches":1.375,"floor_undercut_inches":0.5,"side_gap_each_inches":0.125,"head_gap_inches":0.125,"jamb_thickness_inches":0.75,"shim_each_inches":0.25,"casing_face_width_inches":2.25,"casing_projection_inches":0.375,"hinge_and_setout":"Proposed current wall-face installation using inherited source-traced along centre; +/-0.67in source-trace uncertainty. Handedness is estimated from the drawing and remains reviewable.","rough_opening":"Explicit inferred installation reservation, not a supplier/order/structural dimension. Final products may change it."},"owner_approval":null,"hinge_end":"high","open_normal_direction":-1},{"tag":"I103","room":"bedroom1","level":"main","wall":"bed1-south-partition","axis":1,"along_axis":0,"along_centre_inches":206.92,"wall_normal_bounds_inches":[332.46999999999997,338.96999999999997],"nominal_width_inches":30.0,"nominal_height_inches":96.0,"operation_code":2,"operation":"pocket","source":{"file":"docs/Drive_Sync/07_PERMITS/BP-2026-0678 Building Permit (Issued 2026-08-20).pdf","sha256":"ec9f327ed22e13252c42b577145b501c045caa65aa4a13bd8161fa8ed98d706d","page":85,"primary_text":"I-103\nProposed Main Level\nPocket, Single Panel Interior Door\n30\"\n96\""},"later_change":null,"nominal_dimension_scope":"Scheduled nominal door/panel programme. Double equal-leaf allocation is inferred. These are not supplier rough openings or certified installed clear passages.","rough_outline_along_z_inches":[190.795,138,223.045,237.625],"base_world_inches":138,"estimates":{"panel_thickness_inches":1.375,"floor_undercut_inches":0.5,"side_gap_each_inches":0.125,"head_gap_inches":0.125,"jamb_thickness_inches":0.75,"shim_each_inches":0.25,"casing_face_width_inches":2.25,"casing_projection_inches":0.375,"hinge_and_setout":"Proposed current wall-face installation using inherited source-traced along centre; +/-0.67in source-trace uncertainty. Handedness is estimated from the drawing and remains reviewable.","rough_opening":"Explicit inferred installation reservation, not a supplier/order/structural dimension. Final products may change it."},"owner_approval":null,"registered_source_jambs":{"page":85,"axis":1,"along_PDF":[581.64,626.64],"source_drawn_width_inches":30.0,"centre_inches":206.92,"previous_wall":"bed1-south-partition","previous_axis_pdf":[604.2,723.42],"scope":"Registered primary drawing jamb extents; +/-0.67in trace uncertainty, not surveyed set-out. Source nominal panel dimensions and inferred installation reservation remain distinct."},"pocket_direction":-1,"default_translation_inches":-30.125,"pocket_cavity_half_depth_inches":1.125,"pocket_cavity_along_inches":[161.545,191.795],"pocket_direction_source_class":"Drawing-based estimated direction; final pocket frame/track/structure remains unresolved."},{"tag":"I104","room":"main-hall","level":"main","wall":"hall-west","axis":0,"along_axis":1,"along_centre_inches":217.71999999999994,"wall_normal_bounds_inches":[251.725,258.2250000000001],"nominal_width_inches":30.0,"nominal_height_inches":96.0,"operation_code":2,"operation":"pocket","source":{"file":"docs/Drive_Sync/07_PERMITS/BP-2026-0678 Building Permit (Issued 2026-08-20).pdf","sha256":"ec9f327ed22e13252c42b577145b501c045caa65aa4a13bd8161fa8ed98d706d","page":85,"primary_text":"I-104\nProposed Main Level\nPocket, Single Panel Interior Door\n30\"\n96\""},"later_change":null,"nominal_dimension_scope":"Scheduled nominal door/panel programme. Double equal-leaf allocation is inferred. These are not supplier rough openings or certified installed clear passages.","rough_outline_along_z_inches":[201.59499999999994,138,233.84499999999994,237.625],"base_world_inches":138,"estimates":{"panel_thickness_inches":1.375,"floor_undercut_inches":0.5,"side_gap_each_inches":0.125,"head_gap_inches":0.125,"jamb_thickness_inches":0.75,"shim_each_inches":0.25,"casing_face_width_inches":2.25,"casing_projection_inches":0.375,"hinge_and_setout":"Proposed current wall-face installation using inherited source-traced along centre; +/-0.67in source-trace uncertainty. Handedness is estimated from the drawing and remains reviewable.","rough_opening":"Explicit inferred installation reservation, not a supplier/order/structural dimension. Final products may change it."},"owner_approval":null,"registered_source_jambs":{"page":85,"axis":0,"along_PDF":[523.92,568.92],"source_drawn_width_inches":30.0,"centre_inches":217.71999999999994,"previous_wall":"hall-west","previous_axis_pdf":[676.62,552.9],"scope":"Registered primary drawing jamb extents; +/-0.67in trace uncertainty, not surveyed set-out. Source nominal panel dimensions and inferred installation reservation remain distinct."},"pocket_direction":1,"default_translation_inches":30.125,"pocket_cavity_half_depth_inches":1.125,"pocket_cavity_along_inches":[232.84499999999994,263.0949999999999],"pocket_direction_source_class":"Drawing-based estimated direction; final pocket frame/track/structure remains unresolved."},{"tag":"I105","room":"powder-room","level":"main","wall":"powder-north","axis":1,"along_axis":0,"along_centre_inches":301.8,"wall_normal_bounds_inches":[189.91,194.41],"nominal_width_inches":30.0,"nominal_height_inches":96.0,"operation_code":1,"operation":"single swing","source":{"file":"docs/Drive_Sync/07_PERMITS/BP-2026-0678 Building Permit (Issued 2026-08-20).pdf","sha256":"ec9f327ed22e13252c42b577145b501c045caa65aa4a13bd8161fa8ed98d706d","page":85,"primary_text":"I-105\nProposed Main Level\nSingle Swing Interior Door\n30\"\n96\""},"later_change":null,"nominal_dimension_scope":"Scheduled nominal door/panel programme. Double equal-leaf allocation is inferred. These are not supplier rough openings or certified installed clear passages.","rough_outline_along_z_inches":[285.675,138,317.925,235.625],"base_world_inches":138,"estimates":{"panel_thickness_inches":1.375,"floor_undercut_inches":0.5,"side_gap_each_inches":0.125,"head_gap_inches":0.125,"jamb_thickness_inches":0.75,"shim_each_inches":0.25,"casing_face_width_inches":2.25,"casing_projection_inches":0.375,"hinge_and_setout":"Proposed current wall-face installation using inherited source-traced along centre; +/-0.67in source-trace uncertainty. Handedness is estimated from the drawing and remains reviewable.","rough_opening":"Explicit inferred installation reservation, not a supplier/order/structural dimension. Final products may change it."},"owner_approval":null,"source_setout_correction":{"previous_axis_centre_inches":288.96000000000004,"corrected_along_centre_inches":301.8,"PDF_jamb_x":[723.96,768.96],"PDF_wall_y":[504.72,511.44],"primary_vertical_jamb_segments":[[768.9600219726562,504.72003173828125,505.44000244140625],[768.9600219726562,505.44000244140625,510.72003173828125],[768.9600219726562,510.72003173828125,511.44000244140625],[723.9600219726562,510.72003173828125,511.44000244140625],[723.9600219726562,505.44000244140625,510.72003173828125],[723.9600219726562,504.72003173828125,505.44000244140625]],"scope":"Source-drawing registration, not an owner relocation or field set-out. Actual30in opening replaces a12.84in displaced inherited axis."},"registered_source_jambs":{"page":85,"axis":1,"along_PDF":[723.96,768.96],"source_drawn_width_inches":30.0,"centre_inches":301.8,"previous_wall":"powder-north","previous_axis_pdf":[727.2,508.08000000000004],"scope":"Registered primary drawing jamb extents; +/-0.67in trace uncertainty, not surveyed set-out. Source nominal panel dimensions and inferred installation reservation remain distinct."},"hinge_end":"high","open_normal_direction":-1}],"source_coverage":{"permit_pages_one_based":[84,85,86,87,88,89,95,96,98],"later_primary_bathroom_page":1,"physical_door_units":17,"unframed_entries":4},"estimation_policy":"All non-scheduled installation dimensions, hinge/track/set-out and hardware shapes are labelled estimates. No final selection, installed clear-width or structural compliance is claimed.","source_correction":"Prior source-closure supplement assigned I110 to entry/kitchen. A102tag atPDF[811..886,868..886] locates I110 at the nook passage, not entry. Its current ceiling is R1, not the proposed kitchen/entry plane.","image_generation_allowed":false,"owner_approval":null}