{
  "scope": "Required qualification of the R26 correction candidate, source-plan-v2 and full-plan-v1. This register clarifies the particular assignments/placements separately from sourced nominal dimensions.",
  "details": [
    {"item": "13 generic main-floor wall type assignments", "sourced": "E1, I1.2 and I2 nominal assembly widths/layers are printed on A102; core and finish edges are located in the primary plan.", "inferred": "Exterior-role/core-width classification supplies the working wall-by-wall assignments. Complete confirmation of every particular wall's printed type label and later change is still pending. Agreement with a chosen nominal width is not source acceptance of that assignment."},
    {"item": "Wall/frame positions", "sourced": "Printed Bedroom2 clear219.875x156in chains, nominal framing and gypsum layers; registered primary vector witnesses.", "inferred": "Scaled drawing positions and assembly joins use0.125in reading uncertainty; no field/survey set-out claimed. Other room chains and basement finish layers remain incomplete."},
    {"item": "Steel and timber connection", "sourced": "S200member types/top heights and actual7.5x9.5in timber; S301requires a nailer.", "inferred": "Retained plan centrelines/end positions await full plan audit. The1.5in minimum tapered nailer, resulting timber bearing plane, plate/body separation and connection details are illustrative. Never lower scheduled steel to fit this assumption. Engineering/finish/services remain held."},
    {"item": "Curtain banks", "sourced": "Later63.5mm vertical frame separation, marked bank profiles/stack dimensions and supplier4.5in frame depth.", "inferred": "Bank centres, lower frames at nominal floor and mounting depth remain the working placement.589mm central-gap interpretation, current tagged order and RSO/frame/glass datums are unconfirmed. Rounded shop profiles do not redefine the exact1:12roof plane."},
    {"item": "Frame/coupler and glazing detail", "sourced": "Supplier lower5mm/upper4mm glass and lower1in IGU notes.", "inferred": "1.5in visible frame/coupler sections and upper1in unit separation are illustrative. Exact supplier sightlines, seals and profiles are unavailable. These closed diagram components are not fabricated window details."},
    {"item": "Owned matching JH501 pair", "sourced": "Published early cane-backed63x53x76cm, seat43cm and arm69cm, adopted under direct owner instruction.", "inferred": "Cane/timber sections and crest profile follow the owner photo. The seat datum is modeled at the upper woven surface and arm datum at the front tip. Detailed manufacturer datum drawing and pair-specific dimensions are not supplied. This is a nominal design reconstruction, not authentication/fabrication geometry."},
    {"item": "Bathroom registration", "sourced": "Later Nov3I104 internal design and newly distinguished A102 finish-origin controls.", "inferred": "The0.49x0.43in registration adjustment uses nominal corrected finish origins. Internal geometry is translated without scaling; adjacent openings/installation and the complete source-space audit remain open."},
    {"item": "Floor/ceiling and property", "sourced": "Nominal main/basement design references and the independently registered R2 plane.", "inferred": "Finish-floor build-up, exact exposed timber/ceiling junction and field datum are not certified. Continuous finish flooring can extend below wall assemblies; clear room dimensions are measured between finished wall faces. No property survey/terrain/root registration is established."}
  ],
  "whole_model_measurement_gate": "held",
  "image_generation_allowed": false,
  "owner_approval": null,
  "engineering_approval": null
}
